High-Frequency Interdigitated Array Electrode-Based Capacitive Biosensor for Protein Detection

被引:21
作者
Tuan Vu Quoc [1 ,2 ]
Viet Nguyen Ngoc [2 ,3 ]
Tung Thanh Bui [3 ]
Jen, Chun-Ping [2 ]
Trinh Chu Duc [3 ]
机构
[1] Vietnam Acad Sci & Technol, Inst Appl Phys & Sci Instrument, Hanoi, Vietnam
[2] Natl Chung Cheng Univ, Dept Mech Engn, Chiayi, Taiwan
[3] Vietnam Natl Univ, Univ Engn & Technol, Hanoi, Vietnam
关键词
Capacitive immunosensor; Interdigitated array electrodes; Protein preconcentration; Protein detection; Impedance spectroscopy; BREAST-CANCER; IMPEDANCE; PRECONCENTRATION; ASSAYS;
D O I
10.1007/s13206-019-3412-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This paper reports a study on developing of a protein detection biochip based on interdigitated array electrodes (IDAEs) capacitive immunosensor. The protein after being preconcentrated in a detection region will be selectively captured and detected by the capacitive immunosensor. Using electrical impedance spectroscopy operated at high-frequency in the range of 100 kHz-1 MHz, the capacitance of the gold electrode is determined and the antibody surface modification steps can be also monitored. The experiment results show the capacitance changes in accordance with the adding biochemical layer on gold electrodes for each step of the antibody surface modification. In particular, the total impedance operated at 1 MHz frequency has been seen to change from 2.1 k omega of bare chip (before antibody surface modification) to 8 k omega after antibody surface modification process while the serial capacitance is recorded to reduce steadily from 450 pF to 55 pF. Also, the efficiency of protein chip was investigated by implementing the measurement of 10 mu M BSA with and without preconcentration process. The measurement results have shown the sensitivity increasing significantly after the protein is preconcentrated in this chip. The results demonstrate high efficiency of protein detection can be achieved by operating high frequency capacitive measurement on IDAEs capacitive immunosensor.
引用
收藏
页码:403 / 415
页数:13
相关论文
共 37 条
[1]   Integrated Microfluidic Devices Fabricated in Poly (Methyl Methacrylate) (PMMA) for On-site Therapeutic Drug Monitoring of Aminoglycosides in Whole Blood [J].
Al-aqbi, Zaidon T. ;
Yap, Yiing C. ;
Li, Feng ;
Breadmore, Michael C. .
BIOSENSORS-BASEL, 2019, 9 (01)
[2]   The application of protein microarray assays in psychoneuroimmunology [J].
Ayling, K. ;
Bowden, T. ;
Tighe, P. ;
Todd, I. ;
Dilnot, E. M. ;
Negm, O. H. ;
Fairclough, L. ;
Vedhara, K. .
BRAIN BEHAVIOR AND IMMUNITY, 2017, 59 :62-66
[3]   Characterization of coplanar electrode structures for microfluidic-based impedance spectroscopy [J].
Blume, Steffen O. P. ;
Ben-Mrad, Ridha ;
Sullivan, Pierre E. .
SENSORS AND ACTUATORS B-CHEMICAL, 2015, 218 :261-270
[4]   Challenges of Electrochemical Impedance Spectroscopy in Protein Biosensing [J].
Bogomolova, A. ;
Komarova, E. ;
Reber, K. ;
Gerasimov, T. ;
Yavuz, O. ;
Bhatt, S. ;
Aldissi, M. .
ANALYTICAL CHEMISTRY, 2009, 81 (10) :3944-3949
[5]   An AC electrokinetic impedance immunosensor for rapid detection of tuberculosis [J].
Cui, Haochen ;
Li, Shanshan ;
Yuan, Quan ;
Wadhwa, Ashutosh ;
Eda, Shigetoshi ;
Chambers, Mark ;
Ashford, Roland ;
Jiang, Hongyuan ;
Wu, Jie .
ANALYST, 2013, 138 (23) :7188-7196
[6]   Label-free impedance biosensors: Opportunities and challenges [J].
Daniels, Jonathan S. ;
Pourmand, Nader .
ELECTROANALYSIS, 2007, 19 (12) :1239-1257
[7]   AC frequency characteristics of coplanar impedance sensors as design parameters [J].
Hong, J ;
Yoon, DS ;
Kim, SK ;
Kim, TS ;
Kim, S ;
Pak, EY ;
No, K .
LAB ON A CHIP, 2005, 5 (03) :270-279
[8]  
Hudelist G, 2004, BREAST CANCER RES TR, V86, P281
[9]  
Ibrahim M., 2013, Journal of Electrical Bioimpedance, V4, P13, DOI DOI 10.5617/JEB.304
[10]   Analytical evaluation of the interdigital electrodes capacitance for a multi-layered structure [J].
Igreja, R ;
Dias, CJ .
SENSORS AND ACTUATORS A-PHYSICAL, 2004, 112 (2-3) :291-301