Technical and clinical evaluation of a closed loop TIVA system with SEDLineTM spectral density monitoring: Multicentric prospective cohort study

被引:16
作者
Castellanos Penaranda, Claudia [1 ,2 ]
Casas Arroyave, Fabian D. [3 ]
Gomez, Francisco J. [4 ]
Pinzon Corredor, Paola A. [5 ]
Fernandez, Juan M. [6 ]
Velez Botero, Marcela [2 ]
Bohorquez Bedoya, Juan D. [2 ]
Marulanda Toro, Carlos [7 ]
机构
[1] FUCS, Anesthesiol & Resuscitat, Bogota, Colombia
[2] Univ Antioquia, Fac Med, Anesthesiol & Resuscitat, Medellin, Colombia
[3] Univ Antioquia, Fac Med, Hosp Univ San Vicente Fdn, Medellin, Colombia
[4] Univ Antioquia, Fac Med, IPS Univ, Ambulatory Headquarters, Medellin, Colombia
[5] FUCS, Hosp San Jose, Bogota, Colombia
[6] Univ Antioquia, Fac Engn, Medellin, Colombia
[7] IPS Univ, Ambulatory Headquarters, Medellin, Colombia
关键词
Closed loop; Total intravenous anesthesia; Propofol; Remifentanil; SEDline; Spectral density; TARGET-CONTROLLED INFUSION; PATIENT STATE INDEX; BISPECTRAL INDEX; DRUG-DELIVERY; PROPOFOL; ANESTHESIA; RECOVERY;
D O I
10.1186/s13741-019-0130-2
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Introduction Closed loop total intravenous anesthesia is a technique in which the patient's hemodynamic and anesthetic depth variables are monitored, and based on this information, a computer controls the infusion rate of drugs to keep them within pre-established clinical parameters. Objective To describe the technical and clinical performance of a closed loop system for total intravenous anesthesia with propofol and remifentanil, using the SEDLine(TM) monitor Design Multicentric prospective cohort study Setting Surgery room Patients ASA I-II undergoing elective surgery Measurements The authors designed a closed loop system that implements a control algorithm based on anesthetic depth monitoring and the Patient State Index (PSITM) of the SEDLine monitor for propofol, and on hemodynamic variables for remifentanil. The measurement of clinical performance was made based on the percentage of PSITM maintenance time in the range 20-50. Precision analysis was evaluated by measuring median performance error (MDPE) can be defined as the median difference between actual and desired values, which refers to the degree of precision in which the controller is able to maintain the control variable within the objective set by the anesthesiologist; it represents the direction (over-prediction or under-prediction) of performance error (PE) rather than size of errors, which is represented by MDAPE, median absolute percentage error, Wobble index, which is used for measuring the intrasubject variability in performance error. Results Data were obtained from 93 patients in three healthcare centers. The percentage of PSITM maintenance time in the 20-50 range was 92% (80.7-97.0). MDPE was 10.7 (- 11.0-18.0), MDAPE 21.0 (14.2-26.8) and wobble 10.7 (7.0-16.9). No adverse surgical or anesthetic events were found. Conclusions The closed loop total intravenous anesthesia system with SEDLine developed by the authors was used without major complication and appear to be feasible its use in clinical performance.
引用
收藏
页数:11
相关论文
共 31 条
[1]   Pharmacokinetic models for propofol-defining and illuminating the devil in the detail [J].
Absalom, A. R. ;
Mani, V. ;
De Smet, T. ;
Struys, M. M. R. F. .
BRITISH JOURNAL OF ANAESTHESIA, 2009, 103 (01) :26-37
[2]  
Barvais L, 2013, ACTA ANAESTH BELG, V64, P137
[3]  
Casas F, 2015, SERIE CASOS PROSPECT
[4]   EVALUATION OF A CLOSED LOOP TOTAL INTRAVENOUS ANESTHESIA SYSTEM WITH BIS COMPARED TO AN OPEN LOOP TARGET CONTROLLED INFUSION SYSTEM (TCI): RANDOMIZED CONTROLLED CLINICAL TRIAL [J].
Casas, F. D. ;
Fernandez, J. M. .
ANESTHESIA AND ANALGESIA, 2016, 123 :766-767
[5]   A comparison of patient state index and bispectral index values during the perioperative period [J].
Chen, XG ;
Tang, J ;
White, PF ;
Wender, RH ;
Ma, H ;
Sloninsky, A ;
Kariger, R .
ANESTHESIA AND ANALGESIA, 2002, 95 (06) :1669-1674
[6]  
Corporation M, 2017, MON FUNC CER CON SED, P1
[7]   Guaranteeing drug delivery during total intravenous anaesthesia [J].
Craft, T. M. .
ANAESTHESIA, 2015, 70 (06) :758-759
[8]   The Pharmacology of Total Intravenous Anesthesia [J].
Darnobid, Jessica A. .
INTERNATIONAL ANESTHESIOLOGY CLINICS, 2015, 53 (02) :13-27
[9]   Patient state index [J].
Drover, David ;
Ortega, H. R. .
BEST PRACTICE & RESEARCH-CLINICAL ANAESTHESIOLOGY, 2006, 20 (01) :121-128
[10]   Patient state index - Titration of delivery and recovery from propofol, alfentanil, and nitrous oxide anesthesia [J].
Drover, DR ;
Lemmens, HJ ;
Pierce, ET ;
Plourde, G ;
Loyd, G ;
Ornstein, E ;
Prichep, LS ;
Chabot, RJ ;
Gugino, L .
ANESTHESIOLOGY, 2002, 97 (01) :82-89