Serotonin 1B receptor density mapping of the human brainstem using positron emission tomography and autoradiography

被引:3
作者
Veldman, Emma R. [1 ,2 ]
Varrone, Andrea [1 ,2 ]
Varnas, Katarina [1 ,2 ]
Svedberg, Marie M. [1 ,2 ,3 ]
Cselenyi, Zsolt [1 ,2 ,4 ]
Tiger, Mikael [1 ,2 ]
Gulyas, Balazs [1 ,2 ,5 ]
Halldin, Christer [1 ,2 ]
Lundberg, Johan [1 ,2 ]
机构
[1] Karolinska Inst, Ctr Psychiat Res, Dept Clin Neurosci, Stockholm, Sweden
[2] Stockholm Cty Council, Stockholm, Sweden
[3] Sophiahemmet Univ, Dept Hlth Promot Sci, Stockholm, Sweden
[4] AstraZeneca, R&D, PET Sci Ctr, Personalized Med & Biosamples, Stockholm, Sweden
[5] Nanyang Technol Univ, Lee Kong Chian Sch Med, Singapore, Singapore
基金
瑞典研究理事会;
关键词
Serotonin 1B (5-HT1B); positron emission tomography (PET); human; 3D autoradiography; brainstem; ANTERIOR CINGULATE CORTEX; TEST-RETEST RELIABILITY; 5-HT1B RECEPTOR; TRANSPORTER AVAILABILITY; HIGH-AFFINITY; PET; BINDING; QUANTIFICATION; RESOLUTION; SUBTYPES;
D O I
10.1177/0271678X211049185
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The serotonin 1B (5-HT1B) receptor has lately received considerable interest in relation to psychiatric and neurological diseases, partly due to findings based on quantification using Positron Emission Tomography (PET). Although the brainstem is an important structure in this regard, PET radioligand binding quantification in brainstem areas often shows poor reliability. This study aims to improve PET quantification of 5-HT1B receptor binding in the brainstem. Volumes of interest (VOIs) were selected based on a 3D [H-3]AZ10419369 Autoradiography brainstem model, which visualized 5-HT1B receptor distribution in high resolution. Two previously developed VOI delineation methods were tested and compared to a conventional manual method. For a method based on template data, a [C-11]AZ10419369 PET template was created by averaging parametric binding potential (BPND) images of 52 healthy subjects. VOIs were generated based on a predefined volume and BPND thresholding and subsequently applied to test-retest [C-11]AZ10419369 parametric BPND images of 8 healthy subjects. For a method based on individual subject data, VOIs were generated directly on each individual parametric image. Both methods showed improved reliability compared to a conventional manual VOI. The VOIs created with [C-11]AZ10419369 template data can be automatically applied to future PET studies measuring 5-HT1B receptor binding in the brainstem.
引用
收藏
页码:630 / 641
页数:12
相关论文
共 59 条
[1]  
Ahrens J., 2005, Paraview: An End-User Tool for Large Data Visualization, Visualization Handbook, DOI [DOI 10.1016/B978-012387582-2/50038-1, 10.1016/b978-012387582-2/50038-1]
[2]  
Anderson JW, 2007, CONTEMP MATH, V432, P1
[3]  
Arganda-Carreras I, 2006, LECT NOTES COMPUT SC, V4241, P85
[4]   CYTOARCHITECTURE OF THE HUMAN DORSAL RAPHE NUCLEUS [J].
BAKER, KG ;
HALLIDAY, GM ;
TORK, I .
JOURNAL OF COMPARATIVE NEUROLOGY, 1990, 301 (02) :147-161
[5]  
Be MM., 2010, Table of Radionuclides, V1-5
[6]   HEAD FIXATION DEVICE FOR REPRODUCIBLE POSITION ALIGNMENT IN TRANSMISSION CT AND POSITRON EMISSION TOMOGRAPHY [J].
BERGSTROM, M ;
BOETHIUS, J ;
ERIKSSON, L ;
GREITZ, T ;
RIBBE, T ;
WIDEN, L .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1981, 5 (01) :136-141
[7]  
Bonaventure P, 1997, RECEPTOR CHANNEL, V5, P225
[8]   TrakEM2 Software for Neural Circuit Reconstruction [J].
Cardona, Albert ;
Saalfeld, Stephan ;
Schindelin, Johannes ;
Arganda-Carreras, Ignacio ;
Preibisch, Stephan ;
Longair, Mark ;
Tomancak, Pavel ;
Hartenstein, Volker ;
Douglas, Rodney J. .
PLOS ONE, 2012, 7 (06)
[9]   The role of serotonin receptor subtypes in treating depression: a review of animal studies [J].
Carr, Gregory V. ;
Lucki, Irwin .
PSYCHOPHARMACOLOGY, 2011, 213 (2-3) :265-287
[10]   Differential distribution of [H-3]sumatriptan binding sites (5-HT1B, 5-HT1D and 5-HT1F receptors) in human brain: Focus on brainstem and spinal cord [J].
Castro, ME ;
Pascual, J ;
Romon, T ;
DelArco, C ;
DelOlmo, E ;
Pazos, A .
NEUROPHARMACOLOGY, 1997, 36 (4-5) :535-542