Volumetry of simulated bone grafts in the edentulous maxilla by computed tomography:: an experimental study

被引:43
作者
Johansson, B [1 ]
Grepe, A [1 ]
Wannfors, K [1 ]
Åberg, P [1 ]
Hirsch, JM [1 ]
机构
[1] Univ Uppsala Hosp, Dept Surg Sci Oral & Maxillofacial Surg, S-75185 Uppsala, Sweden
关键词
tomography; X-ray computed; biometry; dental implants; maxillary sinus;
D O I
10.1038/sj.dmfr.4600600
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To determine the precision of CT for calculating the volume of bone grafts to the maxilla. Methods: Plaster of Paris was used to simulate bone as onlay and inlay grafts to the maxillary alveolus and sinus in a dry skull. Two mm thick axial C-P scans were obtained. The area of the graft on each slice was measured and volumes calculated according to the formula V-graft=Sigma of areas x the thickness of each section, Scans were repeated with the skull at approximately + 5 degrees and - 5 degrees to the horizontal plane and the calculations repeated, The real volume was calculated by the displaced water technique, Precision was estimated as reliability coefficient. Results: The reliability coefficients for the right and left inlay and the onlay grafts were 0.97, 0.6 and 0.96 respectively. Conclusion: Calculations of the volume of both inlay and onlay grafts to the maxilla from axial CT is precise.
引用
收藏
页码:153 / 156
页数:4
相关论文
共 16 条
[1]  
[Anonymous], 1994, JOMI
[2]   QUANTITATIVE THEORY OF HOUNSFIELD UNIT AND ITS APPLICATION TO DUAL ENERGY SCANNING [J].
BROOKS, RA .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1977, 1 (04) :487-493
[3]  
Ekestubbe A, 1993, Dentomaxillofac Radiol, V22, P13
[4]   EFFECTIVE DOSE AND RISK ASSESSMENT FROM COMPUTED-TOMOGRAPHY OF THE MAXILLOFACIAL COMPLEX [J].
FREDERIKSEN, NL ;
BENSON, BW ;
SOKOLOWSKI, TW .
DENTOMAXILLOFACIAL RADIOLOGY, 1995, 24 (01) :55-58
[5]   Computed tomographic evaluation of bone formation after secondary bone grafting of alveolar clefts [J].
Honma, K ;
Kobayashi, T ;
Nakajima, T ;
Hayasi, T .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1999, 57 (10) :1209-1213
[6]   In vitro analysis of the accuracy of subtraction radiography and computed tomography scanning for determination of bone graft volume [J].
Jensen, J ;
Kragskov, J ;
Wenzel, A ;
Sindet-Pedersen, S .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1998, 56 (06) :743-748
[7]   Volumetry of bone grafts by three-dimensional computed tomographic reconstruction: an animal study in the minipig [J].
Jensen, J ;
Kragskov, J ;
Wenzel, A ;
Sindet-Pedersen, S .
DENTOMAXILLOFACIAL RADIOLOGY, 1998, 27 (01) :41-44
[8]  
Johansson B, 1999, INT J ORAL MAX IMPL, V14, P811
[9]   Oral implants in combination with bone grafts - A 3-year retrospective multicenter study using the Branemark implant system [J].
Lekholm, U ;
Wannfors, K ;
Isaksson, S ;
Adielsson, B .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1999, 28 (03) :181-187
[10]   Autogenous onlay bone grafts fixed with screw implants for the treatment of severely resorbed maxillae - Radiographic evaluation of preoperative bone dimensions, postoperative bone loss, and changes in soft-tissue profile [J].
Nystrom, E ;
Ahlqvist, J ;
Kahnberg, KE ;
Rosenquist, JB .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1996, 25 (05) :351-359