The usefulness of dual mobility cups in primary total hip arthroplasty patients at a risk of dislocation

被引:13
作者
Moon, Nam Hoon [1 ]
Do, Min Uk [2 ]
Kim, Jung Shin [2 ]
Seo, Jae Seung [2 ]
Shin, Won Chul [2 ]
机构
[1] Pusan Natl Univ Hosp, Dept Orthopaed Surg, Busan, South Korea
[2] Pusan Natl Univ, Sch Med, Res Inst Convergence Biomed Sci & Technol, Dept Orthopaed Surg,Yangsan Hosp, 20 Geumo Ro, Yangsan 626770, Gyeongsangnam D, South Korea
关键词
FEMORAL-NECK; OUTCOMES; SOCKET;
D O I
10.1038/s41598-022-04774-2
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
This study aimed to evaluate the early results of primary total hip arthroplasty (THA) using dual mobility (DM) cups in patients at a risk of dislocation and compare them with that of fixed bearing (FB) THA. This retrospective study included patients who had undergone primary THA between January 2016 and December 2018 and were at a risk of dislocation. A propensity score-matched analysis was conducted for 63 THA procedures with vitamin-E infused highly cross-linked polyethylene (VEPE) DM bearing and 63 THA procedures performed with FB from the same manufacturer for a mean follow-up period of 3.1 and 3.5 years, respectively. The radiologic outcomes at the last follow-up and incidence of postoperative complications were evaluated and compared statistically between the two groups. The modified Harris hip score (mHHS) was used to assess patient-reported outcomes. Postoperative dislocation occurred in 4 cases (6.3%) in the FB group, but did not occur in the DM group (p = 0.042). There was no difference in the radiologic outcomes and postoperative complications between the two groups. The mHHS at the last follow-up showed satisfactory outcomes in both the groups (DM group, 90.5; FB group, 88.1), without a statistical difference between the groups. The early results of THA using VEPE DM bearing showed better outcomes than that of THA with FB for patients at a risk of dislocation. A longer follow-up period is recommended to assess the stability and overall outcomes.
引用
收藏
页数:7
相关论文
共 20 条
[1]   Early results of total hip arthroplasty using dual-mobility cup in patients with osteonecrosis of the femoral head [J].
Assi, Chahine ;
Kheir, Nadim ;
Samaha, Camille ;
Kouyoumjian, Pascal ;
Yammine, Kaissar .
SICOT-J, 2018, 4
[2]   Mortality Rate and Mid-Term Outcomes of Total Hip Arthroplasty Using Dual Mobility Cups for the Treatment of Femoral Neck Fractures in a Middle Eastern Population [J].
Assi, Chahine C. ;
Barakat, Hanane B. ;
Caton, Jacques H. ;
Najjar, Elie N. ;
Samaha, Camille T. ;
Yammine, Kaissar F. .
JOURNAL OF ARTHROPLASTY, 2019, 34 (02) :333-337
[3]   Statistical Criteria for Selecting the Optimal Number of Untreated Subjects Matched to Each Treated Subject When Using Many-to-One Matching on the Propensity Score [J].
Austin, Peter C. .
AMERICAN JOURNAL OF EPIDEMIOLOGY, 2010, 172 (09) :1092-1097
[4]  
Bassiony AA., 2020, OPEN J TRAUMA, V4, P32
[5]   The dislocating hip - What to do, what to do [J].
Bourne, RB ;
Mehin, R .
JOURNAL OF ARTHROPLASTY, 2004, 19 (04) :111-114
[6]   Primary total hip arthroplasty with dual mobility socket to prevent dislocation: a 22-year follow-up of 240 hips [J].
Boyer, Bertrand ;
Philippot, Remi ;
Geringer, Jean ;
Farizon, Frederic .
INTERNATIONAL ORTHOPAEDICS, 2012, 36 (03) :511-518
[7]   The Epidemiology of Revision Total Hip Arthroplasty in the United States [J].
Bozic, Kevin J. ;
Kurtz, Steven M. ;
Lau, Edmund ;
Ong, Kevin ;
Vail, Thomas P. ;
Berry, Daniel J. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (01) :128-133
[8]   Assessment of Damage on a Dual Mobility Acetabular System [J].
D'Apuzzo, Michele R. ;
Koch, Chelsea N. ;
Esposito, Christina I. ;
Elpers, Marcella E. ;
Wright, Timothy M. ;
Westrich, Geoffrey H. .
JOURNAL OF ARTHROPLASTY, 2016, 31 (08) :1828-1835
[9]   Total Hip Arthroplasty Patients With Fixed Spinopelvic Alignment Are at Higher Risk of Hip Dislocation [J].
Esposito, Christina I. ;
Carroll, Kaitlin M. ;
Sculco, Peter K. ;
Padgett, Douglas E. ;
Jerabek, Seth A. ;
Mayman, David J. .
JOURNAL OF ARTHROPLASTY, 2018, 33 (05) :1449-1454
[10]   Abductor Biomechanics Clinically Impact the Total Hip Arthroplasty Dislocation Rate A Prospective Long-Term Study [J].
Garcia-Rey, Eduardo ;
Garcia-Cimbrelo, Eduardo .
JOURNAL OF ARTHROPLASTY, 2016, 31 (02) :484-490