Comparison of glomerular filtration rate measurements with two plasma and single plasma sample methods in renal transplant cases with stable renal graft functions

被引:0
|
作者
Oner, Ali Ozan [1 ]
Aydin, Funda [2 ]
Ipekci, Tumay [3 ]
Sipahi, Murat [2 ]
Suleymanlar, Gultekin [4 ]
Gungor, Firat [2 ]
机构
[1] Afyon Kocatepe Univ, Sch Med, Dept Nucl Med, Afyon, Turkey
[2] Akdeniz Univ, Sch Med, Dept Nucl Med, TR-07058 Antalya, Turkey
[3] Baskent Univ, Sch Med, Alanya Practice & Res Ctr, Dept Urol, Alanya, Turkey
[4] Akdeniz Univ, Sch Med, Dept Internal Med, Div Nephrol, TR-07058 Antalya, Turkey
关键词
Glomerular filtration rate; Renal transplantation; Single plasma sample method; Two plasma sample method; PREDICTED CREATININE CLEARANCE; CHRONIC KIDNEY-DISEASE; DIABETIC-NEPHROPATHY; TC-99M-DTPA; CR-51-EDTA; RADIONUCLIDES; GUIDELINES; INJECTION; INULIN; DTPA;
D O I
10.1007/s12149-015-0954-x
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This study was planned to determine the efficacies of single plasma sample methods (SPSMs) in indicating glomerular filtration rate (GFR) by taking two plasma sample method (TPSM) as reference in the determination of the GFR in cases with clinically stable renal transplantation. Ninety-six renal transplantation cases (33 female, 63 male; age interval 18-67, mean age 37.46 +/- A 11.81 years) progressing stably clinically and as laboratory, with minimum 6 months after transplantation were included in the study. The GFR values of the cases were measured with SPSM and TPSM. It is observed that all SPSMs have a strong correlation with TPSM. Highest correlation was observed between Groth&Aasted SPSM and TPSM GFR (intraclass correlation coefficient: 0.965). In the analyses performed by using the Bland-Altman analysis, GFR values calculated by all SPSMs were concordant to the TPSM which is the gold standard method in 95 % confidence interval (average +/- A 1.96 standard deviation) and were within the clinically acceptable limits. The narrowest concordance interval was obtained between Groth&Aasted Tc-99 m DTPA SPSM and Tc-99 m DTPA TPSM..Besides, we have obtained the minimum bias and precision value by the Groth&Aasted method. As a result; we can see that all the SPSMs give reliable results in measuring GFR in cases with renal transplantation; besides, we suggest Groth&Aasted method as the first option.
引用
收藏
页码:359 / 365
页数:7
相关论文
共 50 条
  • [31] Prospective Comparison of Equations Based on Creatinine and Cystatin C for the Glomerular Filtration Rate Estimation in Chinese Renal Transplant Recipients
    Tang, Z.
    Tao, J.
    Sun, L.
    Han, Z.
    Chen, H.
    Huang, Z.
    Zhou, W.
    Zhao, C.
    Fei, S.
    Que, H.
    Li, Y.
    Tan, R.
    Gu, M.
    TRANSPLANTATION PROCEEDINGS, 2018, 50 (01) : 85 - 91
  • [32] Glomerular filtration rate in dogs as estimated via plasma clearance of inulin and iohexol and use of limited-sample methods
    Heiene, Reidun
    Eliassen, Knut A.
    Risoen, Unni
    Neal, Larry A.
    Cowgill, Larry D.
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 2010, 71 (09) : 1100 - 1107
  • [33] Estimated one-year glomerular filtration rate is the best predictor of long-term graft function following renal transplant
    Salvadori, M
    Rosati, A
    Bock, A
    Chapman, J
    Dussol, B
    Fritsche, L
    Kliem, V
    Lebranchu, Y
    Oppenheimer, F
    Pohanka, E
    Tufveson, G
    Bertoni, E
    TRANSPLANTATION, 2006, 81 (02) : 202 - 206
  • [34] Renal evaluation in the healthy green iguana (Iguana iguana):: Assessment of plasma biochemistry, glomerular filtration rate, and endoscopic biopsy
    Hernandez-Divers, SJ
    Stahl, SJ
    Stedman, NL
    Hernandez-Divers, SM
    Schumacher, J
    Hanley, CS
    Wilson, H
    Vidyashankar, AN
    Zhao, Y
    Rumbeiha, WK
    JOURNAL OF ZOO AND WILDLIFE MEDICINE, 2005, 36 (02) : 155 - 168
  • [35] Comparison of methods for determination of glomerular filtration rate: Tc-99m-DTPA renography, predicted creatinine clearance method and plasma sample method
    Itoh, K
    ANNALS OF NUCLEAR MEDICINE, 2003, 17 (07) : 561 - 565
  • [36] The reliability of glomerular filtration rate measured from plasma clearance: a multi-centre study of 1,878 healthy potential renal transplant donors
    A. Michael Peters
    Bethany Howard
    Mark D. J. Neilly
    Nagabhushan Seshadri
    Ravin Sobnack
    Claire A. Hooker
    Andrew Irwin
    Hayley Snelling
    Thomas Gruning
    Laura Perry
    Neva H. Patel
    Richard S. Lawson
    Gregory Shabo
    Nigel Williams
    Surendra Dave
    Mark C Barnfield
    European Journal of Nuclear Medicine and Molecular Imaging, 2012, 39 : 715 - 722
  • [37] Comparison of methods for determination of glomerular filtration rate: Tc-99m-DTPA renography, predicted creatinine clearance method and plasma sample method
    Kazuo Itoh
    Annals of Nuclear Medicine, 2003, 17 : 561 - 565
  • [38] Retrospective study of renal distribution volume with DTPA-Tc-99m: Performance of single plasma method for glomerular filtration rate estimation.
    Legendre, JM
    Cledes, J
    Morin, JF
    Morin, PP
    MEDECINE NUCLEAIRE, 1997, 21 (05): : 315 - 321
  • [39] Agreement between two routine methods of estimation of glomerular filtration rate in patients with advanced and terminal chronic renal failure
    Garcia-Naveiro, R
    Rodriguez-Carmona, A
    Pérez-Fontán, M
    CLINICAL NEPHROLOGY, 2005, 64 (04) : 271 - 280
  • [40] Measurement of glomerular filtration rate and effective renal plasma flow in the conscious beagle dog by single intravenous bolus of iohexol and p-aminohippuric acid
    Laroute, V
    Lefebvre, HP
    Costes, G
    Toutain, PL
    JOURNAL OF PHARMACOLOGICAL AND TOXICOLOGICAL METHODS, 1999, 41 (01) : 17 - 25