Identification and quantification of selected plastics in biosolids by pressurized liquid extraction combined with double-shot pyrolysis gas chromatography-mass spectrometry

被引:180
作者
Okoffo, Elvis D. [1 ]
Ribeiro, Francisca [1 ,2 ]
O'Brien, Jake W. [1 ]
O'Brien, Stacey [1 ]
Tscharke, Benjamin J. [1 ]
Gallen, Michael [1 ]
Samanipour, Saer [3 ]
Mueller, Jochen F. [1 ]
Thomas, Kevin, V [1 ]
机构
[1] Univ Queensland, QAEHS, 20 Cornwall St, Woolloongabba, Qld 4102, Australia
[2] Univ Exeter, Coll Life & Environm Sci, Exeter EX4 4QD, Devon, England
[3] Norwegian Inst Water Res NIVA, N-0349 Oslo, Norway
关键词
Plastics; Pressurized liquid extraction; Double-shot Pyr-GC/MS; Quantification; Sewage sludge; Biosolids; WATER TREATMENT PLANTS; WASTE-WATER; ENVIRONMENTAL-SAMPLES; MICROPLASTIC POLLUTION; SEWAGE-SLUDGE; SEDIMENT; FIBERS; FATE; TRANSPORT; SURVIVAL;
D O I
10.1016/j.scitotenv.2020.136924
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The identification and quantification of selected plastics (polystyrene (PS), polycarbonate (PC), poly-(methyl methacrylate) (PMMA), polypropylene (PP), polyethylene terephthalate (PET), polyethylene (PE) and polyvinyl chloride (PVC)) in biosolids (treated sewage sludge) was performed by pressurized liquid extraction (PLE) combined with double-shot pyrolysis gas chromatography-mass spectrometry. Validation of the method yielded recoveries of between 85 and 128% (mean RSD 11%) at a linear range of between 0.01 and 2 mu g. The distribution of plastics within 25 biosolid samples from a single wastewater treatment plant in Australia was assessed. The mass concentration of PE, PVC, PP, PS and PMMA was between 0.1 and 4.1 mg/g dry weight (dw) across all with a total plastic concentration Sigma(Plastics) of between 2.8 and 6.6 mg/g dw (median = 4.1 mg/g dw). PE was the predominant plastic detected (mean concentration of 22 mg/g dw), contributing to 50% of the total of all plastics. Overall, this study demonstrates that pressurized liquid extraction (PLE) combined with double-shot pyrolysis gas chromatography-mass spectrometry can be used to identify and quantify PE, PP, PVC, PS, and PMMA in biosolids. (C) 2020 Elsevier B.V. All rights reserved.
引用
收藏
页数:9
相关论文
共 53 条
[1]   Atmospheric transport and deposition of microplastics in a remote mountain catchment [J].
Allen, Steve ;
Allen, Deonie ;
Phoenix, Vernon R. ;
Le Roux, Gael ;
Jimenez, Pilar Durantez ;
Simonneau, Anaelle ;
Binet, Stephane ;
Galop, Didier .
NATURE GEOSCIENCE, 2019, 12 (05) :339-+
[2]  
[Anonymous], AUSTR BIOS STAT
[3]   Studies of the effects of microplastics on aquatic organisms: What do we know and where should we focus our efforts in the future? [J].
de Sa, Luis Carlos ;
Oliveira, Miguel ;
Ribeiro, Francisca ;
Rocha, Thiago Lopes ;
Futter, Martyn Norman .
SCIENCE OF THE TOTAL ENVIRONMENT, 2018, 645 :1029-1039
[4]   Analytical pyrolysis as a tool to probe soil organic matter [J].
Derenne, Sylvie ;
Quenea, Katell .
JOURNAL OF ANALYTICAL AND APPLIED PYROLYSIS, 2015, 111 :108-120
[5]   Quantification of microplastics in environmental samples via pressurized liquid extraction and pyrolysis-gas chromatography [J].
Dierkes, Georg ;
Lauschke, Tim ;
Becher, Susanne ;
Schumacher, Heike ;
Foeldi, Corinna ;
Ternes, Thomas .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2019, 411 (26) :6959-6968
[6]   Fast identification of microplastics in complex environmental samples by a thermal degradation method [J].
Duemichen, Erik ;
Eisentraut, Paul ;
Bannick, Claus Gerhard ;
Barthel, Anne-Kathrin ;
Senz, Rainer ;
Braun, Ulrike .
CHEMOSPHERE, 2017, 174 :572-584
[7]   Two Birds with One Stone-Fast and Simultaneous Analysis of Microplastics: Microparticles Derived from Thermoplastics and Tire Wear [J].
Eisentraut, Paul ;
Duemichen, Erik ;
Ruhl, Aki Sebastian ;
Jekel, Martin ;
Albrecht, Mirko ;
Gehde, Michael ;
Braun, Ulrike .
ENVIRONMENTAL SCIENCE & TECHNOLOGY LETTERS, 2018, 5 (10) :608-613
[8]  
Fischer M, 2019, ANAL METHODS-UK, V11, P2489, DOI [10.1039/c9ay00600a, 10.1039/C9AY00600A]
[9]   Simultaneous Trace Identification and Quantification of Common Types of Microplastics in Environmental Samples by Pyrolysis-Gas Chromatography-Mass Spectrometry [J].
Fischer, Marten ;
Scholz-Boettcher, Barbara M. .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2017, 51 (09) :5052-5060
[10]   A Procedure for Measuring Microplastics using Pressurized Fluid Extraction [J].
Fuller, Stephen ;
Gautam, Anil .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2016, 50 (11) :5774-5780