Exact and efficient cone-beam reconstruction algorithm for a short-scan circle combined with various lines

被引:7
作者
Dennerlein, F [1 ]
Katsevich, A [1 ]
Lauritsch, G [1 ]
Hornegger, J [1 ]
机构
[1] Siemens Med Solut, D-91301 Frochheim, Germany
来源
MEDICAL IMAGING 2005: IMAGE PROCESSING, PT 1-3 | 2005年 / 5747卷
关键词
image reconstruction; computed tomography; cone-beam; theoretically exact; filtered backprojection algorithm; C-arm imaging; circle and line; data completeness; geometric calibration;
D O I
10.1117/12.595186
中图分类号
TB8 [摄影技术];
学科分类号
0804 ;
摘要
X-ray 3D rotational angiography based on C-arm systems has become a versatile and established tomographic imaging modality for high contrast objects in interventional environment. Improvements in data acquisition, e.g. by use of flat panel detectors, will enable C-arm systems to resolve even low-contrast details. However, further progress will be limited by the incompleteness of data acquisition on the conventional short-scan circular source trajectories. Cone artifacts, which result from that incompleteness, significantly degrade image quality by severe smearing and shading. To assure data completeness a combination of a partial circle with one or several line segments is investigated. A new and efficient reconstruction algorithm is deduced from a general inversion formula based on 3D Radon theory. The method is theoretically exact, possesses shift-invariant filtered backprojection (FBP) structure, and solves the long object problem. The algorithm is flexible in dealing with various circle and line configurations. The reconstruction method requires nothing more than the theoretically minimum length of scan trajectory. It consists of a conventional short-scan circle and a line segment approximately twice as long as the height of the region-of-interest. Geometrical deviations from the ideal source trajectory are considered in the implementation in order to handle data of real C-arm systems. Reconstruction results show excellent image quality free of cone artifacts. The proposed scan trajectory and reconstruction algorithm assure excellent image quality and allow low-contrast tomographic imaging with C-arm based cone-beam systems. The method can be implemented without any hardware modifications on systems commercially available today.
引用
收藏
页码:388 / 399
页数:12
相关论文
共 50 条
  • [41] Noise Reduction Using a Theoretically-Exact Algorithm for Helical Cone-Beam Tomography
    Venkataraman, Rajesh
    Noo, Frederic
    Kudo, Hiroyuki
    [J]. 2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 1674 - 1678
  • [42] Exact image reconstruction with triple-source saddle-curve cone-beam scanning
    Lu, Yang
    Zhao, Jun
    Wang, Ge
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (10) : 2971 - 2991
  • [43] Investigation of an Efficient Short-scan C-arm Reconstruction Method with Radon-based Redundancy Handling
    Dennerlein, Frank
    Kunze, Holger
    [J]. MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [44] Reconstruction from Truncated Projections in Cone-beam CT using an Efficient 1D Filtering
    Xia, Yan
    Maier, Andreas
    Hofmann, Hannes G.
    Dennerlein, Frank
    Mueller, Kerstin
    Hornegger, Joachim
    [J]. MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
  • [45] Quasi-exact filtered backprojection algorithm for long-object problem in helical cone-beam tomography
    Kudo, H
    Noo, F
    Defrise, M
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (09) : 902 - 921
  • [46] Evaluation of the OSC-TV iterative reconstruction algorithm for cone-beam optical CT
    Matenine, Dmitri
    Mascolo-Fortin, Julia
    Goussard, Yves
    Despres, Philippe
    [J]. MEDICAL PHYSICS, 2015, 42 (11) : 6376 - 6386
  • [47] Development of a cone angle weighted three-dimensional image reconstruction algorithm to reduce cone-beam artefacts
    Gomi, T.
    Koshida, K.
    Miyati, T.
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2006, 35 (06) : 398 - 406
  • [48] Exact (spiral plus circles) scan region-of-interest cone beam reconstruction via backprojection
    Tam, KC
    Lauritsch, G
    Sourbelle, K
    Sauer, F
    Ladendorf, B
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (05) : 376 - 383
  • [49] Exact 3D cone-beam reconstruction from two short-scans using a C-arm imaging system
    Ramamurthi, K
    Strobel, N
    Prince, JL
    [J]. COMPUTATIONAL IMAGING III, 2005, 5674 : 87 - 98
  • [50] An improved half-covered helical cone-beam CT reconstruction algorithm based on localized reconstruction filter
    Guo, Jiqiang
    Zeng, Li
    Zou, Xiaobing
    [J]. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2011, 19 (03) : 293 - 312