The Motional Stark Effect with Laser-Induced Fluorescence Diagnostic

被引:4
|
作者
Foley, E. L. [1 ]
Levinton, F. M. [1 ]
机构
[1] Nova Photonics Inc, Princeton, NJ 08540 USA
关键词
MAGNETIC-FIELD; PLASMAS; BEAM;
D O I
10.1088/1742-6596/227/1/012007
中图分类号
O59 [应用物理学];
学科分类号
摘要
The motional Stark effect (MSE) diagnostic is the worldwide standard technique for internal magnetic field pitch angle measurements in magnetized plasmas. Traditionally, it is based on using polarimetry to measure the polarization direction of light emitted from a hydrogenic species in a neutral beam. As the beam passes through the magnetized plasma at a high velocity, in its rest frame it perceives a Lorentz electric field. This field causes the H-alpha emission to be split and polarized. A new technique under development adds laser-induced fluorescence (LIF) to a diagnostic neutral beam (DNB) for an MSE measurement that will enable radially resolved magnetic field magnitude as well as pitch angle measurements in even low-field (<1 T) experiments. An MSE-LIF system will be installed on the National Spherical Torus Experiment (NSTX) at the Princeton Plasma Physics Laboratory. It will enable reconstructions of the plasma pressure, q-profile and current as well as, in conjunction with the existing MSE system, measurements of radial electric fields.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Development of the motional Stark effect with laser-induced fluorescence diagnostic
    Foley, EL
    Levinton, FM
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (10): : 3462 - 3464
  • [2] Progress on the motional Stark effect with laser-induced fluorescence diagnostic
    Foley, E. L.
    Levinton, F. M.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2006, 77 (10):
  • [3] Measurements with magnetic field in the National Spherical Torus Experiment using the motional Stark effect with laser induced fluorescence diagnostic
    Foley, E. L.
    Levinton, F. M.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2013, 84 (04):
  • [4] Motional Stark effect diagnostic on TEXTOR
    Jakubowska, K
    De Bock, M
    Jaspers, R
    von Hellermann, M
    Shmaenok, L
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (10): : 3475 - 3477
  • [5] The motional Stark effect diagnostic on NSTX
    Levinton, F. M.
    Yuh, H.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2008, 79 (10):
  • [6] The motional Stark effect diagnostic for ITER
    Foley, E. L.
    Levinton, F. M.
    Uzun-Kaymak, I. U.
    Galante, M. E.
    Zhang, X.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2024, 95 (07):
  • [7] The MAST motional Stark effect diagnostic
    Conway, N. J.
    De Bock, M. F. M.
    Michael, C. A.
    Walsh, M. J.
    Carolan, P. G.
    Hawkes, N. C.
    Rachlew, E.
    McCone, J. F. G.
    Shibaev, S.
    Wearing, G.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2010, 81 (10):
  • [8] Laser-induced fluorescence and Optical/Stark spectroscopy of PtC
    Beaton, SA
    Steimle, TC
    JOURNAL OF CHEMICAL PHYSICS, 1999, 111 (24): : 10876 - 10882
  • [9] Laser-induced fluorescence diagnostic for divertors
    McChesney, J.M.
    Lippmann, S.I.
    Goldstein, W.H.
    Fournier, K.B.
    Review of Scientific Instruments, 1995, 66 (1 pt 2): : 600 - 602
  • [10] LASER-INDUCED FLUORESCENCE AS A PLASMA DIAGNOSTIC
    KOHLER, P
    STERN, RA
    HELVETICA PHYSICA ACTA, 1983, 56 (04): : 934 - 934