A self-sampling-and-flow biosensor for continuous monitoring

被引:4
作者
Zhang, FH
Kim, JS
Cui, G
Sig, G
Cha, GS
Nam, H
机构
[1] Kwangwoon Univ, Dept Chem, Seoul 139701, South Korea
[2] iSENS Inc, Seoul 139845, South Korea
关键词
self-sampling-and-flow biosensor; double-sided microporous gold electrodes; biosensor; continuous glucose monitoring;
D O I
10.1002/elan.200403141
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A self-sampling-and-flow biosensor was fabricated by sandwiching a nitrocellulose strip on the working electrode side of the double-sided microporous gold electrodes and a wicking pad on the counter electrode side. The double-sided microporous electrodes were formed by plasma sputtering of gold on a porous nylon substrate. Sample was taken up to the enzyme-immobilized working electrode by the capillary action of the front nitrocellulose strip dipped into the sample solution, analyzed electrochemically at the enzyme-immobilized electrode, and diffuses out to the backside wicking pad through the micropores of the electrodes, constituting a complete flow cell device with no mechanical liquid-transporting device. Biosensor was formed by co-immobilizing the glucose oxidase and electron transfer mediator (ferrocene acetic acid) on the thioctic acid self-assembled monolayer-modified working electrode. A typical response time of the biosensor was about 5 min with the sensitivity of 2.98 nA/mM glucose, providing linear response up to 22.5 mM. To demonstrate the use of self-sampling-and-flow biosensor, the consumption rate of glucose in the presence of yeast was monitored for five days.
引用
收藏
页码:668 / 673
页数:6
相关论文
共 26 条
  • [1] Development of a multiparametric analyser based on ISFET sensors applied to process control in the wine industry
    Artigas, J
    Jiménez, C
    Domínguez, C
    Mínguez, S
    Gonzalo, A
    Alonso, J
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2003, 89 (1-2) : 199 - 204
  • [2] Reproducible fabrication of miniaturized glucose sensors: preparation of sensing membranes for continuous monitoring
    Chung, TD
    Jeong, RA
    Kang, SK
    Kim, HC
    [J]. BIOSENSORS & BIOELECTRONICS, 2001, 16 (9-12) : 1079 - 1087
  • [3] Comparison of spectrophotometric and potentiometric detection for the determination of water using Karl!Fischer method under flow injection analysis conditions
    Dantan, N
    Kröning, S
    Frenzel, W
    Küppers, S
    [J]. ANALYTICA CHIMICA ACTA, 2000, 420 (01) : 133 - 142
  • [4] DAUN C, 1994, ANAL CHEM, V66, P1369
  • [5] DAUN C, 1995, MIKROCHIM ACTA, V117, P195
  • [6] Competitive nonseparation electrochemical enzyme binding immunoassay (NEEIA) for small molecule detection
    Ducey, MW
    Smith, AM
    Guo, XA
    Meyerhoff, ME
    [J]. ANALYTICA CHIMICA ACTA, 1997, 357 (1-2) : 5 - 12
  • [7] Electrooxidative polymerization of phenothiazine derivatives on screen-printed carbon electrode and its application to determine NADH in flow injection analysis system
    Gao, Q
    Wang, WD
    Ma, Y
    Yang, XR
    [J]. TALANTA, 2004, 62 (03) : 477 - 482
  • [8] Shuttle electron transfer in tethered mediator biosensor
    Gorelik, LY
    Jonson, M
    Shekhter, RI
    Voinova, MV
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2001, 80 (03) : 179 - 182
  • [9] Hand-held amperometric sensor for saliva and other oral fluid-based diagnostics
    Ivnitski, D
    Sitdykov, R
    Ivnitski, N
    [J]. ANALYTICA CHIMICA ACTA, 2004, 504 (02) : 265 - 269
  • [10] Non-invasive electrochemical hand-held biosensor as diagnostic indicator of dental diseases
    Ivnitski, D
    Sitdikov, R
    Ivnitski, N
    [J]. ELECTROCHEMISTRY COMMUNICATIONS, 2003, 5 (03) : 225 - 229