Fluorescent photoinduced electron transfer (PET) sensors for anions; From design to potential application

被引:199
|
作者
Gunnlaugsson, T [1 ]
Ali, HDP
Glynn, M
Kruger, PE
Hussey, GM
Pfeffer, FM
dos Santos, CMG
Tierney, J
机构
[1] Univ Dublin Trinity Coll, Dept Chem, Ctr Synth & Chem Biol, Dublin 2, Ireland
[2] Deakin Univ, Sch Biol & Chem Sci, Waurn Ponds 3217, Australia
基金
英国惠康基金;
关键词
anions; sensing; chemosensors; PET; fluorescence; acetate; phosphate; halides; fluoride;
D O I
10.1007/s10895-005-2627-y
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This mini review highlights the synthesis and photophysical evaluation of anion sensors, for nonaqueous solutions, that have been developed in our laboratories over the last few years. We have focused our research mainly on developing fluorescent photoinduced electron transfer (PET) sensors based on the fluorophore-spacer-anion receptor principle using several anthracene (emitting in the blue) and 1,8-naphthalimide (emitting in the green) fluorophores, with the aim of targeting biologically and industrially relevant anions such as acetates, phosphate and amino acids, as well as halides such as fluoride. The receptors and the fluorophore are separated by a short methyl or ethyl spacer, where the charge neutral anion receptors are either aliphatic or aromatic urea (or thiourea) moieties. For these, the anion recognition is through hydrogen bonding, yielding anion:receptor complexes. Such bonding gives rise to enhanced reduction potential in the receptor moieties which causes enhancement in the rate of PET quenching of the fluorophore excited state from the anion:receptor moiety. This design can be further elaborated on by incorporating either two fluorophores, or urea/thiourea receptors into the sensor structures, using anthracene as a fluorophore. For the latter design, the sensors were designed to achieve sensing of bis-anions, such as di-carboxylates or pyrophosphate, where the anion bridged the anthracene moiety. In the case of the naphthalimide based mono-receptor based PET sensors, it was discovered that in DMSO the sensors were also susceptible to deprotonation by anions such as F- at high concentrations. This led to substantial changes in the absorption spectra of these sensors, where the solution changed colour from yellow/green to deep blue, which was clearly visible to the naked eye. Hence, some of the examples presented can act as dual fluorescent-colorimetric sensors for anions. Further investigations into this phenomenon led to the development of simple colorimetric sensors for fluorides, which upon exposure to air, were shown to fix carbon dioxide as bicarbonate.
引用
收藏
页码:287 / 299
页数:13
相关论文
共 50 条
  • [1] Fluorescent Photoinduced Electron Transfer (PET) Sensors for Anions; From Design to Potential Application
    Thorfinnur Gunnlaugsson
    Haslin Dato Paduka Ali
    Mark Glynn
    Paul E. Kruger
    Gillian M. Hussey
    Frederick M. Pfeffer
    Cidália M. G. dos Santos
    Juliann Tierney
    Journal of Fluorescence, 2005, 15 : 287 - 299
  • [2] FLUORESCENT PET (PHOTOINDUCED ELECTRON-TRANSFER) SENSORS
    BISSELL, RA
    DE SILVA, AP
    GUNARATNE, HQN
    LYNCH, PLM
    MAGUIRE, GEM
    MCCOY, CP
    SANDANAYAKE, KRAS
    PHOTOINDUCED ELECTRON TRANSFER V, 1993, 168 : 223 - 264
  • [3] Fluorescent PET (Photoinduced Electron Transfer) sensors as potent analytical tools
    de Silva, A. Prasanna
    Moody, Thomas S.
    Wright, Glenn D.
    ANALYST, 2009, 134 (12) : 2385 - 2393
  • [4] Current developments in fluorescent PET (photoinduced electron transfer) sensors and switches
    Daly, Brian
    Ling, Jue
    de Silva, A. Prasanna
    CHEMICAL SOCIETY REVIEWS, 2015, 44 (13) : 4203 - 4211
  • [5] Fluorescent photoinduced electron transfer (PET) cation sensors derived from natural products.
    de Silva, S
    Loo, K
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2005, 229 : U379 - U379
  • [6] Fluorescent photoinduced electron transfer (PET) sensing of anions using charge neutral chemosensors
    Gunnlaugsson, T
    Davis, AP
    Glynn, M
    CHEMICAL COMMUNICATIONS, 2001, (24) : 2556 - 2557
  • [7] Rational design of fluorescent viscosity sensors by the principle of photoinduced electron transfer
    Wu, Zhiyong
    Cui, Jingnan
    Qian, Xuhong
    TETRAHEDRON LETTERS, 2013, 54 (21) : 2575 - 2578
  • [8] Structural and computational studies of fluorescent photoinduced electron transfer (PET) sensors for cations.
    de Silva, SA
    Whitener, MA
    Kasner, ML
    Pathirana, SL
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2003, 226 : U251 - U252
  • [9] FLUORESCENT PET (PHOTOINDUCED ELECTRON-TRANSFER) SENSORS - THE SIMPLE LOGIC AND ITS EXTENSIONS
    DESILVA, AP
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1992, 204 : 203 - ORGN
  • [10] Design of biomolecular sensors based on photoinduced electron transfer (PET) and molecular recognition
    Dyer, DJ
    Xu, RS
    Puli, S
    Cook, C
    McCarroll, ME
    Kimaru, I
    Shi, Y
    Wang, LH
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2005, 230 : U3012 - U3013