Comparison of biventricular ejection fractions using cadmium-zinc-telluride SPECT and planar equilibrium radionuclide angiography

被引:17
|
作者
Chen, Yi-Chieh [1 ,2 ]
Ko, Chi-Lun [3 ]
Yen, Rouh-Fang [1 ,2 ]
Lo, Mei-Fang [1 ,2 ]
Huang, Yih-Hwen [1 ,2 ,4 ]
Hsu, Pei-Ying [3 ]
Wu, Yen-Wen [1 ,2 ,5 ,6 ,7 ]
Cheng, Mei-Fang [1 ,2 ,8 ]
机构
[1] Natl Taiwan Univ Hosp, Dept Nucl Med, 7 Chung Shan South Rd, Taipei, Taiwan
[2] Natl Taiwan Univ, Coll Med, 7 Chung Shan South Rd, Taipei 10764, Taiwan
[3] Natl Taiwan Univ Hosp, Yun Lin Branch, Dept Nucl Med, Touliu, Yunlin, Taiwan
[4] Natl Taiwan Univ, Dept Elect Engn, Taipei 10764, Taiwan
[5] Far Eastern Mem Hosp, Dept Nucl Med, New Taipei, Taiwan
[6] Far Eastern Mem Hosp, Div Cardiol, Cardiovasc Med Ctr, 21,Sec 2,Nanya S Rd, New Taipei, Taiwan
[7] Natl Yang Ming Univ, Sch Med, Taipei 112, Taiwan
[8] Natl Taiwan Univ, Inst Occupat Med & Ind Hyg, Taipei 10764, Taiwan
关键词
Cadmium-zinc-telluride camera; gated blood-pool SPECT; planar equilibrium radionuclide angiography; ventricular ejection fractions; BLOOD-POOL SPECT; CONGESTIVE-HEART-FAILURE; AUTOMATIC QUANTIFICATION; VENTRICULAR FUNCTION; IMAGE QUALITY; VOLUMES; CAMERA; PERFORMANCE; VALIDATION; 8-FRAME;
D O I
10.1007/s12350-015-0367-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We compared biventricular ejection fractions (EFs) from gated blood-pool single-photon emission computed tomography (SPECT) using a cadmium-zinc-telluride camera (CZT-SPECT) with planar equilibrium radionuclide angiography (ERNA) using a NaI gamma camera (NaI-planar). We also evaluated whether imaging time can be reduced without compromising image quality using the CZT camera. Forty-eight patients underwent NaI-planar and CZT-SPECT on the same day. CZT-SPECT datasets were re-projected at an LAO orientation similar to ERNA acquisition, forming CZT-repro planar datasets. The resulting biventricular volumetric measurements and EFs were compared. LVEF calculated from CZT-SPECT and CZT-repro correlated better with NaI-planar (r = 0.93 and 0.99, respectively) than RVEF (r = 0.76 and 0.82, respectively). Excellent intra-class correlation and low bias in intra-observer comparisons were observed for the biventricular EFs derived from three datasets. A wider limit of agreement in CZT-SPECT-derived LVEFs, lower correlation and significant bias for NaI-planar, and CZT-repro-derived RVEFs was found in the inter-observer analyses. Nonetheless, the imaging time can be reduced to 4 minutes without increasing variability in EFs using the CZT camera (P = NS). LVEFs calculated from CZT-SPECT and CZT-repro correlated well with NaI-planar. CZT camera may reduce imaging time while preserving image quality in the assessment of biventricular EFs.
引用
收藏
页码:348 / 361
页数:14
相关论文
共 34 条
  • [21] First comparison of performances between the new whole-body cadmium-zinc-telluride SPECT-CT camera and a dedicated cardiac CZT camera for myocardial perfusion imaging: Analysis of phantom and patients
    Morelle, Maxime
    Bellevre, Dimitri
    Hossein-Foucher, Claude
    Manrique, Alain
    Bailliez, Alban
    JOURNAL OF NUCLEAR CARDIOLOGY, 2020, 27 (04) : 1261 - 1269
  • [22] Comparison of software programs for the assessment of left ventricular ejection fraction using 99mTc-tetrofosmin-gated SPECT/CT: correlation with equilibrium radionuclide ventriculography in the Indian population
    Ballal, Sanjana
    Patel, Chetan D.
    Singla, Suhas
    Sharma, Punit
    Narang, Rajiv
    Sharma, Gautam
    Malhotra, Arun
    NUCLEAR MEDICINE COMMUNICATIONS, 2012, 33 (11) : 1160 - 1168
  • [23] Gated SPECT myocardial perfusion imaging with cadmium-zinc-telluride detectors allows real-time assessment of dobutamine-stress-induced wall motion abnormalities
    Nkoulou, Rene
    Wolfrum, Mathias
    Pazhenkottil, Aju P.
    Fiechter, Michael
    Buechel, Ronny R.
    Gaemperli, Oliver
    Kaufmann, Philipp A.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2019, 26 (05) : 1734 - 1742
  • [24] Quantitative high-efficiency cadmium-zinc-telluride SPECT with dedicated parallel-hole collimation system in obese patients: Results of a multi-center study
    Nakazato, Ryo
    Slomka, Piotr J.
    Fish, Mathews
    Schwartz, Ronald G.
    Hayes, Sean W.
    Thomson, Louise E. J.
    Friedman, John D.
    Lemley, Mark, Jr.
    Mackin, Maria L.
    Peterson, Benjamin
    Schwartz, Arielle M.
    Doran, Jesse A.
    Germano, Guido
    Berman, Daniel S.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2015, 22 (02) : 266 - 278
  • [25] Comparative Performances of Dipyridamole and Regadenoson to Detect Myocardial Ischemia using Cardiac Cadmium-Zinc-Telluride Single-Photon Emission Computerized Tomography
    Ben Bouallegue, Faycal
    Nganoa, Catherine
    Vigne, Jonathan
    Agostini, Denis
    Manrique, Alain
    JOURNAL OF CLINICAL IMAGING SCIENCE, 2018, 8
  • [26] Diagnostic accuracy of cadmium-zinc-telluride-based myocardial perfusion SPECT: impact of attenuation correction using a co-registered external computed tomography
    Caobelli, Federico
    Akin, Muharrem
    Thackeray, James T.
    Brunkhorst, Thomas
    Widder, Julian
    Berding, Georg
    Burchert, Ina
    Bauersachs, Johann
    Bengel, Frank M.
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2016, 17 (09) : 1036 - 1043
  • [27] Determination of the Heart-to-Mediastinum Ratio of 123I-MIBG Uptake Using Dual-Isotope (123I-MIBG/99mTc-Tetrofosmin) Multipinhole Cadmium-Zinc-Telluride SPECT in Patients with Heart Failure
    Blaire, Tanguy
    Bailliez, Alban
    Ben Bouallegue, Faycal
    Bellevre, Dimitri
    Agostini, Denis
    Manrique, Alain
    JOURNAL OF NUCLEAR MEDICINE, 2018, 59 (02) : 251 - 258
  • [28] Comparison of conventional and cadmium-zinc-telluride single-photon emission computed tomography for analysis of thallium-201 myocardial perfusion imaging: an exploratory study in normal databases for different ethnicities
    Ishihara, Masaru
    Onoguchi, Masahisa
    Taniguchi, Yasuyo
    Shibutani, Takayuki
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2017, 33 (12) : 2057 - 2066
  • [29] Verification of optimal conditions for the scattering correction of 123I-FP-CIT SPECT on a single-photon emission tomography system with a two-detector whole-body cadmium-zinc-telluride semiconductor detector
    Izawa, Daisuke
    Ito, Toshimune
    Sanada, Hiroki
    Oku, Takuma
    Nakamoto, Ayaka
    Hiraki, Hitoshi
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2023, 16 (04) : 569 - 577
  • [30] Absolute Myocardial Blood Flow and Flow Reserve Assessed by Gated SPECT with Cadmium Zinc Telluride Detectors Using 99mTc-Tetrofosmin: Head-to-Head Comparison with 13N-Ammonia PET
    Nkoulou, Rene
    Fuchs, Tobias A.
    Pazhenkottil, Aju P.
    Kuest, Silke M.
    Ghadri, Jelena R.
    Stehli, Julia
    Fiechter, Michael
    Herzog, Bernhard A.
    Gaemperli, Oliver
    Buechel, Ronny R.
    Kaufmann, Philipp A.
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57 (12) : 1887 - 1892