Minimally invasive plate osteosynthesis in humerus nonunion after intramedullary nailing

被引:10
作者
Allende, Christian [1 ]
Vanoli, Fernando [1 ]
Gentile, Luciano [1 ]
Gutierrez, Natalia [1 ]
机构
[1] Sanatorio Allende, Inst Allende Cirugia Reconstruct, Hipolito Yrigoyen 384, RA-5000 Cordoba, Argentina
关键词
Humerus diaphyseal nonunion; Failed intramedullary nailing; Minimally invasive plating; SHAFT FRACTURES; MANAGEMENT; FIXATION; FAILURE;
D O I
10.1007/s00264-018-3911-1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
IntroductionThe purpose of this study was to evaluate the results achieved after the use of lateral minimally invasive plate osteosynthesis (MIPO) in oligotrophic humerus nonunions resulting from failed intramedullary nailing (IM).MethodWe evaluated nine patients with humerus nonunion after failed locked intramedullary nailing, all treated using 3.5-mm locked compression plates (LCP) placed through lateral minimally invasive approaches, between 2010 and 2016. Patient's age averaged 39.7years. All nonunions were diaphyseal and oligotrophic. All nonunions had previous surgical treatment with static locked nails (seven antegrade and two retrograde). The IM nails were all well inserted in the humerus (none of them protruded or had rotator cuff lesions associated). Pre-operative Disabilities of the Arm, Shoulder and Hand (DASH) score averaged 25.5 points. Pre-operative Constant's score averaged 80.2. Pre-operative visual analog scale of pain averaged 2.4 points.ResultsFollow-up averaged 17.7months. Time between initial surgery and revision procedure averaged 11.7months. Union was achieved in all cases, after an average of 4.8months. DASH score at last follow-up averaged 5.1 points, and final Constant's score averaged 93.7 points. The analog scale of pain averaged 0.7 points. Time from definitive surgery to work return averaged 3.9months. Long 3.5-mm LCPs were used (plate length averaged 16.9 screw holes). In two cases, a third 4-cm incision at the nonunion site was performed and cancellous autologous iliac crest bone graft was associated.ConclusionIn our series of nine patients, we achieved union and good objective and subjective results, with high patient satisfaction, using a lateral MIPO technique and placing long 3.5-mm LCPs in selected oligotrophic humerus nonunions after failed IM nailing.
引用
收藏
页码:2685 / 2689
页数:5
相关论文
共 50 条
  • [41] Antero-lateral minimally invasive plate osteosynthesis (MIPO) with the radial nerve exploration for extra-articular distal-third diaphyseal fractures of the humerus
    Zhao, Wei
    Qu, Wei
    Fu, Chongyang
    Jiang, Huajun
    Liu, Sida
    Cheng, Chao
    INTERNATIONAL ORTHOPAEDICS, 2017, 41 (09) : 1757 - 1762
  • [42] Repair of Distal Fibula Fractures with Minimally Invasive Intramedullary Nailing in the Elderly
    Bridges, Rayven
    Saulabiu, Angelica
    JOURNAL OF THE AMERICAN PODIATRIC MEDICAL ASSOCIATION, 2023, 113 (04)
  • [43] Exchange nailing versus augmentative plating in the treatment of femoral shaft nonunion after intramedullary nailing: a meta-analysis
    Luo, Hua
    Sue, Yongwei
    Ding, Liang
    Xiao, Haijun
    Wu, Ming
    Xue, Feng
    EFORT OPEN REVIEWS, 2019, 4 (08): : 513 - 518
  • [44] Pneumothorax after minimally invasive plate osteosynthesis for midshaft clavicle fracture A case report
    Kim, Mi Kyeong
    Lee, Hyun-Jung
    You, Ann Hee
    Kang, Hee Yong
    MEDICINE, 2019, 98 (33)
  • [45] Minimally invasive osteosynthesis in stable trochanteric fractures: a comparative study between Gotfried percutaneous compression plate and Gamma 3 intramedullary nail
    Ramon Varela-Egocheaga, Jose
    Iglesias-Colao, R.
    Suarez-Suarez, M. A.
    Fernandez-Villan, M.
    Gonzalez-Sastre, V.
    Murcia-Mazon, A.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2009, 129 (10) : 1401 - 1407
  • [46] Minimally invasive plate osteosynthesis of clavicular midshaft fractures under insertion guide
    Ko, Mun Sik
    Ri, Kwang-Il
    Mun, Tong-Won
    Song, Kwang-Il
    Choe, Kwang-Il
    ULUSAL TRAVMA VE ACIL CERRAHI DERGISI-TURKISH JOURNAL OF TRAUMA & EMERGENCY SURGERY, 2021, 27 (05): : 552 - 557
  • [47] Minimally Invasive Plate Osteosynthesis in Open Pediatric Tibial Fractures
    Ozkul, Emin
    Gem, Mehmet
    Arslan, Huseyin
    Alemdar, Celil
    Azboy, Ibrahim
    Arslan, Seher G.
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2016, 36 (04) : 416 - 422
  • [48] Locked intramedullary nailing of symptomatic metastases in the humerus
    Spencer, S. J.
    Holt, G.
    Clarke, J. V.
    Mohammed, A.
    Leach, W. J.
    Roberts, J. L. B.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2010, 92B (01): : 142 - 145
  • [49] Guidelines for surgical approaches for minimally invasive plate osteosynthesis in cats
    Schmierer, Philipp A.
    Pozzi, Antonio
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2017, 30 (04) : 272 - 278
  • [50] Minimally Invasive Plate Osteosynthesis of Humeral Shaft Fractures: Current State of the Art
    Tetsworth, Kevin
    Hohmann, Erik
    Glatt, Vaida
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2018, 26 (18) : 652 - 661