In this presentation BANG (R) polymer-gel dosimetry using magnetic resonance imaging (MRI) is applied to densely ionizing radiation such as carbon ion beams. BANG (R) polymer-gels were irradiated with monoenergetic C-12 ions at an energy of 205 MeVu(-1). The irradiation of the gels with doses up to 100 Gy were performed at the radiotherapy facility of the GSI, Darmstadt, Germany. For comparison with sparsely ionizing radiation data were obtained for 6 MV photon radiation, too. It was the object to examine the saturation effect for densely ionizing radiation that occurs at high values of linear energy transfer (LET). Up to now the dose response is unknown for mixed radiation fields of primary carbon ions. Therefore, to facilitate such conversions of measured MR signals into dose model calculations are proposed. This model relies only on heavy ion track structure and the experimentally determined photon response.
引用
收藏
页码:S99 / S101
页数:3
相关论文
共 10 条
[1]   EFFECTS OF DIFFUSION ON FREE PRECESSION IN NUCLEAR MAGNETIC RESONANCE EXPERIMENTS [J].
CARR, HY ;
PURCELL, EM .
PHYSICAL REVIEW, 1954, 94 (03) :630-638
[2]   Efficiency of thermoluminescent detectors to heavy charged particles [J].
Geiss, OB ;
Kramer, M ;
Kraft, G .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1998, 142 (04) :592-598
[3]   MEASUREMENT OF RADIATION-DOSE DISTRIBUTIONS BY NUCLEAR MAGNETIC-RESONANCE (NMR) IMAGING [J].
GORE, JC ;
KANG, YS ;
SCHULZ, RJ .
PHYSICS IN MEDICINE AND BIOLOGY, 1984, 29 (10) :1189-1197
[4]   MAGNETIC SCANNING SYSTEM FOR HEAVY-ION THERAPY [J].
HABERER, T ;
BECHER, W ;
SCHARDT, D ;
KRAFT, G .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 330 (1-2) :296-305
[5]   Calculations of heavy-ion track structure [J].
Kramer, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1995, 105 (1-4) :14-20
[6]   NMR RELAXATION ENHANCEMENT IN GELS POLYMERIZED AND CROSS-LINKED BY IONIZING-RADIATION - A NEW APPROACH TO 3D DOSIMETRY BY MRI [J].
MARYANSKI, MJ ;
GORE, JC ;
KENNAN, RP ;
SCHULZ, RJ .
MAGNETIC RESONANCE IMAGING, 1993, 11 (02) :253-258
[7]   MODIFIED SPIN-ECHO METHOD FOR MEASURING NUCLEAR RELAXATION TIMES [J].
MEIBOOM, S ;
GILL, D .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1958, 29 (08) :688-691
[8]   Three-dimensional BANG™ gel dosimetry in conformal carbon ion radiotherapy [J].
Ramm, U ;
Weber, U ;
Bock, M ;
Krämer, M ;
Bankamp, A ;
Damrau, M ;
Thilmann, C ;
Bottcher, HD ;
Schad, LR ;
Kraft, G .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (09) :N95-N102
[9]  
SCHOLZ M, 1994, RADIAT PROT DOSIM, V52, P29
[10]   Experimental investigations of the response of films to heavy-ion irradiation [J].
Spielberger, B ;
Scholz, M ;
Krämer, M ;
Kraft, G .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (11) :2889-2897