摘要
X-ray 3D rotational angiography based on C-arm systems has become a versatile and established tomographic imaging modality for high contrast objects in interventional environment. Improvements in data acquisition, e.g. by use of flat panel detectors, will enable C-arm systems to resolve even low-contrast details. However, further progress will be limited by the incompleteness of data acquisition on the conventional short-scan circular source trajectories. Cone artifacts, which result from that incompleteness, significantly degrade image quality by severe smearing and shading. To assure data completeness a combination of a partial circle with one or several line segments is investigated. A new and efficient reconstruction algorithm is deduced from a general inversion formula based on 3D Radon theory. The method is theoretically exact, possesses shift-invariant filtered backprojection (FBP) structure, and solves the long object problem. The algorithm is flexible in dealing with various circle and line configurations. The reconstruction method requires nothing more than the theoretically minimum length of scan trajectory. It consists of a conventional short-scan circle and a line segment approximately twice as long as the height of the region-of-interest. Geometrical deviations from the ideal source trajectory are considered in the implementation in order to handle data of real C-arm systems. Reconstruction results show excellent image quality free of cone artifacts. The proposed scan trajectory and reconstruction algorithm assure excellent image quality and allow low-contrast tomographic imaging with C-arm based cone-beam systems. The method can be implemented without any hardware modifications on systems commercially available today.
引用
收藏
页码:388 / 399
页数:12
相关论文
共 50 条
  • [21] Fast parallel image reconstruction for cone-beam FDK algorithm
    Zhang, Shunli
    Geng, Guohua
    Zhao, Jian
    CONCURRENCY AND COMPUTATION-PRACTICE & EXPERIENCE, 2019, 31 (10)
  • [22] A CONE-BEAM SPECT RECONSTRUCTION ALGORITHM WITH A DISPLACED CENTER OF ROTATION
    LI, JY
    JASZCZAK, RJ
    WANG, HL
    GULLBERG, GT
    GREER, KL
    COLEMAN, RE
    MEDICAL PHYSICS, 1994, 21 (01) : 145 - 152
  • [23] An accelerated RAMLA reconstruction algorithm for X-ray cone-beam CT
    Zhao, Xing
    Hu, Jing-jing
    Yang, Tao
    Wang, Feng
    INSIGHT, 2013, 55 (05) : 237 - 242
  • [24] A new weighting scheme for arc based circle cone-beam CT reconstruction
    Wang, Wei
    Xia, Xiang-Gen
    He, Chuanjiang
    Ren, Zemin
    Lu, Jian
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2022, 30 (01) : 145 - 163
  • [25] Three-dimensional weighting reconstruction algorithm for circular cone-beam CT under large scan angles
    Yang, Ya-Fei
    Zhang, Ding-Hua
    Huang, Kui-Dong
    Yang, Fu-Qiang
    Gao, Zong-Zhao
    NUCLEAR SCIENCE AND TECHNIQUES, 2017, 28 (08)
  • [26] A general exact reconstruction for cone-beam CT via backprojection-filtration
    Ye, YB
    Zhao, SY
    Yu, HY
    Wang, G
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2005, 24 (09) : 1190 - 1198
  • [27] Determination of the Exact Reconstruction Region in the Cone-Beam Composite-Circling Mode
    Ye, Lena
    Yu, Hengyong
    Wang, Ge
    DEVELOPMENTS IN X-RAY TOMOGRAPHY VI, 2008, 7078
  • [28] Determination of exact reconstruction regions in composite-circling cone-beam tomography
    Ye, Lena
    Yu, Hengyong
    Wang, Ge
    MEDICAL PHYSICS, 2009, 36 (08) : 3448 - 3454
  • [29] A computational-efficient cone beam CT reconstruction algorithm using circle-and-line orbit
    Lin, WT
    MEDICAL IMAGING 1999: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 1999, 3659 : 933 - 943
  • [30] A half-scan error reduction based algorithm for cone-beam CT
    Zeng, Kai
    Chen, Zhiqiang
    Zhang, Li
    Wang, Ge
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2004, 12 (02) : 73 - 82