Development of a chemiluminometric immunosensor array for on-site monitoring of genetically modified organisms

被引:10
作者
Jang, Hye-Jee [1 ]
Cho, Il-Hoon [2 ]
Kim, Hee-Soo [2 ]
Jeon, Jin-Woo [2 ]
Hwang, Se-Young [3 ]
Paek, Se-Hwan [1 ,2 ,3 ]
机构
[1] Korea Univ, Grad Sch Life Sci & Biotechnol, Seoul 136701, South Korea
[2] Korea Univ, Program Biomicrosyst Technol, Seoul 136701, South Korea
[3] Korea Univ, Dept Biotechnol, Jochiwon 339800, Choongnam, South Korea
关键词
Genetically modified organisms; Marker proteins; Sandwich-type immunoassys; Chemiluminometric signal; Photodiode array; MODIFIED CROPS; MAIZE; FOODS; PCR; PROTEIN; IMMOBILIZATION; SILANIZATION; REGULATIONS; SURFACE; PLANTS;
D O I
10.1016/j.snb.2011.01.016
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Genetically modified organisms (GMOs) have been mainly developed for mass production of agricultural plants; however, there are concerns that transgenic crops might cause side effects on ecosystems and human beings. Therefore, to quantitatively trace the genetically modified products, we constructed a chemiluminometric immunosensor array for the detection of recombinant marker proteins expressed in GMOs, i.e., 5-enolpyruvylshikimate-3-phosphate synthase (EPSPS), neomycin phosphotransferase II (NPT II), and phophinothricin acethyltransferase (PAT). Monoclonal and polyclonal antibodies specific to each marker were raised, and the specificities and immunoreactivities to the respective markers were characterized. The capture antibodies were immobilized on predetermined regions of a glass slide where the sandwich-type immunoassays were carried out. Photodiodes were located on the bottom of the slide in an aligned arrangement to the immobilized antibody sites such that the light signals resulting from the immunoassays could be detected in situ. Under optimal conditions, the immunosensors were able to detect 1% GMO marked with EPSPS, which was the minimum content over the total content, and 3% GMOs labeled with NPT lot PAT. The sensor array developed in this study would be useful for measuring a particular GMO in a specimen containing unidentified species. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:598 / 605
页数:8
相关论文
共 34 条
[1]   Detection of genetically modified organisms in foods [J].
Ahmed, FE .
TRENDS IN BIOTECHNOLOGY, 2002, 20 (05) :215-223
[2]   Comparison of simplex and duplex real-time PCR for the quantification of GMO in maize and soybean [J].
Alary, R ;
Serin, A ;
Maury, D ;
Ben Jouira, H ;
Sirven, JP ;
Gautier, MF ;
Joudrier, P .
FOOD CONTROL, 2002, 13 (4-5) :235-244
[3]  
ARNE HJ, 2009, BIOTECHNOL ADV, V27, P1071
[4]   Determination of food authenticity by enzyme-linked immunosorbent assay (ELISA) [J].
Asensio, Luis ;
Gonzalez, Isabel ;
Garcia, Teresa ;
Martin, Rosario .
FOOD CONTROL, 2008, 19 (01) :1-8
[5]   Immobilization of antibodies through the surface regions having the highest density in lysine groups on finally inert support surfaces [J].
Batalla, Pilar ;
Mateo, Cesar ;
Grazu, Valeria ;
Fernandez-Lafuente, Roberto ;
Guisan, Jose M. .
PROCESS BIOCHEMISTRY, 2009, 44 (03) :365-368
[6]   Production of a polyclonal antibody raised against recombinant flounder p53 protein [J].
Cachot, J ;
Galgani, F ;
Vincent, F .
COMPARATIVE BIOCHEMISTRY AND PHYSIOLOGY C-PHARMACOLOGY TOXICOLOGY & ENDOCRINOLOGY, 1998, 120 (03) :351-356
[7]   Unintended effects and their detection in genetically modified crops [J].
Cellini, F ;
Chesson, A ;
Colquhoun, I ;
Constable, A ;
Davies, HV ;
Engel, KH ;
Gatehouse, AMR ;
Kärenlampi, S ;
Kok, EJ ;
Leguay, JJ ;
Lehesranta, S ;
Noteborn, HPJM ;
Pedersen, J ;
Smith, M .
FOOD AND CHEMICAL TOXICOLOGY, 2004, 42 (07) :1089-1125
[8]   A risk-based classification scheme for genetically modified foods 1: Conceptual development [J].
Chao, Eunice ;
Krewski, Daniel .
REGULATORY TOXICOLOGY AND PHARMACOLOGY, 2008, 52 (03) :208-222
[9]   Characterization for Binding Complex Formation with Site-Directly Immobilized Antibodies Enhancing Detection Capability of Cardiac Troponin I [J].
Cho, Il-Hoon ;
Seo, Sung-Min ;
Jeon, Jin-Woo ;
Paek, Se-Hwan .
JOURNAL OF BIOMEDICINE AND BIOTECHNOLOGY, 2009,
[10]   Comparison of chemical cleaning methods of glass in preparation for silanization [J].
Cras, JJ ;
Rowe-Taitt, CA ;
Nivens, DA ;
Ligler, FS .
BIOSENSORS & BIOELECTRONICS, 1999, 14 (8-9) :683-688