Measurement of intracellular vitamin C levels in human lymphocytes by reverse phase high perfon-nance liquid chromatography (HPLC)

被引:41
作者
Emadi-Konjin, P
Verjee, Z
Levin, AV
Adeli, K
机构
[1] Hosp Sick Children, Dept Paediat Lab Med, Toronto, ON M5G 1X8, Canada
[2] Hosp Sick Children, Dept Paediat, Toronto, ON M5G 1X8, Canada
[3] Hosp Sick Children, Dept Ophthalmol, Toronto, ON M5G 1X8, Canada
关键词
ascorbic acid; vitamin C; intracellular vitamin C; lymphocyte vitamin C; high perforniance liquid chromatography (HPLC);
D O I
10.1016/j.clinbiochem.2005.01.018
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives: Vitamin C plays an active role in many important metabolic processes, such as collagen formation and the prevention of bleeding. Although overt scurvy is now rare, there is evidence that subclinical vitamin C deficiency is still quite common. Serum and plasma vitamin C measurements do not correlate well with tissue levels while lymphocyte vitamin C levels provide the most accurate assessment of the true status of vitamin C stores and are not affected acutely by circadian rhythm or dietary changes. We report a specific and reproducible reverse phase high performance liquid chromatographic method (HPLC) for the quantification of vitamin C in lymphocytes. Methods: Reverse phase HPLC with a UV detection system was used. National Committee for Clinical Laboratory Standards (NCCLS) guidelines were followed for evaluation. Sample stability testing for lymphocyte vitamin C was performed for a period of 24 h at room temperature and 4 degrees C. Lymphocyte vitamin C levels were measured in 51 children. Results: Lymphocyte vitamin C measurement with HPLC revealed very good analytical sensitivity with a 1.42 mu wg/10(8) lymphocyte lower limit of detection on repeated testing. An external standard curve was used for quantification, which showed a linear range of 1.25-100 mu g/10(8) lymphocyte with a correlation coefficient of 0.989. Precision studies showed an inter-assay repeatability coefficient of variance (CV) between 0.25-9.98% and a within-assay coefficient of variance between 1.2-12.49%. The inter-assay CV for a period of 20 days was less than 10% for concentrations equal to or less than 1.42 mu g/10(8) lymphocytes and less than 5.5% for concentrations between 5100 mu g/10(8) lymphocytes. Vitamin C was most stable at 4 degrees C, with a 0.31% decrease after 3 h and 2.35% after 4 h. At room temperature, vitamin C loss was more significant, with losses of 8.44% and 15.6% at 3 and 4 h, respectively, at a concentration of 29.9 mu g/10(8) lymphocytes. Conclusions: The proposed HPLC method offers a reliable and reproducible technique for the quantification of intracellular vitamin C. Lymphocyte samples can be rapidly prepared and represent a more homogeneous tissue sample source for intracellular vitamin C measurement as compared to serum. To ensure stability, lymphocyte lysates should be prepared and stored at or below -20 degrees C within 2 h of blood collection. (c) 2005 The Canadian Society of Clinical Chemists. All rights reserved.
引用
收藏
页码:450 / 456
页数:7
相关论文
共 18 条
[1]  
[Anonymous], PRESENT KNOWLEDGE NU
[2]  
BATES CJ, 1994, INT J VITAM NUTR RES, V64, P283
[3]  
Bode AM, 1999, METHOD ENZYMOL, V299, P77
[4]  
Burtis CA., 1999, TIETZ TEXBOOK CLIN C
[5]   Plasma ascorbic acid: measurement, stability and clinical utility revisited [J].
Chung, WY ;
Chung, JKO ;
Szeto, YT ;
Tomlinson, B ;
Benzie, IFF .
CLINICAL BIOCHEMISTRY, 2001, 34 (08) :623-627
[6]  
*COMM BIOCH NOM IU, 1965, BIOCHIM BIOPHYS ACTA, V107, P1
[7]   Vitamin C status of an outpatient population [J].
Johnston, CS ;
Thompson, LL .
JOURNAL OF THE AMERICAN COLLEGE OF NUTRITION, 1998, 17 (04) :366-370
[8]   Relation between plasma ascorbic acid and mortality in men and women in EPIC-Norfolk prospective study: a prospective population study [J].
Khaw, KT ;
Bingham, S ;
Welch, A ;
Luben, R ;
Wareham, N ;
Oakes, S ;
Day, N .
LANCET, 2001, 357 (9257) :657-663
[9]   Criteria and recommendations for vitamin C intake [J].
Levine, M ;
Rumsey, SC ;
Daruwala, R ;
Park, JB ;
Wang, YH .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1999, 281 (15) :1415-1423
[10]   Determination of ascorbic acid and dehydroascorbic acid in biological samples by high-performance liquid chromatography using subtraction methods: Reliable reduction with tris[2-carboxyethyl] phosphine hydrochloride [J].
Lykkesfeldt, J .
ANALYTICAL BIOCHEMISTRY, 2000, 282 (01) :89-93