Comparison of glomerular filtration rate measurements with two plasma and single plasma sample methods in renal transplant cases with stable renal graft functions

被引:0
|
作者
Oner, Ali Ozan [1 ]
Aydin, Funda [2 ]
Ipekci, Tumay [3 ]
Sipahi, Murat [2 ]
Suleymanlar, Gultekin [4 ]
Gungor, Firat [2 ]
机构
[1] Afyon Kocatepe Univ, Sch Med, Dept Nucl Med, Afyon, Turkey
[2] Akdeniz Univ, Sch Med, Dept Nucl Med, TR-07058 Antalya, Turkey
[3] Baskent Univ, Sch Med, Alanya Practice & Res Ctr, Dept Urol, Alanya, Turkey
[4] Akdeniz Univ, Sch Med, Dept Internal Med, Div Nephrol, TR-07058 Antalya, Turkey
关键词
Glomerular filtration rate; Renal transplantation; Single plasma sample method; Two plasma sample method; PREDICTED CREATININE CLEARANCE; CHRONIC KIDNEY-DISEASE; DIABETIC-NEPHROPATHY; TC-99M-DTPA; CR-51-EDTA; RADIONUCLIDES; GUIDELINES; INJECTION; INULIN; DTPA;
D O I
10.1007/s12149-015-0954-x
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This study was planned to determine the efficacies of single plasma sample methods (SPSMs) in indicating glomerular filtration rate (GFR) by taking two plasma sample method (TPSM) as reference in the determination of the GFR in cases with clinically stable renal transplantation. Ninety-six renal transplantation cases (33 female, 63 male; age interval 18-67, mean age 37.46 +/- A 11.81 years) progressing stably clinically and as laboratory, with minimum 6 months after transplantation were included in the study. The GFR values of the cases were measured with SPSM and TPSM. It is observed that all SPSMs have a strong correlation with TPSM. Highest correlation was observed between Groth&Aasted SPSM and TPSM GFR (intraclass correlation coefficient: 0.965). In the analyses performed by using the Bland-Altman analysis, GFR values calculated by all SPSMs were concordant to the TPSM which is the gold standard method in 95 % confidence interval (average +/- A 1.96 standard deviation) and were within the clinically acceptable limits. The narrowest concordance interval was obtained between Groth&Aasted Tc-99 m DTPA SPSM and Tc-99 m DTPA TPSM..Besides, we have obtained the minimum bias and precision value by the Groth&Aasted method. As a result; we can see that all the SPSMs give reliable results in measuring GFR in cases with renal transplantation; besides, we suggest Groth&Aasted method as the first option.
引用
收藏
页码:359 / 365
页数:7
相关论文
共 50 条
  • [21] Comparison of Four Methods for Measuring Glomerular Filtration Rate by Inulin Clearance in Healthy Individuals and Patients with Renal Failure
    Hernandez Ocampo, J.
    Torres Rosales, A.
    Rodriguez Castellanos, F.
    NEFROLOGIA, 2010, 30 (03): : 324 - 330
  • [22] A comparison of different methods for the determination of glomerular filtration rate in elderly patients with chronic renal failure
    Beyza Macunluoğlu
    İbrahim Gökçe
    Aydın Atakan
    Münir Demirci
    Elif Arı
    Ahmet Topuzoğlu
    Ali Borazan
    International Urology and Nephrology, 2011, 43 : 257 - 263
  • [23] Comparison of 12-Hour Creatinine Clearance and Estimated Glomerular Filtration Rate in Renal Transplant Recipients
    Kumar, Rakesh
    Pendyala, Prashant
    Attwood, Kris
    Gray, Vanessa
    Venuto, Rocco
    Tornatore, Kathleen
    RENAL FAILURE, 2013, 35 (03) : 333 - 337
  • [24] Glomerular filtration rate determination in diabetic patients using iohexol clearance - comparison of single and multiple plasma sampling methods
    Chowdhury, TA
    Dyer, PH
    Bartlett, WA
    Legge, ES
    Durbin, SM
    Barnett, AH
    Bain, SC
    CLINICA CHIMICA ACTA, 1998, 277 (02) : 153 - 158
  • [25] Plasma symmetric dimethylarginine and creatinine concentrations and glomerular filtration rate in cats with normal and decreased renal function
    Brans, Marleen
    Daminet, Sylvie
    Mortier, Femke
    Duchateau, Luc
    Lefebvre, Herve P.
    Paepe, Dominique
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2021, 35 (01) : 303 - 311
  • [26] Urinary apo(a) excretion is not altered by changes in glomerular filtration rate and renal plasma flow in healthy males
    Kostner, K
    Clodi, M
    Bodlaj, G
    Hoffmann, U
    Hermann, K
    Maurer, G
    Pacher, R
    Hörl, WH
    WIENER KLINISCHE WOCHENSCHRIFT, 2000, 112 (03) : 121 - 125
  • [27] The reliability of glomerular filtration rate measured from plasma clearance: a multi-centre study of 1,878 healthy potential renal transplant donors
    Peters, A. Michael
    Howard, Bethany
    Neilly, Mark D. J.
    Seshadri, Nagabhushan
    Sobnack, Ravin
    Hooker, Claire A.
    Irwin, Andrew
    Snelling, Hayley
    Gruning, Thomas
    Perry, Laura
    Patel, Neva H.
    Lawson, Richard S.
    Shabo, Gregory
    Williams, Nigel
    Dave, Surendra
    Barnfield, Mark C.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 (04) : 715 - 722
  • [28] Impact of Body Mass Index on Gates Method of Glomerular Filtration Rate Estimation: A Comparative Study with Single Plasma Sample Method
    Nautiyal, Amit
    Mukherjee, Anirban
    Mitra, Deepanjan
    Chatterjee, Piyali
    Roy, Anindya
    INDIAN JOURNAL OF NUCLEAR MEDICINE, 2019, 34 (01): : 19 - 23
  • [29] Measurement of glomerular filtration rate, renal plasma flow, and endogenous creatinine clearance in cheetahs (Acinonyx jubatus jubatus)
    Holder, EH
    Citino, SB
    Businga, N
    Cartier, L
    Brown, SA
    JOURNAL OF ZOO AND WILDLIFE MEDICINE, 2004, 35 (02) : 175 - 178
  • [30] Assessing glomerular filtration rate in renal transplant recipients by estimates derived from serum measurements of creatinine and cystatin C
    Risch, L
    Huber, AR
    CLINICA CHIMICA ACTA, 2005, 356 (1-2) : 204 - 211