A new cleanup method of dioxins in sediment using large volume injection gas chromatography online coupled with liquid chromatography

被引:4
作者
Tang, Fengmei [1 ,2 ]
Ni, Yuwen [1 ]
Zhang, Haijun [1 ]
Li, Yun [1 ]
Jin, Jing [1 ]
Wang, Longxing [1 ]
Chen, Jiping [1 ]
机构
[1] Chinese Acad Sci, Dalian Inst Chem Phys, Dalian 116023, Peoples R China
[2] Chinese Acad Sci, Grad Sch, Beijing 100049, Peoples R China
基金
中国国家自然科学基金; 国家高技术研究发展计划(863计划);
关键词
Dioxins; Online cleanup; Gas chromatography; Liquid chromatography; Large volume injection; DIBENZO-P-DIOXINS; MAGNETIC-RESONANCE-SPECTROSCOPY; SOLVENT VAPOR EXIT; POLYCHLORINATED DIBENZOFURANS; ENVIRONMENTAL-SAMPLES; MASS SPECTROMETRY; PERFORMANCE; COLUMNS; SYSTEM; PCBS;
D O I
10.1016/j.aca.2012.04.004
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new cleanup method was developed and validated for the determination of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) in sediment. The sample extract was first treated with sulfuric acid and then cleaned up by a large volume injection gas chromatography online coupled with liquid chromatography (LVI-GC-LC) system. PCDD/Fs in the extract were separated by a GC column (DB-5), selected cut, cool trapped and transferred to a LC column (alumina). The fraction of PCDD/Fs eluted from the alumina column was collected and concentrated for the instrumental analysis. Under the optimized conditions, LVI-GC-LC method achieved the recoveries of 57-102% for 2,3,7,8-substituted PCDD/Fs, which met the requirements of US Environmental Protection Agency (EPA) Method 1613 and were better than those obtained using the conventional multistep column cleanup method. Meanwhile, compared with the conventional method, the limit of detection (LOD) values of 2,3,7,8-substituted PCDD/Fs cleaned up by LVI-GC-LC method were decreased due to the high-efficiency removal of interferents. These results suggested that the LVI-GC-LC cleanup method was a promising alternative to the multistep cleanup procedure for the determination of dioxins in environmental samples. Crown Copyright (C) 2012 Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:73 / 79
页数:7
相关论文
共 33 条
[1]   Evaluation of a new automated cleanup system for the analysis of polychlorinated dibenzo-p-dioxins and dibenzofurans in environmental samples [J].
Abad, E ;
Sauló, J ;
Caixach, J ;
Rivera, J .
JOURNAL OF CHROMATOGRAPHY A, 2000, 893 (02) :383-391
[2]  
Boselli E, 1999, HRC-J HIGH RES CHROM, V22, P149
[3]   A study of large-volume on-column injection GC-ECD for the ultratrace analysis of organochlorine pesticides in water [J].
Concha-Grana, E. ;
Fernandez-Martinez, G. ;
Fernandez-Villarrenaga, V. ;
Turnes-Carou, M. I. ;
Muniategui-Lorenzo, S. ;
Lopez-Mahia, P. ;
Prada-Rodriguez, D. .
TALANTA, 2009, 78 (03) :764-771
[4]   Determination of brominated flame retardants, with emphasis on polybrominated diphenyl ethers (PBDEs) in environmental and human samples - a review [J].
Covaci, A ;
Voorspoels, S ;
de Boer, J .
ENVIRONMENT INTERNATIONAL, 2003, 29 (06) :735-756
[5]   THE RELATIVE CONTRIBUTION OF INDIVIDUAL POLYCHLORINATED-BIPHENYLS (PCBS), POLYCHLORINATED DIBENZO-P-DIOXINS (PCDDS) AND POLYCHLORINATED DIBENZO-P-FURANS (PCDFS) TO TOXIC EQUIVALENT VALUES DERIVED FOR BULKED HUMAN ADIPOSE-TISSUE SAMPLES FROM WALES, UNITED-KINGDOM [J].
DUARTEDAVIDSON, R ;
HARRAD, SJ ;
ALLEN, S ;
SEWART, AS ;
JONES, KC .
ARCHIVES OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, 1993, 24 (01) :100-107
[6]   DEVELOPMENT AND PERFORMANCE OF A SEMIAUTOMATED CLEANUP PROCEDURE FOR THE ANALYSIS OF PCDD/PCDF IN GROUND WHOLE FISH SAMPLES [J].
EITZER, BD ;
HUANG, LQ ;
PAIVA, AA .
CHEMOSPHERE, 1992, 25 (7-10) :1305-1309
[7]   Method for small-molecule discovery based on microscale-preparative multidimensional gas chromatography isolation with nuclear magnetic resonance spectroscopy [J].
Eyres, Graham T. ;
Urban, Sylvia ;
Morrison, Paul D. ;
Dufour, Jean-Pierre ;
Marriott, Philip J. .
ANALYTICAL CHEMISTRY, 2008, 80 (16) :6293-6299
[8]   Application of microscale-preparative multidimensional gas chromatography with nuclear magnetic resonance spectroscopy for identification of pure methylnaphthalenes from crude oils [J].
Eyres, Graham T. ;
Urban, Sylvia ;
Morrison, Paul D. ;
Marriott, Philip J. .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1215 (1-2) :168-176
[9]   Automated sample preparation-fractionation for the measurement of dioxins and related compounds in biological matrices: a review [J].
Focant, JF ;
Pirard, C ;
De Pauw, E .
TALANTA, 2004, 63 (05) :1101-1113
[10]   LOOP-TYPE INTERFACE FOR CONCURRENT SOLVENT EVAPORATION IN COUPLED HPLC-GC - ANALYSIS OF RASPBERRY KETONE IN A RASPBERRY SAUCE AS AN EXAMPLE [J].
GROB, K ;
STOLL, JM .
JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1986, 9 (09) :518-523