NEW METHOD OF COVERED WALLSTENTS FOR DISTAL MALIGNANT BILIARY OBSTRUCTION TO REDUCE EARLY STENT-RELATED COMPLICATIONS BASED ON CHARACTERISTICS

被引:29
作者
Nakai, Yousuke [1 ]
Isayama, Hiroyuki
Togawa, Osamu
Kogure, Hirofumi
Tsujino, Takeshi [3 ]
Yagioka, Hiroshi
Yashima, Yoko [4 ]
Sasaki, Takashi
Ito, Yukiko [3 ]
Matsubara, Saburo
Hirano, Kenji
Sasahira, Naoki
Toda, Nobuo [5 ]
Tada, Minoru
Kawabe, Takao [2 ]
Omata, Masao [2 ]
Koike, Kazuhiko
机构
[1] Univ Tokyo, Dept Gastroenterol, Grad Sch Med, Bunkyo Ku, Tokyo 1138655, Japan
[2] Univ Tokyo, Dept Endoscopy & Endoscop Surg, Tokyo 1138655, Japan
[3] Japanese Red Cross Med Ctr, Dept Gastroenterol, Tokyo, Japan
[4] JR Tokyo Gen Hosp, Dept Gastroenterol, Tokyo, Japan
[5] Mitsui Mem Hosp, Dept Gastroenterol, Tokyo 101, Japan
关键词
biliary tract neoplasms; cholestasis; extrahepatic; obstructive jaundice; stent; PAPILLARY BALLOON DILATION; COMMON BILE-DUCT; RANDOMIZED-TRIAL; METALLIC STENTS; MANAGEMENT; EFFICACY; SPHINCTEROTOMY; PALLIATION; JAUNDICE; PATENCY;
D O I
10.1111/j.1443-1661.2010.01043.x
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Aim: We previously reported a low occlusion rate with covered Wallstents for malignant biliary obstruction, but stent-related complications other than occlusion posed a problem. A modified covered Wallstent insertion method based on stent characteristics was evaluated to reduce stent-related complications. Methods: A total of 138 patients with distal malignant biliary obstruction received covered Wallstent placement. From October 2001 to October 2003, 69 patients received covered Wallstent placement (Group 1). Thereafter, we modified our stent insertion method and 69 patients received stent placement using this modified method from November 2003 to January 2007 (Group 2). The modified insertion method consists of endoscopic sphincterotomy carried out in patients without pancreatic duct invasion and longer stent placement with the center of the stent located in the center of the biliary stricture to prevent pancreatitis, kinking of the bile duct, and stent dislocation. A comparative analysis was carried out using prospectively collected data in these two cohorts. Results: Tumor ingrowth was not observed, and stent occlusion rate was 18.8% in Group 1 and 23.2% in Group 2. The overall rates of stent-related complications did not differ (39.1% in Group 1 and 30.4% in Group 2), but stent-related complications within 3 months decreased from 22 episodes in Group 1 to 13 episodes in Group 2. Median event-free survival was prolonged by modified stent insertion method (125 days in Group 1 and 268 days in Group 2, P = 0.020), although cumulative survival and stent patency were not significantly different. Conclusions: Our modified method of covered Wallstent placement showed improved event-free survival.
引用
收藏
页码:49 / 55
页数:7
相关论文
共 27 条
[1]   RANDOMIZED TRIAL OF ENDOSCOPIC ENDOPROSTHESIS VERSUS OPERATIVE BYPASS IN MALIGNANT OBSTRUCTIVE-JAUNDICE [J].
ANDERSEN, JR ;
SORENSEN, SM ;
KRUSE, A ;
ROKKJAER, M ;
MATZEN, P .
GUT, 1989, 30 (08) :1132-1135
[2]   Endoscopic sphincterotomy before deployment of covered metal stent is associated with greater complication rate - A prospective randomized control trial [J].
Artifon, Everson L. A. ;
Sakai, Paulo ;
Ishioka, Shinichi ;
Marques, Sergio B. ;
Lino, Andre S. ;
Cunha, Jose E. M. ;
Jukemura, Jose ;
Cecconello, Ivan ;
Carrilho, Flair J. ;
Opitz, Eduardo ;
Kumar, Atul .
JOURNAL OF CLINICAL GASTROENTEROLOGY, 2008, 42 (07) :815-819
[3]   RANDOMIZED TRIAL OF SELF-EXPANDING METAL STENTS VERSUS POLYETHYLENE STENTS FOR DISTAL MALIGNANT BILIARY OBSTRUCTION [J].
DAVIDS, PHP ;
GROEN, AK ;
RAUWS, EAJ ;
TYTGAT, GNJ ;
HUIBREGTSE, K .
LANCET, 1992, 340 (8834-5) :1488-1492
[4]   Impact of reducing duodenobiliary reflux on biliary stent patency: an in vitro evaluation and a prospective randomized clinical trial that used a biliary stent with an antireflux valve [J].
Dua, Kulwinder S. ;
Reddy, Nageshwar D. ;
Rao, Venkat G. ;
Banerjee, Rupa ;
Medda, Bidyut ;
Lang, Ivan .
GASTROINTESTINAL ENDOSCOPY, 2007, 65 (06) :819-828
[5]  
Hasebe O, 2004, DIGEST ENDOSC, V16, pS46
[6]   Polyurethane-covered metal stent for management of distal malignant biliary obstruction [J].
Isayama, H ;
Komatsu, Y ;
Tsujino, T ;
Yoshida, H ;
Tada, M ;
Shiratori, Y ;
Kawabe, T ;
Omata, M .
GASTROINTESTINAL ENDOSCOPY, 2002, 55 (03) :366-370
[7]   A prospective randomised study of "covered'' versus "uncovered'' diamond stents for the management of distal malignant biliary obstruction [J].
Isayama, H ;
Komatsu, Y ;
Tsujino, T ;
Sasahira, N ;
Hirano, K ;
Toda, N ;
Nakai, Y ;
Yamamoto, N ;
Tada, M ;
Yoshida, H ;
Shiratori, Y ;
Kawabe, T ;
Omata, M .
GUT, 2004, 53 (05) :729-734
[8]  
Isayama H, 2004, DIGEST ENDOSC, V16, pS104
[9]   Cholecystitis after metallic stent placement in patients with malignant distal biliary obstruction [J].
Isayama, Hiroyuki ;
Kawabe, Takao ;
Nakai, Yousuke ;
Tsujino, Takeshi ;
Sasahira, Naoki ;
Yamamoto, Natsuyo ;
Arizumi, Toshihiko ;
Togawa, Osamu ;
Matsubara, Saburou ;
Ito, Yukiko ;
Sasaki, Takashi ;
Hirano, Kenji ;
Toda, Nobuo ;
Komatsu, Yutaka ;
Tada, Minoru ;
Yoshida, Haruhiko ;
Omata, Masao .
CLINICAL GASTROENTEROLOGY AND HEPATOLOGY, 2006, 4 (09) :1148-1153
[10]   Measurement of radial and axial forces of biliary self-expandable metallic stents [J].
Isayama, Hiroyuki ;
Nakai, Yousuke ;
Toyokawa, Yoshihide ;
Togawa, Osamu ;
Gon, Chimyon ;
Ito, Yukiko ;
Yashima, Yoko ;
Yagioka, Hiroshi ;
Kogure, Hirofumi ;
Sasaki, Takashi ;
Arizumi, Toshihiko ;
Matsubara, Saburo ;
Yamamoto, Natsuyo ;
Sasahira, Naoki ;
Hirano, Kenji ;
Tsujino, Takeshi ;
Toda, Nobuo ;
Tada, Minoru ;
Kawabe, Takao ;
Omata, Masao .
GASTROINTESTINAL ENDOSCOPY, 2009, 70 (01) :37-44