Photoplethysmography Motion Artifacts Removal Based on Signal-Noise Interaction Modeling Utilizing Envelope Filtering and Time-Delay Neural Network

被引:33
作者
Xu, Ke [1 ]
Jiang, Xinyu [1 ]
Chen, Wei [2 ,3 ,4 ]
机构
[1] Fudan Univ, Sch Informat Sci & Technol, Ctr Intelligent Med Elect, Shanghai 200433, Peoples R China
[2] Fudan Univ, Ctr Intelligent Med Elect, Shanghai 200433, Peoples R China
[3] Fudan Univ, Sch Informat Sci & Technol, Shanghai 200433, Peoples R China
[4] Fudan Univ, Human Phenome Inst, Shanghai 200433, Peoples R China
关键词
Pliotoplethysmography (PPG); motion artifacts (MA); time-delay neural network (TDNN); envelope filtering; heart rate estimation; physiological feature extraction; BLOOD-PRESSURE ESTIMATION; RESPIRATORY RATE; REDUCTION; CANCELLATION; ALGORITHM;
D O I
10.1109/JSEN.2019.2960370
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Physiological features extraction from Motion Artifacts (MA) corrupted Photoplethysmography (PPG) signals are of great difficulty due to the non-linear interaction between clean PPG and noise. To accurately extract features such as heart rate, blood pressure, and Oxygen Saturation in Blood, a robust PPG de-noising and waveform recovering method is required. However, traditional adaptive filtering or signal decomposition methods fail to achieve this goal. In this paper, a Signal-Noise Interaction modeling based algorithm for motion artifacts removal (SniMA) under strenuous physical exercise utilizing Envelope Filtering (EF) and Time-Delay Neural Network (TDNN) is proposed. Envelope Filtering normalizes raw data and eliminates imbalance training problem for neural networks, while TDNN is a hidden-state included method aiming at modeling PPG signal-noise interaction. An accelerometer as well as a gyroscope functions as the noise reference. Results comparing 8 performance indexes extracted from 4 types of waveform related features (heart rate, waveform correlation, pulse width, and pulse area) on an open access dataset we built show SniMAs effectiveness for PPG MA removal. The proposed algorithm provides a significant improvement in PPG waveform recovery and PPG feature estimation accuracy. This is the first time that a TDNN has been introduced for PPG de-noising. This study also indicates the potential of other hidden-state involved signal-noise interaction modeling methods for PPG de-noising.
引用
收藏
页码:3732 / 3744
页数:13
相关论文
共 59 条
[1]   Reflectance Photoplethysmography as Noninvasive Monitoring of Tissue Blood Perfusion [J].
Abay, Tomas Ysehak ;
Kyriacou, Panayiotis A. .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2015, 62 (09) :2187-2195
[2]   Effect of Multiscale PCA De-noising in ECG Beat Classification for Diagnosis of Cardiovascular Diseases [J].
Alickovic, Emina ;
Subasi, Abdulhamit .
CIRCUITS SYSTEMS AND SIGNAL PROCESSING, 2015, 34 (02) :513-533
[3]   Photoplethysmography and its application in clinical physiological measurement [J].
Allen, John .
PHYSIOLOGICAL MEASUREMENT, 2007, 28 (03) :R1-R39
[4]  
[Anonymous], 2008, THESIS
[5]  
Asada HH, 2004, P ANN INT IEEE EMBS, V26, P2157
[6]   Non-Invasive Detection of Mechanical Alternans Utilizing Photoplethysmography [J].
Besleaga, Tudor ;
Badiani, Sveeta ;
Lloyd, Guy ;
Toschi, Nicola ;
Canichella, Antonio ;
Demosthenous, Andreas ;
Lambiase, Pier David ;
Orini, Michele .
IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2019, 23 (06) :2409-2416
[7]  
Chan K. W., 2002, Proceedings of IEEE Sensors 2002. First IEEE International Conference on Sensors (Cat. No.02CH37394), P1343, DOI 10.1109/ICSENS.2002.1037314
[8]   A Method for Respiration Rate Detection in Wrist PPG Signal Using Holo-Hilbert Spectrum [J].
Chang, Hsiao-Huang ;
Hsu, Chuan-Chih ;
Chen, Chia-Yuen ;
Lee, Wai-Keung ;
Hsu, Hao-Teng ;
Shyu, Kuo-Kai ;
Yeh, Jia-Rong ;
Lin, Pin-Jun ;
Lee, Po-Lei .
IEEE SENSORS JOURNAL, 2018, 18 (18) :7560-7569
[9]   Breathing Rate Estimation from the Electrocardiogram and Photoplethysmogram: A Review [J].
Charlton, Peter H. ;
Birrenkott, Drew A. ;
Bonnici, Timothy ;
Pimentel, Marco A. F. ;
Johnson, Alistair E. W. ;
Alastruey, Jordi ;
Tarassenko, Lionel ;
Watkinson, Peter J. ;
Beale, Richard ;
Clifton, David A. .
IEEE Reviews in Biomedical Engineering, 2018, 11 :2-20
[10]   A Robust Motion Artifact Detection Algorithm for Accurate Detection of Heart Rates From Photoplethysmographic Signals Using Time-Frequency Spectral Features [J].
Dao, Duy ;
Salehizadeh, S. M. A. ;
Noh, Yeonsik ;
Chong, Jo Woon ;
Cho, Chae Ho ;
McManus, Dave ;
Darling, Chad E. ;
Mendelson, Yitzhak ;
Chon, Ki H. .
IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2017, 21 (05) :1242-1253