The difference in chloride ion diffusion coefficient of concrete made with drinking water and wastewater

被引:46
作者
Hassani, Mohammad Sheikh [1 ]
Asadollahfardi, Gholamreza [2 ]
Saghravani, Seyed Fazlolah [1 ]
Jafari, Sahar [3 ]
Peighambarzadeh, Fahimeh Sadat [1 ]
机构
[1] Kharazmi Univ, Fac Engn, Civil Engn Dept, Tehran, Iran
[2] Shahrood Univ Technol, Fac Civil Engn, Civil Engn Dept, Shahrood, Iran
[3] Khajeh Nasir Toosi Univ Technol, Fac Civil Engn, Engn Dept, Tehran, Iran
关键词
Concrete samples; Non-potable water; Wastewater; Chloride ion diffusion coefficient; SEM images; SERVICE LIFE PREDICTION; COMBINED ATTACK; PENETRATION; RESISTANCE; CRACKS; MODEL;
D O I
10.1016/j.conbuildmat.2019.117182
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this study, the chloride ion penetration of concrete made with drinking water and domestic wastewater of the anaerobic pond (non-potable water) were evaluated through the experimental tests and finite difference method. We considered three mix designs with water to cement ratios between 0.4 and 0.6 for each category. We experimented the chloride ion percentage of the first eight layers of each concrete and then calculated their chloride diffusion coefficient by using the finite difference method (Implicit method). The results showed that the use of domestic wastewater increased the chloride ion percentage and chloride ion diffusion coefficient. Moreover, the homogeneous surfaces of concrete samples in using drinking water transformed into a new arrangement with more pores and voids, which can be a consequence of the presence of wastewater's impurities. Also, the high-resolution scanning electron microscopy (HRSEM) images and the field emission scanning electron microscopy (FESEM) images with energy dispersive X-ray (EDX) analysis of concrete surfaces before and after conducting the chloride ion test were provided to evaluate the morphological changes. Besides, a one-way analysis of variance (ANOVA) statistical test at the 5% significance level showed no significant difference between the chloride ion percentage of concrete in the experimental test and finite difference method. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页数:9
相关论文
共 37 条
  • [1] [Anonymous], 2012, APHA STAND METH EX W
  • [2] [Anonymous], C172316 ASTM INT
  • [3] [Anonymous], 2016, ANN BOOK ASTM STAND
  • [4] [Anonymous], 2009, 479 PNS BUILD HOUS R
  • [5] [Anonymous], 2017, C150C150M17 ASTM INT
  • [6] [Anonymous], 2018, Guidelines for Drinking Water Quality, DOI DOI 10.101651462-0758(00)00006-6
  • [7] [Anonymous], 2014, C136C136M14 ASTM INT
  • [8] [Anonymous], 2009, 1259 AASHTO
  • [9] [Anonymous], ASTM C114 2018
  • [10] ASTM C., 2018, 1602/C 1602M-18 Standard Specification for mixing Water Used in the Production of hydraulic Cement Concrete