Sol-gel-derived prussian blue-silicate amperometric glucose biosensor

被引:22
|
作者
Bharathi, S [1 ]
Lev, O [1 ]
机构
[1] Hebrew Univ Jerusalem, Fredy & Nadine Hermann Sch Appl Sci, IL-91904 Jerusalem, Israel
关键词
sol-gel; biosensor; Prussian blue; modified electrodes;
D O I
10.1385/ABAB:89:2-3:209
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
A new type of inorganic biosensor is introduced. The sensor comprises glucose oxidase enzymes encapsulated in a sol-gel-derived Prussian blue-silicate hybrid network. Glucose is detected by the biocatalytic reduction of oxygen followed by catalytic reduction of hydrogen peroxide by the Prussian blue catalyst. The sol-gel silicate entails a rigid encapsulating matrix, the Prussian blue provides chemical catalysis and charge mediation from the reduction site to the supporting electrode, and the enzyme is responsible for the biocatalysis. The feasibility of a dual optical/electrochemical mode of analysis is also demonstrated.
引用
收藏
页码:209 / 216
页数:8
相关论文
共 50 条
  • [31] Amperometric Glucose Biosensor Based on Titanium Electrode Modified with Prussian Blue Layer and Immobilized Glucose Oxidase
    Valiuniene, A.
    Virbickas, P.
    Rekertaite, A.
    Ramanavicius, A.
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2017, 164 (14) : B781 - B784
  • [32] An Amperometric Glucose Biosensor Composed of Prussian Blue, Nafion, and Glucose Oxidase Studied by Flow Injection Analysis
    Drew, Steven M.
    Belzer, Tristan
    JOURNAL OF CHEMICAL EDUCATION, 2023, 100 (02) : 760 - 766
  • [33] Amperometric tyrosinase biosensor based on a sol-gel-derived titanium oxide-copolymer composite matrix for detection of phenolic compounds
    Chen, X
    Cheng, GJ
    Dong, SJ
    ANALYST, 2001, 126 (10) : 1728 - 1732
  • [34] Electroactivity of redox probes encapsulated within sol-gel-derived silicate films
    Collinson, MM
    Rausch, CG
    Voigt, A
    LANGMUIR, 1997, 13 (26) : 7245 - 7251
  • [35] Application of amperometric sol-gel biosensor to flow injection determination of glucose
    Couto, CMCM
    Araújo, AN
    Montenegro, MCBSM
    Rohwedder, J
    Raimundo, I
    Pasquini, C
    TALANTA, 2002, 56 (06) : 997 - 1003
  • [36] Sol-gel derived iridium composite glucose biosensor
    Tian, FM
    Zhu, GY
    SENSORS AND ACTUATORS B-CHEMICAL, 2002, 86 (2-3): : 266 - 270
  • [37] A HIGH-SENSITIVE GLUCOSE AMPEROMETRIC BIOSENSOR BASED ON PRUSSIAN-BLUE MODIFIED ELECTRODES
    KARYAKIN, AA
    GITELMACHER, OV
    KARYAKINA, EE
    ANALYTICAL LETTERS, 1994, 27 (15) : 2861 - 2869
  • [38] A Highly Sensitive Amperometric Galactose Biosensor Based on Graphene-doped Sol-gel-derived Titania-Nafion Composite Films
    Lee, Sumin
    Jeong, Daeho
    Lee, Sangjung
    Nam, Sungju
    Lee, Won-Yong
    ELECTROANALYSIS, 2022, 34 (04) : 629 - 639
  • [39] Amperometric Tyrosinase Biosensor Based on Carbon Nanotube-Doped Sol-Gel-Derived Zinc Oxide-Nafion Composite Films
    Lee, Joong Min
    Xu, Guang-Ri
    Kim, Byung Kun
    Choi, Han Nim
    Lee, Won-Yong
    ELECTROANALYSIS, 2011, 23 (04) : 962 - 970
  • [40] Incorporation of glucose oxidase into Langmuir-Blodgett films based on Prussian blue applied to amperometric glucose biosensor
    Ohnuki, Hitoshi
    Saiki, Takafumi
    Kusakari, Akira
    Endo, Hideaki
    Ichihara, Masaki
    Izumi, Mitsuru
    LANGMUIR, 2007, 23 (08) : 4675 - 4681