Performance comparison of ejectors in ejector-based refrigeration cycles with R1234yf, R1234ze(E) and R134a

被引:5
作者
Li, Shizhen [1 ]
Liu, Yingxin [1 ]
Liu, Yanjun [1 ,2 ]
Zhang, Jingzhi [3 ]
机构
[1] Shandong Univ, Inst Marine Sci & Technol, Qingdao 266237, Peoples R China
[2] Shandong Univ, Sch Mech Engn, Jinan 250061, Peoples R China
[3] Shandong Univ, Sch Energy & Power Engn, Jinan 266237, Peoples R China
基金
中国国家自然科学基金; 国家重点研发计划;
关键词
Single-phase ejector; Numerical analysis; Entrainment ratio; Shocking position; Hypothetical throat; Expansion angle; Heat transfer; COMPUTATIONAL FLUID-DYNAMICS; DROP-IN REPLACEMENT; LOW-GRADE HEAT; VAPOR COMPRESSION; STEAM EJECTOR; THERMODYNAMIC ANALYSIS; CFD; FLOW; OPTIMIZATION; SIMULATION;
D O I
10.1007/s11356-021-14626-7
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
To look for new refrigerants replacing R134a, environmentally friendly refrigerants R1234yf and R1234ze(E) were chosen as the alternatives in an ejector refrigeration system. The tested system contained a single-phase ejector, and numerical analysis regarding the performance of the ejector was done by CFD. The entrainment ratio, static pressure and Mach number were chosen as indicators revealing the ejector performance. Changes of the indicators of ejector utilizing a given refrigerant under varying operating temperature conditions were analysed. With the increasing condenser temperature, the shocking position moved upstream until it combined with the first series of oblique shocks. With the increasing generator temperature, the entrainment ratio increased firstly and decreased subsequently. With the increasing evaporator temperature, the primary-fluid jet expansion weakened. Comparisons of the indicators of ejector utilizing three working fluids (R134a, R1234yf and R1234ze(E)) under a given operating temperature condition were also made. The results showed that R1234yf had a greater entrainment ratio than R134a and R1234ze(E). But the shocking position of R1234yf was also closer to the upstream than the other two refrigerants, which caused the smaller critical mode region. Compared with the entrainment ratio close to 1.4 times, the critical temperature difference of only 3 degrees C could not weaken the advantages of R1234yf. Besides, heat transfer inside the ejector was considered and not much different trends with the three working fluids were found. Therefore, R1234yf could be the better candidate for R134a in the ejector refrigeration system.
引用
收藏
页码:57166 / 57182
页数:17
相关论文
共 50 条
  • [21] Exergoeconomic performance comparison of R1234yf as a drop-in replacement for R134a in a domestic refrigerator
    Rangel-Hernandez, V. H.
    Belman-Flores, J. M.
    Rodriguez-Valderrama, D. A.
    Pardo-Cely, D.
    Rodriguez-Munoz, A. P.
    Ramirez-Minguela, J. J.
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2019, 100 : 113 - 123
  • [22] Retrofitting an air-conditioning device to utilize R1234yf and R1234ze(E) refrigerants as alternatives to R22
    Oruc, Vedat
    Devecioglu, Atilla G.
    [J]. JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2018, 40 (04)
  • [23] Performance characteristics of R1234yf ejector-expansion refrigeration cycle
    Li, Huashan
    Cao, Fei
    Bu, Xianbiao
    Wang, Lingbao
    Wang, Xianlong
    [J]. APPLIED ENERGY, 2014, 121 : 96 - 103
  • [24] Effect of flame retardant R134a on the flammability characteristics of R1234yf
    Zhai, Rui
    Tan, Siwei
    Zhuang, Yuan
    Wang, Zhandong
    Ye, Bin
    Shi, Yongjie
    [J]. ENERGY, 2024, 313
  • [25] Investigation of a novel ejector expansion refrigeration system using the working fluid R134a and its potential substitute R1234yf
    Boumaraf, Latra
    Haberschill, Philippe
    Lallemand, Andre
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2014, 45 : 148 - 159
  • [26] Performance of low GWP R1234yf/R134a mixture as a replacement for R134a in automotive air conditioning systems
    Meng, Zhaofeng
    Zhang, Hua
    Lei, Mingjing
    Qin, Yanbin
    Qiu, Jinyou
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2018, 116 : 362 - 370
  • [27] Comparison of transient response of an evaporator model for water refrigeration system working with R1234yf as a drop-in replacement for R134a
    Garcia, Juan
    Ali, Thiago
    Duarte, Willian Moreira
    Khosravi, Ali
    Machado, Luiz
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2018, 91 : 211 - 222
  • [28] Flow boiling heat transfer of binary mixtures of R1234yf/R32 and R1234ze (E)/R32 in a horizontal minichannel
    Jige, Daisuke
    Inoue, Norihiro
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2024, 233
  • [29] Flow pattern transition during condensation of R134a and R1234ze(E) in microchannel arrays
    Wang, Ji
    Li, Jun Ming
    Hwang, Yunho
    [J]. APPLIED THERMAL ENGINEERING, 2017, 115 : 244 - 255
  • [30] Experimental Testing of a Water-to-Water Heat Pump with and without IHX by Using Refrigerants R1234yf and R1234ze(E)
    Bosnjakovic, Mladen
    Santa, Robert
    Katinic, Marko
    [J]. SUSTAINABILITY, 2023, 15 (11)