Photoplethysmography Motion Artifacts Removal Based on Signal-Noise Interaction Modeling Utilizing Envelope Filtering and Time-Delay Neural Network

被引:33
作者
Xu, Ke [1 ]
Jiang, Xinyu [1 ]
Chen, Wei [2 ,3 ,4 ]
机构
[1] Fudan Univ, Sch Informat Sci & Technol, Ctr Intelligent Med Elect, Shanghai 200433, Peoples R China
[2] Fudan Univ, Ctr Intelligent Med Elect, Shanghai 200433, Peoples R China
[3] Fudan Univ, Sch Informat Sci & Technol, Shanghai 200433, Peoples R China
[4] Fudan Univ, Human Phenome Inst, Shanghai 200433, Peoples R China
关键词
Pliotoplethysmography (PPG); motion artifacts (MA); time-delay neural network (TDNN); envelope filtering; heart rate estimation; physiological feature extraction; BLOOD-PRESSURE ESTIMATION; RESPIRATORY RATE; REDUCTION; CANCELLATION; ALGORITHM;
D O I
10.1109/JSEN.2019.2960370
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Physiological features extraction from Motion Artifacts (MA) corrupted Photoplethysmography (PPG) signals are of great difficulty due to the non-linear interaction between clean PPG and noise. To accurately extract features such as heart rate, blood pressure, and Oxygen Saturation in Blood, a robust PPG de-noising and waveform recovering method is required. However, traditional adaptive filtering or signal decomposition methods fail to achieve this goal. In this paper, a Signal-Noise Interaction modeling based algorithm for motion artifacts removal (SniMA) under strenuous physical exercise utilizing Envelope Filtering (EF) and Time-Delay Neural Network (TDNN) is proposed. Envelope Filtering normalizes raw data and eliminates imbalance training problem for neural networks, while TDNN is a hidden-state included method aiming at modeling PPG signal-noise interaction. An accelerometer as well as a gyroscope functions as the noise reference. Results comparing 8 performance indexes extracted from 4 types of waveform related features (heart rate, waveform correlation, pulse width, and pulse area) on an open access dataset we built show SniMAs effectiveness for PPG MA removal. The proposed algorithm provides a significant improvement in PPG waveform recovery and PPG feature estimation accuracy. This is the first time that a TDNN has been introduced for PPG de-noising. This study also indicates the potential of other hidden-state involved signal-noise interaction modeling methods for PPG de-noising.
引用
收藏
页码:3732 / 3744
页数:13
相关论文
共 59 条
[31]   Relationship Between Measurement Site and Motion Artifacts in Wearable Reflected Photoplethysmography [J].
Maeda, Yuka ;
Sekine, Masaki ;
Tamura, Toshiyo .
JOURNAL OF MEDICAL SYSTEMS, 2011, 35 (05) :969-976
[32]   Heart Rate Tracking using Wrist-Type Photoplethysmographic (PPG) Signals during Physical Exercise with Simultaneous Accelerometry [J].
Mashhadi, Mahdi Boloursaz ;
Asadi, Ehsan ;
Eskandari, Mohsen ;
Kiani, Shahrzad ;
Marvasti, Farokh .
IEEE SIGNAL PROCESSING LETTERS, 2016, 23 (02) :227-231
[33]   Wavelet-based motion artifact removal for functional near-infrared spectroscopy [J].
Molavi, Behnam ;
Dumont, Guy A. .
PHYSIOLOGICAL MEASUREMENT, 2012, 33 (02) :259-270
[34]   Pulse transit time by r-wave-gated infrared photoplethysmography: Review of the literature and personal experience [J].
Naschitz J.E. ;
Bezobchuk S. ;
Mussafia-Priselac R. ;
Sundick S. ;
Dreyfuss D. ;
Khorshidi I. ;
Karidis A. ;
Manor H. ;
Nagar M. ;
Peck E.R. ;
Peck S. ;
Storch S. ;
Rosner I. ;
Gaitini L. .
Journal of Clinical Monitoring and Computing, 2004, 18 (5-6) :333-342
[35]   Monitoring of respiratory rate in postoperative care using a new photoplethysmographic technique [J].
Nilsson, L ;
Johansson, A ;
Kalman, S .
JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2000, 16 (04) :309-315
[36]  
Pang B, 2016, BIOMED CIRC SYST C, P196, DOI 10.1109/BioCAS.2016.7833765
[37]   Motion artifact removal from photoplethysmographic signals by combining temporally constrained independent component analysis and adaptive filter [J].
Peng, Fulai ;
Zhang, Zhengbo ;
Gou, Xiaoming ;
Liu, Hongyun ;
Wang, Weidong .
BIOMEDICAL ENGINEERING ONLINE, 2014, 13
[38]  
Raghuram M., 2012, 2012 Proceedings of IEEE International Symposium on Medical Measurements and Applications (MeMeA 2012), DOI 10.1109/MeMeA.2012.6226643
[39]  
Raghuram M., 2010, 2010 10th International Conference on Information Sciences, Signal Processing and their Applications (ISSPA 2010), P460, DOI 10.1109/ISSPA.2010.5605443
[40]   ICA-Based Improved DTCWT Technique for MA Reduction in PPG Signals With Restored Respiratory Information [J].
Ram, M. Raghu ;
Madhav, K. Venu ;
Krishna, Ette Hari ;
Komalla, Nagarjuna Reddy ;
Sivani, Kosaraju ;
Reddy, K. Ashoka .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2013, 62 (10) :2639-2651