The effect of device-based cardiac contractility modulation therapy on myocardial efficiency and oxidative metabolism in patients with heart failure

被引:21
|
作者
Goliasch, Georg [1 ]
Khorsand, Aliasghar [1 ]
Schuetz, Matthias [2 ]
Karanikas, Georgios [2 ]
Khazen, Cesar [3 ]
Sochor, Heinz [1 ]
Schmidinger, Herwig [1 ]
Wolzt, Michael [1 ,4 ]
Graf, Senta [1 ]
机构
[1] Med Univ Vienna, Vienna Gen Hosp, Dept Cardiol, A-1090 Vienna, Austria
[2] Med Univ Vienna, Vienna Gen Hosp, Dept Nucl Med, A-1090 Vienna, Austria
[3] Med Univ Vienna, Vienna Gen Hosp, Dept Cardiothorac Surg, A-1090 Vienna, Austria
[4] Med Univ Vienna, Vienna Gen Hosp, Dept Clin Pharmacol, A-1090 Vienna, Austria
关键词
Cardiac contractility modulation; PET; Device therapy; Heart failure; POSITRON-EMISSION-TOMOGRAPHY; ABSOLUTE REFRACTORY PERIOD; ELECTRICAL SIGNALS; OXYGEN-CONSUMPTION; DOUBLE-BLIND; RESYNCHRONIZATION;
D O I
10.1007/s00259-011-1977-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Cardiac contractility modulation (CCM) is a device-based therapy that involves delivery of nonexcitatory electrical signals resulting in improved ventricular function and a reversal of maladaptive cardiac fetal gene programmes. Our aim was to evaluate whether acute application of CCM leads to an increase in myocardial oxygen consumption (MVO2) in patients with chronic heart failure using C-11-acetate positron emission tomography (PET). Methods We prospectively enrolled 21 patients with severe heart failure. C-11-acetate PET was performed before and after activation of the CCM device. In 12 patients an additional stress study with dobutamine was performed. Results Under resting conditions, the values of myocardial blood flow (MBF), MVO2 and work metabolic index (WMI, reflecting myocardial efficiency) with the CCM device activated did not differ significantly from the values with the device deactivated. MBF was 0.81 +/- 0.18 ml min(-1) g(-1) with the device off and 0.80 +/- 0.15 ml min(-1) g(-1) with the device on (p=0.818), MVO2 was 6.81 +/- 1.69 ml/min/100 g with the device off and 7.15 +/- 1.62 ml/min/100 g with the device on (p=0.241) and WMI was 4.94 +/- 1.14 mmHg ml/m(2) with the device off and 5.21 +/- 1.36 mmHg ml/m(2) with the device on (p=0.344). Under dobutamine stress, the values of MBF, MVO2 and WMI with the CCM device activated did not differ from the values with the device deactivated, but were significantly increased compared with the values obtained under resting conditions. Conclusion These results indicate that CCM does not induce increased MVO2, even under stress conditions.
引用
收藏
页码:408 / 415
页数:8
相关论文
共 50 条
  • [1] The effect of device-based cardiac contractility modulation therapy on myocardial efficiency and oxidative metabolism in patients with heart failure
    Georg Goliasch
    Aliasghar Khorsand
    Matthias Schütz
    Georgios Karanikas
    Cesar Khazen
    Heinz Sochor
    Herwig Schmidinger
    Michael Wolzt
    Senta Graf
    European Journal of Nuclear Medicine and Molecular Imaging, 2012, 39 : 408 - 415
  • [2] The Effects of Device-Based Cardiac Contractility Modulation Therapy on Left Ventricle Global Longitudinal Strain and Myocardial Mechano-Energetic Efficiency in Patients with Heart Failure with Reduced Ejection Fraction
    Masarone, Daniele
    Kittleson, Michelle M.
    De Vivo, Stefano
    D'Onofrio, Antonio
    Ammendola, Ernesto
    Nigro, Gerardo
    Contaldi, Carla
    Martucci, Maria L.
    Errigo, Vittoria
    Pacileo, Giuseppe
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (19)
  • [3] Heart failure monitoring with a cardiac resynchronization therapy device-based cardiac contractility sensor: A case series
    Mansourati J.
    Heurteau M.
    Abaléa J.
    Journal of Medical Case Reports, 8 (1)
  • [4] Device therapy in chronic heart failure: a case of hypertrophic cardiomyopathy treated with cardiac contractility modulation therapy
    Gragnano, Felice
    Munciguerra, Orlando
    Iacono, Agostino Mattera
    Brignoli, Marcello
    Chianese, Raffaele
    Limongelli, Giuseppe
    Viscusi, Miguel
    Calabro, Paolo
    GIORNALE ITALIANO DI CARDIOLOGIA, 2022, 23 (12) : 23S - 26S
  • [5] Established and Emerging Device Therapy in Heart Failure: Cardiac Contractility Modulation
    Haloot, Justin
    Chelu, Mihail G.
    TEXAS HEART INSTITUTE JOURNAL, 2023, 50 (06)
  • [6] Cardiac contractility modulation in patients with heart failure refractory to medical therapy
    Radiberger, R.
    Guba, B.
    Adlbrecht, C.
    KARDIOLOGE, 2009, 3 (01): : 51 - 54
  • [7] The Efficacy of Cardiac Contractility Modulation for Treating Patients with Heart Failure
    Zheng, Ningning
    Fu, Yongbing
    Xu, Mingzhu
    Ling, Lin
    Jiang, Tingbo
    Xue, Feng
    CARDIOVASCULAR ENGINEERING AND TECHNOLOGY, 2025, 16 (01) : 108 - 115
  • [8] Cardiac contractility modulation in patients with advanced heart failure
    Kahwash, Rami
    Burkhoff, Daniel
    Abraham, William T.
    EXPERT REVIEW OF CARDIOVASCULAR THERAPY, 2013, 11 (05) : 635 - 645
  • [9] Cardiac Resynchronization Therapy and Cardiac Contractility Modulation in Patients with Advanced Heart Failure How to Select the Right Candidate?
    Abraham, William T.
    HEART FAILURE CLINICS, 2021, 17 (04) : 599 - 606
  • [10] Cardiac contractility modulation therapy in advanced systolic heart failure
    Lyon, Alexander R.
    Samara, Michael A.
    Feldman, David S.
    NATURE REVIEWS CARDIOLOGY, 2013, 10 (10) : 584 - 598