Orbit Analysis From a Stray Flux Full Spectrum for Induction Machine Fault Detection

被引:12
作者
Lamim Filho, Paulo C. M. [1 ]
Rabelo Baccarini, Lane M. [1 ]
Batista, Fabiano B. [2 ]
Araujo, Ana C. [1 ]
机构
[1] Univ Fed Sao Joao del Rei, Dept Elect Engn DEPEL, BR-36307352 Sao Joao Del Rei, Brazil
[2] Univ Fed Sao Joao del Rei, Dept Mech Engn DEMEC UFSJ, BR-36307352 Sao Joao Del Rei, Brazil
关键词
Full Spectrum; three-phase induction motor; flux coils; incipient fault diagnosis; STATOR WINDING FAULTS; ROTOR FAULTS; MOTORS; DIAGNOSIS;
D O I
10.1109/JSEN.2021.3074815
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Y Magnetic flux sensors in particular, combined with appropriate signal processing techniques, create excellent opportunities for extracting significant information for fault diagnosis of induction motors. Recent research has opened the possibility of simultaneously obtaining magnetic flux signals displaced approximately 90 degrees in time. This makes it possible to correlate the stray magnetic flux from different transducers. In this scenario, the Full Spectrum technique, widely used for vibration signals, can become a useful tool for displaying the relationship between different magnetic flux components in the frequency domain. Taking this into account, this work proposes the use of the filtered orbit, modified and obtained from the Full Spectrum, for interpreting the magnetic flux signals. This was done for the motor working under inter turn short circuits (three, six and nine turns short), unbalanced voltage fault or without fault conditions at different loads. Two characteristic frequencies of faults were considered, 180 Hz and 420 Hz. The experimental results showed the viability of the application of the technique and made it possible to identify the severity and the distinction of the faults studied as the orbital area and the direction of rotation were changed due to the presence of the fault. For example, for the incipient failure (three turns short), considering all loads, the orbit area at 180 Hz increased no less than 92% and the unbalanced voltage by no less than 885%. Additionally, the pattern of the orbit rotation at 420 Hz, was also affected by the operating condition of the motor under unbalanced voltage.
引用
收藏
页码:16152 / 16161
页数:10
相关论文
共 38 条
  • [1] [Anonymous], 1929, T AM I ELECT ENG, DOI DOI 10.1109/T-AIEE.1929.5055275
  • [2] Azizi B, 2018, 2018 5TH INTERNATIONAL CONFERENCE ON ELECTRICAL AND ELECTRONIC ENGINEERING (ICEEE), P445, DOI 10.1109/ICEEE2.2018.8391379
  • [3] Bachschmid N., 2004, J. Braz. Soc. Mech. Sci. & Eng., V26, P200
  • [4] An Empirical Demodulation for Electrical Fault Detection in Induction Motors
    Batista, Fabiano Bianchini
    Monteiro Lamim Filho, Paulo Cezar
    Pederiva, Robson
    Diniz Silva, Vinicius Augusto
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2016, 65 (03) : 559 - 569
  • [5] Non-Invasive Detection of Rotor Short-Circuit Fault in Synchronous Machines by Analysis of Stray Magnetic Field and Frame Vibrations
    Cuevas, Mauricio
    Romary, Raphael
    Lecointe, Jean-Philippe
    Jacq, Thierry
    [J]. IEEE TRANSACTIONS ON MAGNETICS, 2016, 52 (07)
  • [6] Broken Rotor Bars Detection in Induction Motors Running at Very Low Slip Using a Hall Effect Sensor
    Dias, Cleber Gustavo
    Pereira, Fabio Henrique
    [J]. IEEE SENSORS JOURNAL, 2018, 18 (11) : 4602 - 4613
  • [7] Generalized Likelihood Ratio Test Based Approach for Stator-Fault Detection in a PWM Inverter-Fed Induction Motor Drive
    Elbouchikhi, Elhoussin
    Amirat, Yassine
    Feld, Gilles
    Benbouzid, Mohamed
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2019, 66 (08) : 6343 - 6353
  • [8] Detection of Nonadjacent Rotor Faults in Induction Motors via Spectral Subtraction and Autocorrelation of Stray Flux Signals
    Enrique Iglesias-Martinez, Miguel
    Fernandez de Cordoba, Pedro
    Antonino-Daviu, Jose A.
    Alberto Conejero, J.
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2019, 55 (05) : 4585 - 4594
  • [9] Axial Stray Flux Sensor Proposal for Three-Phase Induction Motor Fault Monitoring by Means of Orbital Analysis
    Filho, Paulo C. M. Lamim
    Santos, Deivity C.
    Batista, Fabiano B.
    Baccarini, Lane M. R.
    [J]. IEEE SENSORS JOURNAL, 2020, 20 (20) : 12317 - 12325
  • [10] Induction Machine Bearing Fault Detection by Means of Statistical Processing of the Stray Flux Measurement
    Frosini, Lucia
    Harlisca, Ciprian
    Szabo, Lorand
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2015, 62 (03) : 1846 - 1854