Highly Sensitive Determination of Coating Thickness by using the High Filling Factor in an Adiabatically Coupled Terahertz Waveguide

被引:0
|
作者
Theuer, Michael [1 ,2 ]
Beigang, Rene [2 ]
Grischkowsky, Daniel R. [1 ]
机构
[1] Oklahoma State Univ, Stillwater, OK 74078 USA
[2] Fraunhofer Inst Phys Measurement Tech, D-67663 Kaiserslautern, Germany
基金
美国国家科学基金会;
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Terahertz time-domain spectroscopy can be used to detect the thickness of thin dielectric layers by measuring the relative pulse delay of the propagating terahertz pulse. The detection limit was considerably increased by using the high filling factor of a 2-cylinder waveguide sensor. The single-pass delay was increased by a factor of more than 150 for dielectric layers down to 2.5 microns thickness. Using the adiabatic coupling and guiding of the metal cylinders, no further optics were necessary.
引用
收藏
页数:2
相关论文
共 50 条
  • [31] Performance of Avocado Seed Activated Carbon as Adsorbent for Highly Sensitive Determination of Cd Using a Flow Injection System Online Coupled to TS-FF-AAS
    Kudo, Marianne V. F.
    de Oliveira, Leandro L. G.
    Suquila, Fabio A. C.
    de Almeida, Fernanda G.
    Segatelli, Mariana G.
    Lima, Eder C.
    Dias, Silvio L. P.
    Tarley, Cesar R. T.
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2020, 31 (01) : 100 - 108
  • [32] Highly sensitive determination of polybrominated diphenyl ethers in surface water by GC coupled to high-resolution MS according to the EU Water Directive 2008/105/EC
    Barco-Bonilla, Nieves
    Plaza-Bolanos, Patricia
    Valera Tarifa, Noelia Ma
    Romero-Gonzalez, Roberto
    Martinez Vidal, Jose Luis
    Garrido Frenich, Antonia
    JOURNAL OF SEPARATION SCIENCE, 2014, 37 (1-2) : 69 - 76
  • [33] Highly sensitive determination of nitric oxide in biologic samples by a near-infrared BODIPY-based fluorescent probe coupled with high-performance liquid chromatography
    Zhang, Hui-Xian
    Chen, Jian-Bo
    Guo, Xiao-Feng
    Wang, Hong
    Zhang, Hua-Shan
    TALANTA, 2013, 116 : 335 - 342
  • [34] Development of a sensitive method for the determination of acrylamide in coffee using high-performance liquid chromatography coupled to a hybrid quadrupole Orbitrap mass spectrometer
    Pugajeva, Iveta
    Jaunbergs, Janis
    Bartkevics, Vadims
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2015, 32 (02): : 170 - 179
  • [35] Highly Sensitive Determination of 2,4,6-Trinitrotoluene and Related Byproducts Using a Diol Functionalized Column for High Performance Liquid Chromatography
    Gumuscu, Burcu
    Erdogan, Zeynep
    Guler, Mustafa O.
    Tekinay, Turgay
    PLOS ONE, 2014, 9 (06):
  • [36] High-performance liquid chromatographic method for rapid and highly sensitive determination of histidine using postcolumn fluorescence detection with o-phthaldialdehyde
    Tateda, N
    Matsuhisa, K
    Hasebe, K
    Kitajima, N
    Miura, T
    JOURNAL OF CHROMATOGRAPHY B, 1998, 718 (02): : 235 - 241
  • [37] Highly sensitive rapid determination of orotic acid in urine samples using a field-amplified sample stacking approach in capillary electrophoresis coupled with contactless conductivity detection
    Adimcilar, Veselina
    Saygili, Merve Taser
    Cansever, Mehmet Serif
    Oztekin, Nevin
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2024, 238
  • [38] Sensitive determination of nitric oxide in some rat tissues using polymer monolith microextraction coupled to high-performance liquid chromatography with fluorescence detection
    Huang, Ke-Jing
    Zhang, Min
    Xie, Wan-Zhen
    Zhang, Hua-Shan
    Feng, Yu-Qi
    Wang, Hong
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 388 (04) : 939 - 946
  • [39] Sensitive determination of nitric oxide in some rat tissues using polymer monolith microextraction coupled to high-performance liquid chromatography with fluorescence detection
    Ke-Jing Huang
    Min Zhang
    Wan-Zhen Xie
    Hua-Shan Zhang
    Yu-Qi Feng
    Hong Wang
    Analytical and Bioanalytical Chemistry, 2007, 388 : 939 - 946
  • [40] Highly sensitive method for determination of N-nitrosamines using high-performance liquid chromatography with online UV irradiation and luminol chemiluminescence detection
    Kodamatani, Hitoshi
    Yamazaki, Shigeo
    Saito, Keiitsu
    Amponsaa-Karikari, Abena
    Kishikawa, Naoya
    Kuroda, Naotaka
    Tomiyasu, Takashi
    Komatsu, Yu
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (01) : 92 - 98