Magnetic resonance imaging in patients with cardiac implantable electronic devices: A prospective study

被引:6
|
作者
Navarro-Valverde, Cristina [1 ]
Ramos-Maqueda, Javier [2 ]
Jose Romero-Reyes, M. [1 ]
Esteve-Ruiz, Irene [3 ]
Garcia-Medina, Dolores [1 ]
Pavon-Jimenez, Ricardo [1 ]
Rodriguez-Gomez, Cristobal [4 ]
Leal-Del-Ojo, Juan [5 ]
Cayuela, Aurelio [6 ]
Molano-Casimiro, Francisco J. [1 ]
机构
[1] Hosp Univ Valme, Dept Cardiol, Seville, Spain
[2] Hosp Clin Univ Lozano Blesa, Dept Cardiol, Arrhythmias Unit, Zaragoza, Spain
[3] Hosp Juan Ramon Jimenez, Dept Cardiol, Huelva, Spain
[4] Hosp Univ Valme, Dept Radiol, Seville, Spain
[5] Hosp Fatima, Dept Cardiol, Seville, Spain
[6] Hosp Univ Valme, Dept Publ Hlth Prevent & Hlth Promot, Seville, Spain
关键词
Pacemaker Implantable cardioverter-defibrillator; Magnetic resonance imaging; Safety; CARDIOVERTER-DEFIBRILLATORS; PACEMAKER; SAFETY; MRI; UTILITY; STRATEGIES; CARDIOLOGY; STATEMENT; ARTIFACT; PROTOCOL;
D O I
10.1016/j.mri.2022.05.004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: The number of patients with cardiac implantable electronic devices in whom magnetic resonance imaging (MRI) is indicated is constantly increasing. The potential risk of electromagnetic interference has limited its use and it is still contraindicated by the Food and Drug Administration in some cases. The aim of this study is to evaluate the safety and efficacy of MRI in these patients. Methods: A prospective registry comprising patients with a pacemaker (PM) or implantable cardioverterdefibrillator (ICD), MRI-conditional or not, who were candidates for MRI (at 1.5 T) with no suitable alternative diagnostic technique. All devices were programmed before the procedure and patients were monitored throughout the test. Clinical, electrical, and technical parameters were evaluated before and after MRI. Results: 147 MRI examinations (132 PM and 15 ICD) were performed. There were no clinical events or significant differences in the electrical parameters of the leads after MRI. A variation in the impedance of the ventricular leads was detected, although the difference was not clinically relevant. In one patient with a PM, a failure in release of the safety impulse was detected in the auto-threshold test, although the threshold was correctly determined. In 11 of the 17 thoracic MRIs, image artifacts were detected, preventing the diagnosis in two of them. Conclusions: In patients with cardiac implantable electronic devices, MRIs performed under a specific protocol has been shown to be safe in the short term even in the thoracic region, as well as interpretable in most cases.
引用
收藏
页码:9 / 15
页数:7
相关论文
共 50 条
  • [41] MRI of Patients with Cardiac Implantable Electronic Devices
    Martinez, Jessica A.
    Ennis, Daniel B.
    CURRENT CARDIOVASCULAR IMAGING REPORTS, 2019, 12 (07)
  • [42] Cardiac Implantable Electronic Device Safety during Magnetic Resonance Imaging
    Hwang, You Mi
    Kim, Jun
    Lee, Ji Hyun
    Kim, Minsu
    Nam, Gi-Byoung
    Choi, Kee-Joon
    Kim, You-Ho
    KOREAN CIRCULATION JOURNAL, 2016, 46 (06) : 804 - 810
  • [43] Magnetic resonance imaging in patients with cardiac implantable electronic devices in a cardio-oncology center
    Tajstra, Mateusz
    Dyrbus, Maciej
    Wojtynek, Elzbieta
    Wojtaszczyk, Adam
    Rutkowski, Tomasz
    Niedziela, Jacek
    Blachut, Aleksandra
    Jarzab, Michal
    Blamek, Slawomir
    Kurek, Anna
    Gorol, Jaroslaw
    Witek, Mateusz
    Skladowski, Krzysztof
    Gasior, Mariusz
    Bobek-Bilewicz, Barbara
    KARDIOLOGIA POLSKA, 2023, 81 (06) : 619 - 621
  • [44] Magnetic Resonance Myocardial Imaging in Patients With Implantable Cardiac Devices: Challenges, Techniques, and Clinical Applications
    Gut, Pauline
    Cochet, Hubert
    Stuber, Matthias
    Bustin, Aurelien
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2024, 41 (11):
  • [45] Magnetic Resonance Imaging in Patients With Implantable Cardiac Devices
    Sierra, Mark
    Machado, Christian
    REVIEWS IN CARDIOVASCULAR MEDICINE, 2008, 9 (04) : 232 - 238
  • [46] Magnetic resonance imaging in individuals with cardiovascular implantable electronic devices
    Roguin, Ariel
    Schwitter, Juerg
    Vahlhaus, Christian
    Lombardi, Massimo
    Brugada, Josep
    Vardas, Panos
    Auricchio, Angelo
    Priori, Silvia
    Sommer, Torsten
    EUROPACE, 2008, 10 (03): : 334 - 344
  • [47] Evidence to support magnetic resonance conditional labelling of all pacemaker and defibrillator leads in patients with cardiac implantable electronic devices
    Bhuva, Anish N.
    Moralee, Russell
    Brunker, Tamara
    Lascelles, Karen
    Cash, Lizette
    Patel, Kush P.
    Lowe, Martin
    Sekhri, Neha
    Alpendurada, Francisco
    Pennell, Dudley J.
    Schilling, Richard
    Lambiase, Pier D.
    Chow, Anthony
    Moon, James C.
    Litt, Harold
    Baksi, A. John
    Manisty, Charlotte H.
    EUROPEAN HEART JOURNAL, 2022, 43 (26) : 2469 - 2478
  • [48] Clinical impact of cardiovascular magnetic resonance with optimized myocardial scar detection in patients with cardiac implantable devices
    Bhuva, Anish N.
    Kellman, Peter
    Graham, Adam
    Ramlall, Manish
    Boubertakh, Redha
    Feuchter, Patricia
    Hawkins, Angela
    Lowe, Martin
    Lambiase, Pier D.
    Sekhri, Neha
    Schilling, Richard J.
    Moon, James C.
    Manisty, Charlotte H.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2019, 279 : 72 - 78
  • [49] Considerations for stress perfusion cardiac magnetic resonance imaging in patients with cardiac implantable electronic devices
    Chyou, Janice Y.
    Axel, Leon
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2022, 33 (10) : 2136 - 2138
  • [50] Cardiac magnetic resonance imaging at 1.5 T in patients with cardiac rhythm devices
    Buendia, Francisco
    Cano, Oscar
    Miguel Sanchez-Gomez, Juan
    Igual, Begona
    Osca, Joaquin
    Jose Sancho-Tello, Maria
    Olaguee, Jose
    Salvador, Antonio
    EUROPACE, 2011, 13 (04): : 533 - 538