Development and characterization of an ELISA assay in PDMS microfluidic channels

被引:265
作者
Eteshola, E [1 ]
Leckband, D [1 ]
机构
[1] Univ Illinois, Dept Chem Engn, Urbana, IL 61801 USA
基金
美国国家卫生研究院;
关键词
polydimethylsiloxane (PDMS); microfluidic device; immunoassay; flow-through; sensor;
D O I
10.1016/S0925-4005(00)00640-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This report describes the first preliminary evaluation of a heterogeneous sandwich enzyme-linked immunoassay in a PDMS microfluidic device. The PDMS devices were fabricated using replica molding against a patterned photoresist generated by photolithographic techniques. With this experimental setup, the microfluidic sensor chip was successfully used to quantify a model analyte (sheep IgM) with sensitivity down to 17 nM. The conventional blocking cocktail used in nearly all polystyrene microtiter plate-based ELISA assays failed to block the nonspecific adsorption of the analyte and secondary antibody. This report describes the successful use of surface modification chemistries and a modified blocking cocktail to reduce background due to nonspecific adsorption and to thereby increase the sensitivity of the assay. These protocols can be extended to the detection of a variety of analytes by immunoassay in PDMS microchannels. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:129 / 133
页数:5
相关论文
共 29 条
[21]   ARTIFACTS AND LIMITATIONS OF ENZYME-IMMUNOASSAY [J].
PESCE, AJ ;
MICHAEL, JG .
JOURNAL OF IMMUNOLOGICAL METHODS, 1992, 150 (1-2) :111-119
[22]  
PRICE CP, 1997, PRINCPLES PRACTICE I
[23]   Recent developments in flow injection immunoanalysis [J].
Puchades, R ;
Maquieira, A .
CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 1996, 26 (04) :195-218
[24]  
RASMUSSEN SE, 1988, COMPLEMENTARY IMMUNO, P43
[25]   Identification of unacceptable background caused by non-specific protein adsorption to the plastic surface of 96-well immunoassay plates using a standardized enzyme-linked immunosorbent assay procedure [J].
Rebeski, DE ;
Winger, EM ;
Shin, YK ;
Lelenta, M ;
Robinson, MM ;
Varecka, R ;
Crowther, JR .
JOURNAL OF IMMUNOLOGICAL METHODS, 1999, 226 (1-2) :85-92
[26]  
SPENER F, 1997, FRONTIERS BIOSENSORI, V2
[27]   Flow-through fluorescence immunosensor for atrazine determination [J].
Turiel, E ;
Fernández, P ;
Pérez-Conde, C ;
Gutiérrez, AM ;
Cámara, C .
TALANTA, 1998, 47 (05) :1255-1261
[28]   QUANTITATIVE DIFFERENCES AMONG VARIOUS PROTEINS AS BLOCKING-AGENTS FOR ELISA MICROTITER PLATES [J].
VOGT, RF ;
PHILLIPS, DL ;
HENDERSON, LO ;
WHITFIELD, W ;
SPIERTO, FW .
JOURNAL OF IMMUNOLOGICAL METHODS, 1987, 101 (01) :43-50
[29]   CONTINUOUS-FLOW IMMUNOSENSOR FOR DETECTION OF EXPLOSIVES [J].
WHELAN, JP ;
KUSTERBECK, AW ;
WEMHOFF, GA ;
BREDEHORST, R ;
LIGLER, FS .
ANALYTICAL CHEMISTRY, 1993, 65 (24) :3561-3565