A viscous film sample chamber for Laser Ablation Inductively Coupled Plasma - Mass Spectrometry

被引:6
作者
Monticelli, Damiano [1 ]
Civati, Davide [1 ]
Giussani, Barbara [1 ]
Dossi, Carlo [1 ]
Spanu, Davide [1 ]
Recchia, Sandro [1 ]
机构
[1] Univ Insubria, Dipartimento Sci & Alta Tecnol, Via Valleggio 11, I-22100 Como, Italy
关键词
Laser ablation; Inductively Coupled Plasma Mass; Spectrometry; Ablation cell; Washout time; LA-ICP-MS; HIGH-SPEED; CELL; TRANSPORT; ENTRAINMENT; EFFICIENCY; RESOLUTION; ELEMENTS; SYSTEM; TORCH;
D O I
10.1016/j.talanta.2017.10.060
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Laser Ablation - Inductively Coupled Plasma - Mass Spectrometry (LA-ICP-MS) is a powerful method to determine the elemental composition of solid-state samples as it combines the high sensitivity and isotope selectivity of ICP-MS detection and the simplicity of laser ablation sampling. This technique enables rapid multiple sampling of the analysed material, such as needed for mapping or in-depth profiling applications. However, the duration of these measurements is practically restricted by the time taken for the particle to be transported from the sampling point to the ICP torch. The ablation cell, i.e. the sample holder, should combine high removal rate, high efficiency (i.e. complete transport of the ablated material) and reduced memory effects. These goals may be achieved by carefully designing the geometry of the cell and its gas flow patterns. A new cell design which enables a homogeneous wahout time of around 210 ms from a cylindrical chamber with 70 mm diameter is introduced in this paper. Washout time was determined as the time for the transient signal of 238U from a NIST610 glass standard to fall to 10% of its peak value. This result is achieved by combining a diffused, cylindrical flow pattern with an extraction tube coaxial with the laser beam and fixed to the laser assembly which enables the sampling point to be constantly positioned on the ablation spot. The lower part of the cell is mounted on the x,y stage for sample movement: the cell sealing is warranted by a viscous film junction between the lower and upper cell parts. Optimisation and performances of the apparatus are discussed in detail and performances are compared to existing designs.
引用
收藏
页码:100 / 106
页数:7
相关论文
共 50 条
[21]   Analysis of α-alumina samples by mass spectrometry with inductively coupled plasma and laser ablation [J].
V. A. Khvostikov ;
V. K. Karandashev ;
Zh. P. Burmii .
Inorganic Materials, 2015, 51 :1410-1415
[22]   Determination of Chromium Based on Laser Ablation Inductively Coupled Plasma Mass Spectrometry [J].
Wei, Xing ;
Zhou, Jing-Jing ;
Liu, Jin-Hui ;
Chen, Ming-Li ;
Wang, Jian-Hua .
CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2021, 49 (03) :432-439
[23]   APPLICATION OF LASER ABLATION INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY FOR SOIL ANALYSIS: A NOVEL PROCEDURE FOR SAMPLE PREPARATION [J].
Lyubomirova, Valentina ;
Todorov, Boyan ;
Djingova, Rumyana .
COMPTES RENDUS DE L ACADEMIE BULGARE DES SCIENCES, 2016, 69 (03) :275-282
[24]   On-line isotope dilution in laser ablation inductively coupled plasma mass spectrometry using a microflow nebulizer inserted in the laser ablation chamber [J].
Pickhardt, C ;
Izmer, AV ;
Zoriy, MV ;
Schaumlöffel, D ;
Becker, JS .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2006, 248 (03) :136-141
[25]   Application of μ-TLC for speciation of inorganic arsenic by laser ablation inductively coupled plasma mass spectrometry [J].
Kisomi, Amir Shafiee ;
Alizadeh, Taher ;
Shakeri, Alireza ;
Nouri, Arezoo ;
Farsadrooh, Majid ;
AsliPashaki, Shabnam Najafi .
MICROCHEMICAL JOURNAL, 2020, 159
[26]   Current Status and Prospects of Coupling Laser Ablation with Inductively Coupled Plasma Mass Spectrometry in Geochemistry [J].
Jarosova, Monika ;
Sulovsky, Petr ;
Milde, David .
CHEMICKE LISTY, 2016, 110 (11) :769-778
[27]   A "wire" signal smoothing device for laser ablation inductively coupled plasma mass spectrometry analysis [J].
Hu, Zhaochu ;
Liu, Yongsheng ;
Gao, Shan ;
Xiao, Shaoquan ;
Zhao, Laishi ;
Guenther, Detlef ;
Li, Ming ;
Zhang, Wen ;
Zong, Keqing .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2012, 78 :50-57
[28]   Elemental Bioimaging by Means of Fast Scanning Laser Ablation-Inductively Coupled Plasma-Mass Spectrometry [J].
Wehe, Christoph A. ;
Thyssen, Georgina M. ;
Herdering, Christina ;
Raj, Indra ;
Ciarimboli, Giuliano ;
Sperling, Michael ;
Karst, Uwe .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2015, 26 (08) :1274-1282
[29]   The effects of He on ablation and inductively coupled plasma environment in ultra-violet, nanosecond laser ablation inductively coupled plasma mass spectrometry [J].
Moses, Lance M. ;
Farnsworth, Paul B. .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2015, 113 :138-146
[30]   Lead determination in whole blood by laser ablation coupled with inductively coupled plasma mass spectrometry [J].
Hsieh, Hui-Fang ;
Chang, Wei-Shan ;
Hsieh, Yi-Kong ;
Wang, Chu-Fang .
TALANTA, 2009, 79 (02) :183-188