An efficient treatment planning approach to reduce the critical organ dose in volumetric modulated arc therapy for synchronous bilateral breast cancer patients

被引:3
|
作者
Lin, Y. F. [1 ]
Shueng, P. W. [1 ,2 ]
Lin, H. H. [3 ,4 ,5 ]
Tien, H. J. [1 ]
Lai, L. H. [6 ]
机构
[1] Far Eastern Mem Hosp, Dept Radiat Oncol, New Taipei, Taiwan
[2] Natl Yang Ming Univ, Sch Med, Dept Med, Taipei, Taiwan
[3] Chang Gung Univ, Inst Radiol Res, Med Phys Res Ctr, Chang Gung Mem Hosp, Taoyuan, Taiwan
[4] Chang Gung Mem Hosp, Dept Radiat Oncol, Taoyuan, Taiwan
[5] Chang Gung Univ, Inst Radiol Res, Particle Phys & Beam Delivery Core Lab, Chang Gung Mem Hosp, Taoyuan, Taiwan
[6] China Med Univ, Dept Biomed Imaging & Radiol Sci, 91 Hsueh Shih Rd, Taichung 40402, Taiwan
关键词
Synchronous bilateral breast cancer; Volumetric modulated arc therapy; Partial arc; Pseudo planning structure; RADIOTHERAPY; RADIATION; RISK; OPTIMIZATION; IRRADIATION; DISEASE;
D O I
10.1016/j.radphyschem.2020.108957
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Treatment planning for patients with synchronous bilateral breast cancer (SBBC) is challenging due to the technical complexity of bilateral treatment. To minimize both high-dose and low-dose volumes of the heart and lungs being irradiated, we proposed an efficient and simple strategy for volumetric modulated arc therapy (VMAT) treatment planning in this study. Five SBBC patients were enrolled in this study. We utilized two pseudo block planning structures to minimize the high-dose volume of the whole lungs and heart and confine the low-dose areas in normal organs for VMAT planning. The prescription delivered was 45 Gy in 25 fractions to the whole breast. The VMAT treatment plan consisted of two partial arcs. In terms of the whole lungs, the average V-5Gy, V-10Gy and V-20Gy in the VMAT-B plan (with two pseudo planning block structures) for the five patients were 34.8 +/- 7.2%, 23.4 +/- 5.0% and 14.8 +/- 3.0%, respectively. For the VMAT-NB plan (without two pseudo planning block structures), the average V-5Gy, V-10Gy and V-20Gy were 38.6 +/- 6.8%, 27 +/- 5.9% and 18.4 +/- 4.0%, respectively. For the heart, the average V-5Gy, V-10Gy, V-20Gy and V-30Gy in the VMAT-B plan were 19.6 +/- 3.1%, 7.0 +/- 2.5%, 2.2 +/- 1.2% and 0.7 +/- 0.7%, respectively, while the mean values in the VMAT-NB plan were 26.2 +/- 6.3%, 11.3 +/- 3.9%, 3.9 +/- 1.8% and 1.5 +/- 1.1%, respectively. We designed an approach to reduce both the high-dose and low-dose volumes by utilizing pseudo planning structures in the VMAT treatment plan. The dosimetric results of this study showed that the pseudo block structures have the potential to reduce the risks of radiation pneumonitis and heart disease, while preserving the same tumor control rate.
引用
收藏
页数:5
相关论文
共 50 条
  • [31] Tangent-based volumetric modulated arc therapy for advanced left breast cancer
    Yu, Pei-Chieh
    Wu, Ching-Jung
    Nien, Hsin-Hua
    Lui, Louis Tak
    Shaw, Suzun
    Tsai, Yu-Lun
    RADIATION ONCOLOGY, 2018, 13
  • [32] Tangential Volumetric Modulated Arc Therapy for Locally Advanced Breast Cancer
    Zamora, Pedro L.
    Baran, Geoffrey
    Nagle, Christopher
    Hammoud, Ahmad
    Dominello, Michael
    PRACTICAL RADIATION ONCOLOGY, 2022, 12 (04) : E339 - E343
  • [33] Volumetric modulated arc therapy (VMAT) in the treatment of esophageal cancer patients
    Stefania Martini
    Francesca Arcadipane
    Paolo Strignano
    Rosella Spadi
    Viviana Contu
    Christian Fiandra
    Riccardo Ragona
    Giorgia Catalano
    Maria Antonietta Satolli
    Michele Camandona
    Renato Romagnoli
    Umberto Ricardi
    Pierfrancesco Franco
    Medical Oncology, 2018, 35
  • [34] Safety and outcomes of volumetric modulated arc therapy in the treatment of patients with inoperable lung cancer
    Jin, Xiance
    Lin, Baochai
    Chen, Didi
    Li, Lili
    Han, Ce
    Zhou, Yongqiang
    Zheng, Xiaomin
    Gong, Changfei
    Chen, Mengfeng
    Xie, Congying
    JOURNAL OF CANCER, 2019, 10 (13): : 2868 - 2873
  • [35] Dosimetric Effect on Breast Cancer Patients Treated with Volumetric-Modulated Arc Therapy: Single Institutional Experience
    Hashem, Rania
    Mulla, Zaheeda
    Ghassal, Nour
    Bokhary, Ayman
    Howladar, Fatimah
    Fallatah, Kholoud
    Iskandarani, Omar
    Attar, Mohammad
    Ujaimi, Reem
    INTERNATIONAL JOURNAL OF MEDICAL RESEARCH & HEALTH SCIENCES, 2021, 10 (02): : 55 - 62
  • [36] A dosimetric study of volumetric modulated arc therapy planning techniques for treatment of low-risk prostate cancer in patients with bilateral hip prostheses
    Rana, Suresh B.
    Pokharel, Shyam
    SOUTH ASIAN JOURNAL OF CANCER, 2014, 3 (01) : 18 - 21
  • [37] A robust planning approach for respiratory motion in accelerated partial breast irradiation using volumetric modulated arc therapy
    Yamauchi, Ryohei
    Tomita, Fumihiro
    Ishikura, Satoshi
    JOURNAL OF RADIATION RESEARCH, 2025, : 185 - 195
  • [38] Dosimetric comparison between volumetric modulated arc therapy planning techniques for prostate cancer in the presence of intrafractional organ deformation
    Varnava, Maria
    Sumida, Iori
    Oda, Michio
    Kurosu, Keita
    Isohashi, Fumiaki
    Seo, Yuji
    Otani, Keisuke
    Ogawa, Kazuhiko
    JOURNAL OF RADIATION RESEARCH, 2021, 62 (02) : 309 - 318
  • [39] Dose-volume Histogram Analysis of Knowledge-based Volumetric-modulated Arc Therapy Planning in Postoperative Breast Cancer Irradiation
    Inoue, Eri
    Doi, Hiroshi
    Monzen, Hajime
    Tamura, Mikoto
    Inada, Masahiro
    Ishikawa, Kazuki
    Nakamatsu, Kiyoshi
    Nishimura, Yasumasa
    IN VIVO, 2020, 34 (03): : 1095 - 1101
  • [40] Adaptive approach for nasopharyngeal carcinoma patients during Volumetric Modulated Arc Therapy treatment (VMAT)
    Chibane, B., I
    Benrachi, F.
    Bali, M. Salah
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2020, 18 (02): : 369 - 374