Miniature pH sensor based on thin-core fiber Mach-Zehnder interferometer

被引:0
|
作者
Zhou, Menghui [1 ]
Dong, Xinyong [1 ]
Ma, Qifei [1 ]
Chan, Chi Chiu [2 ]
机构
[1] China Jiliang Univ, Inst Optoelect Technol, Hangzhou 310018, Peoples R China
[2] Nanyang Technol Univ, Sch Chem & Biomed Engn, Div Bioengn, Singapore 637457, Singapore
基金
中国国家自然科学基金;
关键词
Optical fiber sensors; thin-core fibers; pH sensors; Mach-Zehnder interferometer;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A miniature pH sensor by using a tapered thin-core optical fiber based Mach-Zehnder interferometer coated with a pH sensitive film is demonstrated. Polyvinyl alcohol (PVA) and polyacrylic acid (PAA) were used to form a membrane structure on the taper by laminating self-assembly technique. By measuring wavelength change of the interference pattern or optical intensity, we achieved high sensitivity pH value measurement up to 2.06 nm/pH unit. The proposed sensor has small size, simple structure, good stability and a relatively short response time less than 52 s.
引用
收藏
页数:3
相关论文
共 50 条
  • [1] Thin-core fiber-based Mach-Zehnder interferometer sensor for monitoring temperature, pressure, and humidity
    Hu, Chuan-ju
    Jiang, Chao
    Li, Li
    Deng, Long-feng
    Gao, Jia-wei
    Sun, Si-mei
    Cao, Ting-shui
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 2024, 52 (05) : 536 - 554
  • [2] Optical fiber strain and temperature sensor based on an in-line Mach-Zehnder interferometer using thin-core fiber
    Sun, Miao
    Xu, Ben
    Dong, Xinyong
    Li, Yi
    OPTICS COMMUNICATIONS, 2012, 285 (18) : 3721 - 3725
  • [3] High-Sensitivity Mach-Zehnder Interferometric Curvature Fiber Sensor Based on Thin-Core Fiber
    Fu, Haiwei
    Zhao, Na
    Shao, Min
    Li, Huidong
    Gao, Hong
    Liu, Qinpeng
    Yong, Zhen
    Liu, Yinggang
    Qiao, Xueguang
    IEEE SENSORS JOURNAL, 2015, 15 (01) : 520 - 525
  • [4] Sensitivity-enhanced refractive index sensor by using tapered thin-core fiber based inline Mach-Zehnder interferometer
    Shi, Jie
    Xiao, Shilin
    Bi, Meihua
    OPTICAL SENSORS AND BIOPHOTONICS III, 2011, 8311
  • [5] Sensitivity-enhanced refractive index sensor by using tapered thin-core fiber based inline Mach-Zehnder interferometer
    Shi, Jie
    Xiao, Shilin
    Bi, Meihua
    2011 ASIA COMMUNICATIONS AND PHOTONICS CONFERENCE AND EXHIBITION (ACP), 2012,
  • [6] Carboxymethyl Cellulose/Graphene Oxide Composite Film-Coated Humidity Sensor Based on Thin-Core Fiber Mach-Zehnder Interferometer
    Liu, Wei
    Zhang, Fan
    Yan, Xin
    Wang, Fang
    Zhang, Xuenan
    Suzuki, Takenobu
    Ohishi, Yasutake
    Cheng, Tonglei
    IEEE SENSORS JOURNAL, 2021, 21 (21) : 23767 - 23775
  • [7] A Novel Polyaniline/Graphene Oxide Composite Film-Coated Humidity Sensor Based on a Mach-Zehnder Interferometer With Thin-Core Fiber
    Huang, Xinyue
    Wang, Shuifeng
    Xie, Jingang
    Zhang, Ziyang
    Wu, Wei
    Li, Bangxing
    Xia, Tian
    IEEE SENSORS JOURNAL, 2024, 24 (13) : 20629 - 20637
  • [8] Refractive Index Measurement Based on Thin-Core Fiber In-Line Mach-Zehnder Interferometer and Differential Intensity Demodulation
    Cai, Xun
    Pan, Pan
    Chen, Sijie
    Wang, Haoran
    Fu, Hongyan
    IEEE PHOTONICS JOURNAL, 2022, 14 (06):
  • [9] Miniature Fiber Mach-Zehnder Interferometer Using a Polymer Filled Hollow Core Fiber
    Wu, Meng-Shan
    Luo, Shi-Hong
    Lee, Cheng-Ling
    Lee, Chung-Fen
    2017 OPTO-ELECTRONICS AND COMMUNICATIONS CONFERENCE (OECC) AND PHOTONICS GLOBAL CONFERENCE (PGC), 2017,
  • [10] An in-line Mach-Zehnder Interferometer Using Thin-core Fiber for Ammonia Gas Sensing With High Sensitivity
    Huang, Xinyue
    Li, Xueming
    Yang, Jianchun
    Tao, Chuanyi
    Guo, Xiaogang
    Bao, Hebin
    Yin, Yanjun
    Chen, Huifei
    Zhu, Yuhua
    SCIENTIFIC REPORTS, 2017, 7