Edwards SAPIEN Transcatheter Pulmonary Valve Implantation Results From a French Registry

被引:28
作者
Plessis, Julien [1 ]
Hascoet, Sebastien [2 ,3 ]
Baruteau, Alban [1 ,4 ,5 ]
Godart, Francois [6 ]
Le Gloan, Laurianne [1 ]
Fresse, Karine Warin [1 ]
Tahhan, Nabil [2 ]
Riou, Jean-Yves [2 ]
Guyomarch, Beatrice [1 ]
Petit, Jerome [2 ]
Guerin, Patrice [1 ]
机构
[1] CHU Nantes, Inst Thorax, Federat Cardiopathies Congenitales, Serv Cardiol, Nantes, France
[2] Univ Paris Sud, Ctr Reference Malformat Cardiaques Congenitales C, Marie Lannelongue, Pole Chirurg Cardiopathies Congenitales, Paris, France
[3] Univ Paris Sud, Univ Paris Saclay, Hop Marie Lannelongue, Inserm UMR S999, Le Kremlin Bicetre, France
[4] Univ Nantes, Inst Thorax, CNRS, INSERM, Nantes, France
[5] Guys & St Thomass NHS Fdn Trust, Evelina London Childrens Hosp, London, England
[6] Univ Lille Nord France, Dept Pediat & Congenital Heart Dis, Lille, France
关键词
congenital heart disease; Edwards SAPIEN pulmonic valve; percutaneous pulmonary valve implantation; pulmonary regurgitation; pulmonary stenosis; CORONARY-ARTERY COMPRESSION; VENTRICULAR OUTFLOW TRACTS; MELODY VALVE; INFECTIVE ENDOCARDITIS; PERCUTANEOUS IMPLANTATION; HEART-VALVE; REPLACEMENT; MULTICENTER; OUTCOMES; RISK;
D O I
10.1016/j.jcin.2018.05.050
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES The aim of this study was to describe and analyze data from patients treated in France with the Edwards SAPIEN transcatheter heart valve (Edwards Lifesciences LLC, Irvine, California) in the pulmonary position. BACKGROUND The Edwards SAPIEN valve has recently been introduced for percutaneous pulmonary valve implantation (PPVI). METHODS From April 2011 to May 2017, 71 patients undergoing PPVI were consecutively included. RESULTS The median age at PPVI was 26.8 years (range 12.8 to 70.1 years). Primary underlying diagnoses were conotruncal malformations (common arterial trunk, tetralogy of fallot and variants; n 45), Ross procedure (n = 18), and other diagnoses (n = 8). PPVI indication was pure stenosis in 33.8% of patients, pure regurgitation in 28.1%, and mixed lesions in 38.1%. PPVI was successfully implemented in 68 patients (95.8%). Pre-stenting of the right ventricular outflow tract was performed in 70 patients (98.6%). Early major complications occurred in 4 subjects (5.6%), including 1 death, 1 coronary compression, and 2 pulmonary valve embolizations. Three of the 4 major complications occurred in the first 15 operated patients. No significant regurgitation was recorded after the procedure. Transpulmonary gradient was significantly reduced from 34.5 to 10.5 mm Hg (p < 0.0001). No patient died during a 1-month follow-up period. At 1-year follow-up, the death rate was 2.9%, and 3 patients had undergone surgical reintervention (44%). CONCLUSIONS Early results with the Edwards SAPIEN valve in the pulmonary position demonstrate an ongoing high rate of procedural success. (C) 2018 by the American College of Cardiology Foundation.
引用
收藏
页码:1909 / 1916
页数:8
相关论文
共 37 条
[1]  
[Anonymous], 2013, CURR PEDIATR REP, DOI DOI 10.1007/S40124-013-0013-9]
[2]   Left Anterior Descending Coronary Artery Occlusion During Transcatheter Pulmonary Valve Implantation Successful Rescue Percutaneous Revascularization [J].
Baruteau, Alban-Elouen ;
Petit, Jerome ;
Brenot, Philippe ;
Riou, Jean-Yves ;
Angel, Claude-Yves .
JACC-CARDIOVASCULAR INTERVENTIONS, 2014, 7 (09) :1073-1074
[3]   Reoperative homograft right ventricular outflow tract reconstruction [J].
Bielefeld, MR ;
Bishop, DA ;
Campbell, DN ;
Mitchell, MB ;
Grover, FL ;
Clarke, DR .
ANNALS OF THORACIC SURGERY, 2001, 71 (02) :482-487
[4]   Percutaneous replacement of pulmonary valve in a right-ventricle to pulmonary-artery prosthetic conduit with valve dysfunction [J].
Bonhoeffer, P ;
Boudjemline, Y ;
Saliba, Z ;
Merckx, J ;
Aggoun, Y ;
Bonnet, D ;
Acar, P ;
Le Bidois, J ;
Sidi, D ;
Kachaner, J .
LANCET, 2000, 356 (9239) :1403-1405
[5]   Transcatheter Pulmonary Valve Implantation Using the Edwards SAPIEN™ Transcatheter Heart Valve [J].
Boone, Robert H. ;
Webb, John G. ;
Horlick, Eric ;
Benson, Lee ;
Cao, Qi-Ling ;
Nadeem, N. ;
Kiess, Maria ;
Hijazi, Ziyad M. .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2010, 75 (02) :286-294
[6]   Off-label use of percutaneous pulmonary valved stents in the right ventricular outflow tract: Time to rewrite the label? [J].
Boshoff, Derize E. ;
Cools, Bjorn L. M. ;
Heying, Ruth ;
Troost, Els ;
Kefer, Joelle ;
Budts, Werner ;
Gewillig, Marc .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 81 (06) :987-995
[7]   Predictors and outcomes of right ventricular outflow tract conduit rupture during percutaneous pulmonary valve implantation: a multicentre study [J].
Boudjemline, Younes ;
Malekzadeh-Milani, Sophie ;
Patel, Mehul ;
Thambo, Jean -Benoit ;
Bonnet, Damien ;
Iserin, Laurence ;
Fraisse, Alain .
EUROINTERVENTION, 2016, 11 (09) :1053-1062
[8]   Outcomes and safety of transcatheter pulmonary valve replacement in patients with large patched right ventricular outflow tracts [J].
Boudjemline, Younes ;
Brugada, Georgia ;
Van-Aerschot, Isabelle ;
Patel, Mehul ;
Basquin, Adeline ;
Bonnet, Caroline ;
Legendre, Antoine ;
Bonnet, Damien ;
Iserin, Laurence .
ARCHIVES OF CARDIOVASCULAR DISEASES, 2012, 105 (8-9) :404-413
[9]   Melody transcatheter pulmonary valve implantation. Results from the registry of the Italian society of pediatric cardiology [J].
Butera, Gianfranco ;
Milanesi, Ornella ;
Spadoni, Isabella ;
Piazza, Luciane ;
Donti, Andrea ;
Ricci, Christian ;
Agnoletti, Gabriella ;
Pangrazi, Alberta ;
Chessa, Massimo ;
Carminati, Mario .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 81 (02) :310-316
[10]   Clinical and Hemodynamic Outcomes up to 7 Years After Transcatheter Pulmonary Valve Replacement in the US Melody Valve Investigational Device Exemption Trial [J].
Cheatham, John P. ;
Hellenbrand, William E. ;
Zahn, Evan M. ;
Jones, Thomas K. ;
Berman, Darren P. ;
Vincent, Julie A. ;
McElhinney, Doff B. .
CIRCULATION, 2015, 131 (22) :1960-+