Comparison of glomerular filtration rate measurements with two plasma and single plasma sample methods in renal transplant cases with stable renal graft functions

被引:0
|
作者
Oner, Ali Ozan [1 ]
Aydin, Funda [2 ]
Ipekci, Tumay [3 ]
Sipahi, Murat [2 ]
Suleymanlar, Gultekin [4 ]
Gungor, Firat [2 ]
机构
[1] Afyon Kocatepe Univ, Sch Med, Dept Nucl Med, Afyon, Turkey
[2] Akdeniz Univ, Sch Med, Dept Nucl Med, TR-07058 Antalya, Turkey
[3] Baskent Univ, Sch Med, Alanya Practice & Res Ctr, Dept Urol, Alanya, Turkey
[4] Akdeniz Univ, Sch Med, Dept Internal Med, Div Nephrol, TR-07058 Antalya, Turkey
关键词
Glomerular filtration rate; Renal transplantation; Single plasma sample method; Two plasma sample method; PREDICTED CREATININE CLEARANCE; CHRONIC KIDNEY-DISEASE; DIABETIC-NEPHROPATHY; TC-99M-DTPA; CR-51-EDTA; RADIONUCLIDES; GUIDELINES; INJECTION; INULIN; DTPA;
D O I
10.1007/s12149-015-0954-x
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This study was planned to determine the efficacies of single plasma sample methods (SPSMs) in indicating glomerular filtration rate (GFR) by taking two plasma sample method (TPSM) as reference in the determination of the GFR in cases with clinically stable renal transplantation. Ninety-six renal transplantation cases (33 female, 63 male; age interval 18-67, mean age 37.46 +/- A 11.81 years) progressing stably clinically and as laboratory, with minimum 6 months after transplantation were included in the study. The GFR values of the cases were measured with SPSM and TPSM. It is observed that all SPSMs have a strong correlation with TPSM. Highest correlation was observed between Groth&Aasted SPSM and TPSM GFR (intraclass correlation coefficient: 0.965). In the analyses performed by using the Bland-Altman analysis, GFR values calculated by all SPSMs were concordant to the TPSM which is the gold standard method in 95 % confidence interval (average +/- A 1.96 standard deviation) and were within the clinically acceptable limits. The narrowest concordance interval was obtained between Groth&Aasted Tc-99 m DTPA SPSM and Tc-99 m DTPA TPSM..Besides, we have obtained the minimum bias and precision value by the Groth&Aasted method. As a result; we can see that all the SPSMs give reliable results in measuring GFR in cases with renal transplantation; besides, we suggest Groth&Aasted method as the first option.
引用
收藏
页码:359 / 365
页数:7
相关论文
共 50 条
  • [1] Comparison of glomerular filtration rate measurements with two plasma and single plasma sample methods in renal transplant cases with stable renal graft functions
    Ali Ozan Oner
    Funda Aydin
    Tumay Ipekci
    Murat Sipahi
    Gultekin Suleymanlar
    Firat Gungor
    Annals of Nuclear Medicine, 2015, 29 : 359 - 365
  • [2] Clinical value of cystatin C and beta-trace protein in glomerular filtration rate in renal transplant cases with stable renal graft functions: comparison by the 99mTc-DTPA plasma sample method
    Oner, Ali Ozan
    Aydin, Funda
    Demirelli, Serkan
    Budak, Evrim S.
    Davran, Fatih
    Akbas, Halide
    Kocak, Huseyin
    Suleymanlar, Gultekin
    Gungor, Firat
    NUCLEAR MEDICINE COMMUNICATIONS, 2014, 35 (07) : 733 - 744
  • [3] Comparison of renal dynamic imaging and two plasma sample method in determining glomerular filtration rate in patients with diabetic nephropathy
    Li, Ming-Hao
    Jiang, Nan
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2016, 9 (10): : 19919 - 19924
  • [4] Comparison of glomerular filtration rate measurements with the two plasma sample and single plasma sample, gamma camera Gates, creatinine clearance, and prediction equation methods in potential kidney donors with normal renal function
    Aydin, Funda
    Gungor, Firat
    Cengiz, Arzu Kin
    Tuncer, Murat
    Mahsereci, Erkan
    Ozdem, Sadi
    Cenkci, Mehmet
    Karayalcin, Binnur
    NUCLEAR MEDICINE COMMUNICATIONS, 2008, 29 (02) : 157 - 165
  • [5] Measurement of glomerular filtration rate in renal transplant recipients: A comparison of methods
    Mourad, A
    Carney, S
    Gillies, A
    Hibberd, A
    Trevillian, P
    Nanra, R
    NEPHROLOGY, 2002, 7 (02) : 77 - 82
  • [6] Comparison of glomerular filtration rate measurements with the two-plasma sample technique using Tc-99m DTPA and other methods in donor candidates for renal transplantation
    Ayan, Arif Kursad
    Varoglu, Erhan
    Keles, Mustafa
    Seven, Bedri
    Uyanik, Abdullah
    Orsal, Ebru
    TURKISH JOURNAL OF MEDICAL SCIENCES, 2016, 46 (04) : 1025 - 1032
  • [7] Comparison of glomerular filtration rate measured by plasma sample technique, Cockroft Gault method and Gates' method in voluntary kidney donors and renal transplant recipients
    Hephzibah, Julie
    Shanthly, Nylla
    Oommen, Regi
    INDIAN JOURNAL OF NUCLEAR MEDICINE, 2013, 28 (03): : 144 - 151
  • [8] A Comparison of the Accuracy of Different Single Plasma Sample Methods for Measuring Glomerular Filtration Rate Using 51Cr-EDTA in Children
    Ha S.
    Lee J.J.
    Nuclear Medicine and Molecular Imaging, 2018, 52 (4) : 293 - 302
  • [9] A Pilot Study to Evaluate Renal Hemodynamics in Cirrhosis by Simultaneous Glomerular Filtration Rate, Renal Plasma Flow, Renal Resistive Indices and Biomarkers Measurements
    Mindikoglu, Ayse L.
    Dowling, Thomas C.
    Wong-You-Cheong, Jade J.
    Christenson, Robert H.
    Magder, Laurence S.
    Hutson, William R.
    Seliger, Stephen L.
    Weir, Matthew R.
    AMERICAN JOURNAL OF NEPHROLOGY, 2014, 39 (06) : 543 - 552
  • [10] A general equation for estimating glomerular filtration rate from a single plasma sample
    Fleming, JS
    Persaud, L
    Zivanovic, MA
    NUCLEAR MEDICINE COMMUNICATIONS, 2005, 26 (08) : 743 - 748