Active millimeter-wave imaging for concealed weapons detection

被引:50
作者
Grossman, EN [1 ]
Miller, AJ [1 ]
机构
[1] Natl Inst Stand & Technol, Div Electromagnet Technol, Boulder, CO 80303 USA
来源
PASSIVE MILLIMETER-WAVE IMAGING TECHNOLOGY VI AND RADAR SENSOR TECHNOLOGY VII | 2003年 / 5077卷
关键词
bolometer; array; millimeter-wave; concealed weapons; imaging;
D O I
10.1117/12.488198
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Actively illuminated mm-wave imaging systems for concealed weapons detection offer the possibility of much higher sensitivity than with passive systems. We discuss several issues specific to mm-wave imaging systems that are actively illuminated and describe our implementation of such a system. We show that the illumination geometry is critical to the appearance and detectability of targets, and present measurements of the bi-directional reflectance distribution of a small handgun, as a prototypical target. We demonstrate suppression of standing waves using frequency modulated (FMCW) illumination and directly compare images taken with CW, FMCW, and pulsed illumination. Our implementation of an active imaging system is based on a 120-element focal-plane array (FPA) of uncooled antenna-coupled microbolometers. We describe the fabrication process and yield for these FPA's, as well as tests that show the performance of individual pixels on the 120-element array to be equivalent to that of isolated devices. These results demonstrate that wiring for readout of an antenna-coupled FPA can be made "transparent" to the antennas. Therefore, a mm-wave FPA that is read out through wiring to the perimeter of the array constitutes a simple and feasible architecture, in contrast to the infrared, where space limitations require vertical (3D) integration of readout and FPA. The electrical readout system for the FPA is also described. Finally, we present a result obtained with the full FPA system, showing that 3-way illumination is much more effective for detection of a complex target than a single directional illuminator.
引用
收藏
页码:62 / 70
页数:9
相关论文
共 8 条
  • [1] FOCAL-PLANE IMAGING-SYSTEMS FOR MILLIMETER WAVELENGTHS
    GOLDSMITH, PF
    HSIEH, CT
    HUGUENIN, GR
    KAPITZKY, J
    MOORE, EL
    [J]. IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1993, 41 (10) : 1664 - 1675
  • [2] Concealed weapons detection using an uncooled millimeter-wave microbolometer system
    Grossman, EN
    Bhupathiraju, AK
    Miller, AJ
    Reintsema, CD
    [J]. INFRARED AND PASSIVE MILLIMETER-WAVE IMAGING SYSTEMS: DESIGN, ANALYSIS, MODELING, AND TESTING, 2002, 4719 : 364 - 369
  • [3] Concealed weapons detection system using uncooled, pulsed, imaging arrays of millimeter-wave bolometers
    Grossman, EN
    Nolen, S
    Paulter, NG
    Reintsema, CD
    [J]. PASSIVE MILLIMETER-WAVE IMAGING TECHNOLOGY V, 2001, 4373 : 7 - 15
  • [4] Terahertz imaging system based on antenna-coupled microbolometers
    Luukanen, A
    Viitanen, VP
    [J]. PASSIVE MILLIMETER-WAVE IMAGING TECHNOLOGY II, 1998, 3378 : 34 - 44
  • [5] Properties of cavity-backed slot-ring antennas at 95 GHz
    Nolen, S
    Harvey, TE
    Reintsema, CD
    Grossman, EN
    [J]. PASSIVE MILLIMETER-WAVE IMAGING TECHNOLOGY V, 2001, 4373 : 49 - 57
  • [6] Antenna-coupled niobium bolometers for mm-wave imaging arrays
    Nolen, S
    Koch, J
    Paulter, N
    Reintsema, CD
    Grossman, EN
    [J]. TERAHERTZ AND GIGAHERTZ PHOTONICS, 1999, 3795 : 279 - 286
  • [7] Design of an active mm-wave concealed object imaging system
    Paulter, NG
    Grossman, EN
    Stenbakken, GN
    Waltrip, BC
    Nolen, S
    Reintsema, CD
    [J]. PASSIVE MILLIMETER-WAVE IMAGING TECHNOLOGY V, 2001, 4373 : 64 - 71
  • [8] Wood R. A., 1997, UNCOOLED INFRARED IM