Fabricated aptamer-based electrochemical "signal-off" sensor of ochratoxin A

被引:200
作者
Kuang, Hua [1 ]
Chen, Wei [1 ]
Xu, Dinghua [1 ]
Xu, Liguang [1 ]
Zhu, Yingyue [1 ]
Liu, Liqiang [1 ]
Chu, Huaqin [1 ]
Peng, Chifang [1 ]
Xu, Chuanlai [1 ]
Zhu, Shuifang [1 ]
机构
[1] Jiangnan Univ, State Key Lab Food Sci & Technol, Sch Food Sci & Technol, Wuxi 214122, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
Ultrasensitive; Toxin detection; Electrochemical detection; Aptamer; LINKED-IMMUNOSORBENT-ASSAY; IN-VITRO SELECTION; GOLD NANOPARTICLES; ULTRASENSITIVE DETECTION; SMALL MOLECULES; CHROMATOGRAPHY; AMPLIFICATION; BIOSENSOR; SEQUENCE; PLATFORM;
D O I
10.1016/j.bios.2010.06.058
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
An ultrasensitive and rapid electrochemical platform for the specific detection of ochratoxin A (OTA) was developed. In this method, three single-stranded DNA molecules, including the aptamer, were immobilized on the surface of an electrode. Binding of the OTA target analyte to the aptamer changed the redox current of methylene blue (MB), which was used as the electrochemical probe, in a manner that was dependent on OTA concentration. With signal enhancement from gold nanoparticle-functionalized DNA, the sensitivity of this method for OTA was as low as 30 pg/mL, and the effective sensing range was from 0.1 to 20 ng/mL To investigate the sensing process, the conformational switch of the aptamer was studied by circular dichroism (CD), which confirmed the recognition of the aptamer by the target OTA. Given its sensitivity and rapid detection, we believe this approach has the potential to be a main technology for the detection of toxins in the field of food safety, and in other areas. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:710 / 716
页数:7
相关论文
共 48 条
[1]   Evaluation of methods used to determine ochratoxin a in coffee beans [J].
Ahmed, N. E. ;
Farag, M. M. ;
Soliman, K. M. ;
Abdel-Samed, A. K. M. ;
Naguib, Kh. M. .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2007, 55 (23) :9576-9580
[2]   A novel electrochemical detection method for aptamer biosensors [J].
Bang, GS ;
Cho, S ;
Kim, BG .
BIOSENSORS & BIOELECTRONICS, 2005, 21 (06) :863-870
[3]   Sensitive ELISA test for determination of ochratoxin A [J].
Barna-Vetro, I ;
Solti, L ;
Teren, J ;
Gyongyosi, A ;
Szabo, E ;
Wolfling, A .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1996, 44 (12) :4071-4074
[4]   DNA enzymes [J].
Breaker, RR .
NATURE BIOTECHNOLOGY, 1997, 15 (05) :427-431
[5]   PLASMA OCHRATOXIN A LEVELS IN 3 SWEDISH POPULATIONS SURVEYED USING AN ION-PAIR HPLC TECHNIQUE [J].
BREITHOLTZ, A ;
OLSEN, M ;
DAHLBACK, A ;
HULT, K .
FOOD ADDITIVES AND CONTAMINANTS, 1991, 8 (02) :183-192
[6]   Rational design and performance testing of aptamer-based electrochemical biosensors for adenosine [J].
Chakraborty, Banani ;
Jiang, Zhifeng ;
Li, Yunchao ;
Yu, Hua-Zhong .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2009, 635 (02) :75-82
[7]   Automated and ultrasensitive detection of methyl-3-quinoxaline-2-carboxylic acid by using gold nanoparticles probes SIA-rt-PCR [J].
Chen, Wei ;
Jiang, Yuan ;
Ji, Baoqing ;
Zhu, Changqin ;
Liu, Liqiang ;
Peng, Chifang ;
Jin, M. Kim ;
Qiao, Ruirui ;
Jin, Zhengyu ;
Wang, Libing ;
Zhu, Shuifang ;
Xu, Chuanlai .
BIOSENSORS & BIOELECTRONICS, 2009, 24 (09) :2858-2863
[8]   Ultrasensitive immunoassay of 7-aminoclonazepam in human urine based on CdTe nanoparticle bioconjugations by fabricated microfluidic chip [J].
Chen, Wei ;
Peng, Chifang ;
Jin, Zhengyue ;
Qiao, Ruirui ;
Wang, Wuyang ;
Zhu, Shuifang ;
Wang, Libing ;
Jing, Qinhui ;
Xu, Chuanlai .
BIOSENSORS & BIOELECTRONICS, 2009, 24 (07) :2051-2056
[9]   DEVELOPMENT OF A QUANTITATIVE AND SENSITIVE ENZYME-LINKED-IMMUNOSORBENT-ASSAY FOR OCHRATOXIN-A USING ANTIBODIES FROM THE YOLK OF THE LAYING HEN [J].
CLARKE, JR ;
MARQUARDT, RR ;
OOSTERVELD, A ;
FROHLICH, AA ;
MADRID, FJ ;
DAWOOD, M .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1993, 41 (10) :1784-1789
[10]   Automated RNA selection [J].
Cox, JC ;
Rudolph, P ;
Ellington, AD .
BIOTECHNOLOGY PROGRESS, 1998, 14 (06) :845-850