Evaluation of sampling techniques for detection and quantification of airborne legionellae at biological aeration basins and shower rooms

被引:24
作者
Chang, Ching-Wen [1 ,2 ,3 ]
Hung, Pei-Yu [1 ]
机构
[1] Natl Taiwan Univ, Coll Publ Hlth, Inst Environm Hlth, Taipei 100, Taiwan
[2] Natl Taiwan Univ, Ctr Res Environm & Occupat Hlth, Taipei 100, Taiwan
[3] Natl Taiwan Univ, Res Ctr Genes Environm & Human Hlth, Taipei 100, Taiwan
关键词
Legionella pneumophila; Bioaerosol; Biological aeration basin; Shower room; Real-time quantitative PCR; Ethidium monoazide; POLYMERASE-CHAIN-REACTION; REAL-TIME PCR; ETHIDIUM MONOAZIDE; QUANTITATIVE PCR; PROPIDIUM MONOAZIDE; PONTIAC FEVER; WATER SAMPLES; POLYMYXIN-B; PNEUMOPHILA; AEROSOLS;
D O I
10.1016/j.jaerosci.2012.02.003
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Inhalation of legionellae aerosolized from biological aeration basins (AB) and shower rooms (SR) has been linked to severe pneumonia and Pontiac fever. However, comprehensive evaluations at these facilities using various bioaerosol sampling techniques are lacking. This study assessed two agar-based (Andersen one-stage sampler and MAS-100/A), three liquid-based (BioSampler, AGI-30 and MAS-100/L) and two filter-based sampling methods (cassette/polycarbonate filter and 10M/gelatin filter) at AB. The BioSampler obtained the highest positive rate of culturable legionellae (8-50%) (P < 0.05). As for collecting total and viable legionellae, the IOM consistently showed the highest efficiencies regardless of sampling time (30-270 min). When assessing the cassette, BioSampler and AGI-30 at SR, the cassette was more efficient in collecting total and viable legionellae (P < 0.05), whereas only the BioSampler and AGI-30 recovered culturable legionellae. The viability percentages (calculated as viable cell counts to total cell counts, 12-77%) were not significantly different between the samplers regardless of sampling location and sampling time (P > 0.05). Overall, the IOM and cassette performed better for collecting total and viable legionellae, and culturable legionellae may be detected more frequently by the BioSampler at AB and SR. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:63 / 74
页数:12
相关论文
共 30 条
  • [11] Aerosolization of mycobacteria and legionellae during dental treatment:: low exposure despite dental unit contamination
    Dutil, Steve
    Veillette, Marc
    Meriaux, Anne
    Lazure, Louis
    Barbeau, Jean
    Duchaine, Caroline
    [J]. ENVIRONMENTAL MICROBIOLOGY, 2007, 9 (11) : 2836 - 2843
  • [12] THE DIFFERENTIAL ACTION OF CHEMICAL AGENTS, ESPECIALLY POLYMYXIN-B, ON CERTAIN ALGAE, BACTERIA AND FUNGI
    GALLOWAY, RA
    KRAUSS, RW
    [J]. AMERICAN JOURNAL OF BOTANY, 1959, 46 (01) : 40 - 49
  • [13] Investigation of inherent and latent internal losses in liquid-based bioaerosol samplers
    Han, Taewon
    Mainelis, Gediminas
    [J]. JOURNAL OF AEROSOL SCIENCE, 2012, 45 : 58 - 68
  • [14] Sampling and detection of Legionella pneumophila aerosols generated from an industrial cooling tower
    Ishimatsu, S
    Miyamoto, H
    Hori, H
    Tanaka, I
    Yoshida, S
    [J]. ANNALS OF OCCUPATIONAL HYGIENE, 2001, 45 (06) : 421 - 427
  • [15] Ultraviolet germicidal irradiation and titanium dioxide photocatalyst for controlling Legionella pneumophila
    Li, CS
    Tseng, CC
    Lai, HH
    Chang, CW
    [J]. AEROSOL SCIENCE AND TECHNOLOGY, 2003, 37 (12) : 961 - 966
  • [16] Survival of airborne microorganisms during swirling aerosol collection
    Lin, XJ
    Reponen, T
    Willeke, K
    Wang, Z
    Grinshpun, SA
    Trunov, M
    [J]. AEROSOL SCIENCE AND TECHNOLOGY, 2000, 32 (03) : 184 - 196
  • [17] EFFICIENCY AND LOADING CHARACTERISTICS OF EPAS HIGH-TEMPERATURE QUARTZ FIBER FILTER MEDIA
    LUNDGREN, DA
    GUNDERSON, TC
    [J]. AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1975, 36 (12): : 866 - 872
  • [18] Macher JM, 2001, AIR SAMPLING INSTRUM, P661
  • [19] USE OF POLYMERASE CHAIN-REACTION IN AN EPIDEMIOLOGIC INVESTIGATION OF PONTIAC FEVER
    MILLER, LA
    BEEBE, JL
    BUTLER, JC
    MARTIN, W
    BENSON, R
    HOFFMAN, RE
    FIELDS, BS
    [J]. JOURNAL OF INFECTIOUS DISEASES, 1993, 168 (03) : 769 - 772
  • [20] Real-time PCR assay for the detection and quantification of Legionella pneumophila in environmental water samples:: Utility for daily practice
    Morio, Florent
    Corvec, Stephane
    Caroff, Nathalie
    Le Gallou, Florence
    Drugeon, Henri
    Reynaud, Alain
    [J]. INTERNATIONAL JOURNAL OF HYGIENE AND ENVIRONMENTAL HEALTH, 2008, 211 (3-4) : 403 - 411