摘要
We present the use of an entropy focus criterion to enable automatic focussing of motion corrupted magnetic resonance images. Our technique can determine unknown patient motion or use knowledge of motion from other measures as a starting estimate. The motion estimate is used to compensate the acquired data and is iteratively refined using the image entropy. Our entropy criterion focuses the whole, image principally by favoring the removal of motion induced ghosts and blurring from otherwise dark regions of the image. Using only the image data, and no special hardware or pulse sequences, we demonstrate correction for arbitrary rigid-body translational motion in the imaging plane and for a single rotation. Extension to 3D and more general motion should be possible.
引用
收藏
页码:341 / 354
页数:14
相关论文
共 50 条
  • [1] AUTOMATIC DETECTION OF MOTION ARTIFACTS IN MR IMAGES USING CNNS
    Meding, Kristof
    Loktyushin, Alexander
    Hirsch, Michael
    2017 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH AND SIGNAL PROCESSING (ICASSP), 2017, : 811 - 815
  • [2] Autofocusing of clinical shoulder MR images for correction of motion artifacts
    Manduca, A
    McGee, KP
    Welch, EB
    Felmlee, JP
    Ehman, RL
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI'98, 1998, 1496 : 598 - 605
  • [3] Automatic motion correction of clinical shoulder MR images
    Manduca, A
    McGee, KP
    Welch, EB
    Felmlee, JP
    Ehman, RL
    MEDICAL IMAGING 1999: IMAGE PROCESSING, PTS 1 AND 2, 1999, 3661 : 367 - 374
  • [4] Automatic correction of motion artifacts in magnetic resonance images using an entropy focus criterion
    Atkinson, D
    Hill, DLG
    Stoyle, PNR
    Summers, PE
    Keevil, SF
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1997, 16 (06) : 903 - 910
  • [5] Correction of Artifacts in Diffusion-Weighted MR Images
    Marcon, Petr
    Bartusek, Karel
    Korinek, Radim
    Dokoupil, Zdenek
    2011 34TH INTERNATIONAL CONFERENCE ON TELECOMMUNICATIONS AND SIGNAL PROCESSING (TSP), 2011, : 391 - 397
  • [6] UNSUPERVISED ADVERSARIAL CORRECTION OF RIGID MR MOTION ARTIFACTS
    Armanious, Karim
    Tanwar, Aastha
    Abdulatif, Sherif
    Kuestner, Thomas
    Gatidis, Sergios
    Bin Yang
    2020 IEEE 17TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI 2020), 2020, : 1494 - 1498
  • [7] An Improved Algorithm of Motion Artifacts Correction for MRI
    Wu Chunli
    Zhai Jiangnan
    Nie Rong
    2013 25TH CHINESE CONTROL AND DECISION CONFERENCE (CCDC), 2013, : 5148 - 5152
  • [8] Fast automatic correction of motion artifacts in shoulder MRI
    Manduca, A
    McGee, KP
    Welch, EB
    Felmlee, JP
    Ehman, RL
    MEDICAL IMAGING: 2001: IMAGE PROCESSING, PTS 1-3, 2001, 4322 : 853 - 859
  • [9] Automatic motion correction for breast MR imaging
    Zuo, CS
    Jiang, AP
    Buff, BL
    Mahon, TG
    Wong, TZ
    RADIOLOGY, 1996, 198 (03) : 903 - 906
  • [10] Feature Preserving Autofocus Algorithm for Phase Error Correction of SAR Images
    Lee, Haemin
    Jung, Chang-Sik
    Kim, Ki-Wan
    SENSORS, 2021, 21 (07)