Radiolucent 4D Ultrasound Imaging: System Design and Application to Radiotherapy Guidance

被引:22
作者
Schlosser, Jeffrey [1 ]
Hristov, Dimitre [2 ]
机构
[1] SoniTrack Syst Inc, Palo Alto, CA 94306 USA
[2] Stanford Univ, Sch Med, Stanford, CA 94305 USA
基金
美国国家科学基金会;
关键词
CT; image guidance; motion monitoring; multi-modality imaging; radiation therapy; robotics; ultrasound; EXTERNAL-BEAM RADIOTHERAPY; RADIATION-THERAPY; MOTION;
D O I
10.1109/TMI.2016.2559499
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Four-dimensional (4D) ultrasound (US) is an attractive modality for image guidance due to its real-time, non-ionizing, volumetric imaging capability with high soft tissue contrast. However, existing 4D US imaging systems contain large volumes of metal which interfere with diagnostic and therapeutic ionizing radiation in procedures such as CT imaging and radiation therapy. This study aimed to design and characterize a novel 4D Radiolucent Remotely-Actuated UltraSound Scanning (RRUSS) device that overcomes this limitation. In a phantom, we evaluated the imaging performance of the RRUSS device including frame rate, resolution, spatial integrity, and motion tracking accuracy. To evaluate compatibility with radiation therapy workflow, we evaluated device-induced CT imaging artifacts, US tracking performance during beam delivery, and device compatibility with commercial radiotherapy planning software. The RRUSS device produced 4D volumes at 0.1-3.0 Hz with 60 degrees lateral field of view (FOV), 50 degrees maximum elevational FOV, and 200 mm maximum depth. Imaging resolution (-3 dB point spread width) was 1.2-7.9 mm at depths up to 100 mm and motion tracking accuracy was <= 0.3 +/- 0.5 mm. No significant effect of the RRUSS device on CT image integrity was found, and RRUSS device performance was not affected by radiotherapy beam exposure. Agreement within +/- 3.0%/2.0 mm was achieved between computed and measured radiotherapy dose delivered directly through the RRUSS device at 6 MV and 15 MV. In vivo liver, kidney, and prostate images were successfully acquired. Our investigations suggest that a RRUSS device can offer non-interfering 4D guidance for radiation therapy and other diagnostic and therapeutic procedures.
引用
收藏
页码:2292 / 2300
页数:9
相关论文
共 19 条
  • [1] BABALOLA K, 2008, P 11 INT C MED IM CO, P409
  • [2] Monte Carlo modeling of ultrasound probes for image guided radiotherapy
    Bazalova-Carter, Magdalena
    Schlosser, Jeffrey
    Chen, Josephine
    Hristov, Dimitre
    [J]. MEDICAL PHYSICS, 2015, 42 (10) : 5745 - 5756
  • [3] In vivo reproducibility of robotic probe placement for a novel ultrasound-guided radiation therapy system
    Bell, Muyinatu A. Lediju
    Sen, H. Tutkun
    Iordachita, Iulian
    Kazanzides, Peter
    Wong, John
    [J]. JOURNAL OF MEDICAL IMAGING, 2014, 1 (02)
  • [4] Motion-Tracking Hardware and Advanced Applications in PET and PET/CT
    Bettinardi, V.
    De Bernardi, E.
    Presotto, L.
    Gilardi, M. C.
    [J]. PET CLINICS, 2013, 8 (01) : 11 - +
  • [5] Impact of probe pressure variability on prostate localization for ultrasound-based image-guided radiotherapy
    Fargier-Voiron, Marie
    Presles, Benoit
    Pommier, Pascal
    Rit, Simon
    Munoz, Alexandre
    Liebgott, Herve
    Sarrut, David
    Biston, Marie-Claude
    [J]. RADIOTHERAPY AND ONCOLOGY, 2014, 111 (01) : 132 - 137
  • [6] Three-dimensional ultrasound imaging
    Fenster, A
    Downey, DB
    Cardinal, HN
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (05) : R67 - R99
  • [7] Review of ultrasound image guidance in external beam radiotherapy: I. Treatment planning and inter-fraction motion management
    Fontanarosa, Davide
    van der Meer, Skadi
    Bamber, Jeffrey
    Harris, Emma
    O'Shea, Tuathan
    Verhaegen, Frank
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (03) : R77 - R114
  • [8] Effective dose estimates for cone beam computed tomography in interventional radiology
    Kwok, Y. M.
    Irani, F. G.
    Tay, K. H.
    Yang, C. C.
    Padre, C. G.
    Tan, B. S.
    [J]. EUROPEAN RADIOLOGY, 2013, 23 (11) : 3197 - 3204
  • [9] Lachaine M., 2013, Medical Physics International Journal, V1, P72, DOI DOI 10.1053/J.SEMRADONC.2003.10.003
  • [10] Organ motion and its management
    Langen, KM
    Jones, DTL
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 50 (01): : 265 - 278