Comparison of operator radiation exposure during coronary sinus catheter placement via the femoral or jugular vein approach

被引:11
作者
Chen, Wensheng [1 ,2 ,3 ]
Yao, Yan [1 ,2 ,3 ]
Zhang, Shu [1 ,2 ,3 ]
He, Ding Sheng [4 ]
机构
[1] Chinese Acad Med Sci, Peking Union Med Coll, Fuwai Hosp, Clin EP Lab, Beijing 100037, Peoples R China
[2] Chinese Acad Med Sci, Peking Union Med Coll, Fuwai Hosp, Arrhythmia Ctr, Beijing 100037, Peoples R China
[3] Chinese Acad Med Sci, Peking Union Med Coll, Cardiovasc Inst, Beijing 100037, Peoples R China
[4] Univ Arizona, Tucson, AZ USA
来源
EUROPACE | 2011年 / 13卷 / 04期
关键词
Operator radiation exposure; Femoral vein; Steerable catheter; Fixed curve catheter; CARDIOLOGISTS;
D O I
10.1093/europace/euq515
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims To evaluate and compare operator radiation exposure during the catheter placement in the coronary sinus via the femoral vein with a steerable catheter or the jugular vein with a fixed curve catheter. Methods and results A total of 156 patients undergoing electrophysiological study or radiofrequency catheter ablation were prospectively assigned in a random fashion to either the femoral vein access (FVA) with a steerable curve deca-polar catheter (n = 80) or the jugular vein access (JVA) with a fixed curve deca-polar catheter (n 76). All the catheterization procedures were performed by the same operator who had extensive experience in both accesses. Operator radiation exposure was measured with an electronic radiation dosimeter attached to the breast pocket of the operator on the outside of the lead apron and estimates of the ambient dose equivalent were derived. The operator radiation exposure was reduced significantly by using the FVA compared with the JVA (1.8 +/- 1.3 vs. 8.6 +/- 6.5 mu Sv; P < 0.001). The fluoroscopy time (62.7 +/- 45.8 vs. 61.9 +/- 46.5 s; P = NS) and dose-area product (3.2 +/- 2.3 vs. 3.1 +/- 2.1 Gy cm(2); P = NS) were not statistically different. Conclusion Operator radiation exposure can be significantly reduced by using the FVA approach with a steerable curve catheter compared with the JVA approach with a fixed curve catheter, without increasing the fluoroscopy time and dose-area product.
引用
收藏
页码:539 / 542
页数:4
相关论文
共 8 条
[1]   Radiation Exposure of Patient and Physician during Implantation and Upgrade of Cardiac Resynchronization Devices [J].
Butter, Christian ;
Schau, Thomas ;
Meyhoefer, Juergen ;
Neumann, Klaus ;
Minden, Hans H. ;
Engelhardt, Joerg .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2010, 33 (08) :1003-1012
[2]  
Finkelstein MM, 1998, CAN J CARDIOL, V14, P1385
[3]   A TECHNIQUE FOR RAPID TRANSFEMORAL CATHETERIZATION OF THE CORONARY SINUS WITH MULTIELECTRODE CATHETERS [J].
KLEMAN, JM ;
PINSKI, SL ;
STERBA, R ;
KIDWELL, GA ;
TROHMAN, RG .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1994, 17 (11) :1737-1740
[4]   Significant reduction of radiation exposure to operator and staff during cardiac interventions by analysis of radiation leakage and improved lead shielding [J].
Kuon, E ;
Schmitt, M ;
Dahm, JB .
AMERICAN JOURNAL OF CARDIOLOGY, 2002, 89 (01) :44-49
[5]  
Mann JT, 1996, J INVASIVE CARDIOL, V8, pD22
[6]   X-ray dose and associated risks from radiofrequency catheter ablation procedures [J].
McFadden, SL ;
Mooney, RB ;
Shepherd, PH .
BRITISH JOURNAL OF RADIOLOGY, 2002, 75 (891) :253-265
[7]   Radiation exposure to cardiologists: how it could be reduced [J].
Vano, E .
HEART, 2003, 89 (10) :1123-1124
[8]  
von Boetticher Heiner, 2003, Z Med Phys, V13, P251