Performance comparison of ejectors in ejector-based refrigeration cycles with R1234yf, R1234ze(E) and R134a

被引:5
|
作者
Li, Shizhen [1 ]
Liu, Yingxin [1 ]
Liu, Yanjun [1 ,2 ]
Zhang, Jingzhi [3 ]
机构
[1] Shandong Univ, Inst Marine Sci & Technol, Qingdao 266237, Peoples R China
[2] Shandong Univ, Sch Mech Engn, Jinan 250061, Peoples R China
[3] Shandong Univ, Sch Energy & Power Engn, Jinan 266237, Peoples R China
基金
国家重点研发计划; 中国国家自然科学基金;
关键词
Single-phase ejector; Numerical analysis; Entrainment ratio; Shocking position; Hypothetical throat; Expansion angle; Heat transfer; COMPUTATIONAL FLUID-DYNAMICS; DROP-IN REPLACEMENT; LOW-GRADE HEAT; VAPOR COMPRESSION; STEAM EJECTOR; THERMODYNAMIC ANALYSIS; CFD; FLOW; OPTIMIZATION; SIMULATION;
D O I
10.1007/s11356-021-14626-7
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
To look for new refrigerants replacing R134a, environmentally friendly refrigerants R1234yf and R1234ze(E) were chosen as the alternatives in an ejector refrigeration system. The tested system contained a single-phase ejector, and numerical analysis regarding the performance of the ejector was done by CFD. The entrainment ratio, static pressure and Mach number were chosen as indicators revealing the ejector performance. Changes of the indicators of ejector utilizing a given refrigerant under varying operating temperature conditions were analysed. With the increasing condenser temperature, the shocking position moved upstream until it combined with the first series of oblique shocks. With the increasing generator temperature, the entrainment ratio increased firstly and decreased subsequently. With the increasing evaporator temperature, the primary-fluid jet expansion weakened. Comparisons of the indicators of ejector utilizing three working fluids (R134a, R1234yf and R1234ze(E)) under a given operating temperature condition were also made. The results showed that R1234yf had a greater entrainment ratio than R134a and R1234ze(E). But the shocking position of R1234yf was also closer to the upstream than the other two refrigerants, which caused the smaller critical mode region. Compared with the entrainment ratio close to 1.4 times, the critical temperature difference of only 3 degrees C could not weaken the advantages of R1234yf. Besides, heat transfer inside the ejector was considered and not much different trends with the three working fluids were found. Therefore, R1234yf could be the better candidate for R134a in the ejector refrigeration system.
引用
收藏
页码:57166 / 57182
页数:17
相关论文
共 50 条
  • [1] Performance comparison of ejectors in ejector-based refrigeration cycles with R1234yf, R1234ze(E) and R134a
    Shizhen Li
    Yingxin Liu
    Yanjun Liu
    Jingzhi Zhang
    Environmental Science and Pollution Research, 2021, 28 : 57166 - 57182
  • [2] Performance Analysis of Refrigerants R1234yf, R1234ze and R134a in Ejector-Based Refrigeration Cycle
    Yadav, Ajay Kumar
    Neeraj
    INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2018, 26 (03)
  • [3] Analysis the characteristics of R1234yf, R1234ze, R134a on reefer container
    Ding, Defeng
    Zhu, Zhenxiang
    Chen, Wu
    Liu, Shijie
    Zheng, Chaoyu
    2019 5TH INTERNATIONAL CONFERENCE ON ADVANCES IN ENERGY RESOURCES AND ENVIRONMENT ENGINEERING (ICAESEE 2019), 2020, 446
  • [4] Performance Evaluation of Centrifugal Refrigeration Compressor Using R1234yf and R1234ze(E) as Drop-In Replacements for R134a Refrigerant
    Yi, Kexin
    Zhao, Yuanyang
    Liu, Guangbin
    Yang, Qichao
    Yu, Guoxin
    Li, Liansheng
    ENERGIES, 2022, 15 (07)
  • [5] R1234yf and R1234ze as alternatives to R134a in Organic Rankine Cycles for low temperature heat sources
    Moles, Francisco
    Navarro-Esbri, Joaquin
    Peris, Bernardo
    Mota-Babiloni, Adrian
    Mateu-Royo, Carlos
    PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON APPLIED ENERGY, 2017, 142 : 1192 - 1198
  • [6] Optimization Design and Performance Evaluation of R1234yf Ejectors for Ejector-Based Refrigeration Systems
    Yu, Meihong
    Wang, Chen
    Wang, Lei
    Zhao, Hongxia
    ENTROPY, 2022, 24 (11)
  • [7] Performance evaluation of VCR system with pure and various blends of R134a, R1234yf, and R1234ze (E) refrigerants
    Kuwar, Yogendra Vasantrao
    HEAT TRANSFER, 2024, 53 (06) : 2879 - 2904
  • [8] HORIZONTAL CONVECTIVE BOILING OF R134A, R1234YF/R134A, AND R1234ZE(E) WITHIN A MICRO-FIN TUBE
    Kedzierski, M. A.
    Park, K. -J.
    JOURNAL OF ENHANCED HEAT TRANSFER, 2013, 20 (04) : 333 - 346
  • [9] Exergy analysis of R1234yf and R1234ze as R134a replacements in a two evaporator vapour compression refrigeration system
    Yataganbaba, Alptug
    Kilicarslan, Ali
    Kurtbas, Irfan
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2015, 60 : 26 - 37
  • [10] Liquid Viscosity Measurements for the Binary and Ternary Refrigerant Mixtures of R134a, R1234ze(E), and R1234yf
    Liang, Ximei
    Sun, Qingyu
    Meng, Xianyang
    Wu, Jiangtao
    JOURNAL OF CHEMICAL AND ENGINEERING DATA, 2022, 67 (08): : 1872 - 1881