Towards the conception of an amperometric sensor of L-tyrosine based on Hemin/PAMAM/MWCNT modified glassy carbon electrode

被引:80
|
作者
Ma, Qiang [1 ]
Ai, Shiyun [1 ]
Yin, Huanshun [1 ]
Chen, Quanpeng [2 ]
Tang, Tiantian [2 ]
机构
[1] Shandong Agr Univ, Coll Chem & Mat Sci, Tai An 271018, Shandong, Peoples R China
[2] Shandong Agr Univ, Coll Resources & Environm, Tai An 271018, Shandong, Peoples R China
基金
中国国家自然科学基金;
关键词
Amperometric sensor; Hemin; L-Tyrosine; Poly (amidoamine); Multi-walled carbon nanotube; ELECTROCHEMICAL-BEHAVIOR; HYDROGEN-PEROXIDE; PROTOPORPHYRIN-IX; DENDRITIC MACROMOLECULES; STARBURST DENDRIMERS; GOLD ELECTRODE; HEMIN; NANOTUBES; FILMS; NITRITE;
D O I
10.1016/j.electacta.2010.06.003
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A novel amperometric sensor was fabricated based on the immobilization of hemin onto the poly (amidoamine)/multi-walled carbon nanotube (PAMAM/MWCNT) nanocomposite film modified glassy carbon electrode (GCE). Electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV) and ultraviolet visible (UV-vis) adsorption spectroscopy were used to investigate the possible state and electrochemical activity of the immobilized hemin. In the Hemin/PAMAM/MWCNT nanocomposite film, MWCNT layer possessed excellent inherent conductivity to enhance the electron transfer rate, while the layer of PAMAM greatly enlarged the surface average concentration of hemin (Gamma) on the modified electrode. Therefore, the nanocomposite film showed enhanced electrocatalytical activity towards the oxidation of L-tyrosine. The kinetic parameters of the modified electrode were investigated. In pH 7.0 phosphate buffer solution (PBS), the sensor exhibits a wide linear range from 0.1 mu M to 28.8 mu M L-tyrosine with a detection limit of 0.01 mu M and a high sensitivity of 0.31 mu A mu M-1 cm(-2). In addition, the response time of the L-tyrosine sensor is less than 5s. The excellent performance of the sensor is largely attributed to the electro-generated high reactive oxoiron (IV) porphyrin (O = Fe-IV-P) which effectively catalyzed the oxidation of L-tyrosine. A mechanism was herein proposed for the catalytic oxidation of L-tyrosine by oxoiron (IV) porphyrin complexes. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:6687 / 6694
页数:8
相关论文
共 50 条
  • [1] Electrochemical L-Tyrosine Sensor Based on a Glassy Carbon Electrode Modified with Exfoliated Graphene
    Varodi, Codruta
    Pogacean, Florina
    Coro, Maria
    Ciori, Alexandra
    Pruneanu, Stela
    SENSORS, 2022, 22 (10)
  • [2] Amperometric determination of L-tyrosine by an enzymeless sensor based on a carbon ceramic electrode modified with copper oxide nanoparticles
    Razmi, Habib
    Nasiri, Hojjat
    Mohammad-Rezaei, Rahim
    MICROCHIMICA ACTA, 2011, 173 (1-2) : 59 - 64
  • [3] Amperometric determination of L-tyrosine by an enzymeless sensor based on a carbon ceramic electrode modified with copper oxide nanoparticles
    Habib Razmi
    Hojjat Nasiri
    Rahim Mohammad-Rezaei
    Microchimica Acta, 2011, 173 : 59 - 64
  • [4] An Amperometric Hydrogen Peroxide Sensor Based on Hollow Carbon Spheres/Pt NPs Modified Glassy Carbon Electrode
    Zhang, Yuanyuan
    Duan, Hongliang
    Yuan, Wang
    Li, Yunlong
    Zhang, Yueqi
    Yang, Xiaoling
    Liao, Xiaoling
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2022, 17 (12):
  • [5] Amperometric sensor based on tricobalt tetroxide nanoparticles-graphene nanocomposite film modified glassy carbon electrode for determination of tyrosine
    Jiang, Lin
    Gu, Shuqing
    Ding, Yaping
    Ye, Daixin
    Zhang, Zhen
    Zhang, Fenfen
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2013, 107 : 146 - 151
  • [6] Non-enzymatic hydrogen peroxide amperometric sensor based on a glassy carbon electrode modified with an MWCNT/polyaniline composite film and platinum nanoparticles
    Zhong, Huaan
    Yuan, Ruo
    Chai, Yaqin
    Zhang, Yu
    Wang, Chengyan
    Jia, Feng
    MICROCHIMICA ACTA, 2012, 176 (3-4) : 389 - 395
  • [7] Amperometric sensor based on multi-walled carbon nanotube and poly (Bromocresol purple) modified carbon paste electrode for the sensitive determination of L-tyrosine in food and biological samples
    Shrestha, Siddharth
    Mascarenhas, Ronald J.
    D'Souza, Ozma J.
    Satpati, Ashis K.
    Mekhalif, Zineb
    Dhason, A.
    Martis, Praveen
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2016, 778 : 32 - 40
  • [8] Electrochemical behavior and determination of L-tyrosine at single-walled carbon nanotubes modified glassy carbon electrode
    Yu, Xiaozhi
    Mai, Zhibin
    Xiao, Yun
    Zou, Xiaoyong
    ELECTROANALYSIS, 2008, 20 (11) : 1246 - 1251
  • [9] A hemin-based molecularly imprinted polymer (MIP) grafted onto a glassy carbon electrode as a selective sensor for 4-aminophenol amperometric
    Martins Neto, Jose de Ribamar
    Rodrigues Santos, Wilney de Jesus
    Rodrigues Lima, Phabyanno
    Carvalho Neiva Tanaka, Sonia Maria
    Tanaka, Auro Atsushi
    Kubota, Lauro Tatsuo
    SENSORS AND ACTUATORS B-CHEMICAL, 2011, 152 (02): : 220 - 225
  • [10] Electrochemical behavior and voltammetric determination of L-tryptophan and L-tyrosine using a glassy carbon electrode modified with single-walled carbon nanohorns
    Zhu, Shuyun
    Zhang, Jiao
    Zhao, Xian-en
    Wang, Hua
    Xu, Guobao
    You, Jinmao
    MICROCHIMICA ACTA, 2014, 181 (3-4) : 445 - 451