Steady Flow in a Patient-Averaged Inferior Vena Cava-Part II: Computational Fluid Dynamics Verification and Validation

被引:27
|
作者
Craven, Brent A. [1 ]
Aycock, Kenneth I. [1 ]
Manning, Keefe B. [2 ]
机构
[1] US FDA, Div Appl Mech, Off Sci & Engn Labs, Ctr Devices & Radiol Hlth, Silver Spring, MD 20993 USA
[2] Penn State Univ, Dept Biomed Engn, University Pk, PA 16802 USA
关键词
Inferior vena cava; Hemodynamics; Computational fluid dynamics; Verification and validation; BLOOD-FLOW; QUANTIFICATION; HEMODYNAMICS; HELICITY; UNCERTAINTY; FILTERS;
D O I
10.1007/s13239-018-00392-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose-The embolus trapping performance of inferior vena cava (IVC) filters critically depends on how emboli flow through the IVC and, thereby, on the underlying hemodynamics. Most previous studies of IVC hemodynamics have used computational fluid dynamics (CFD), but few have validated their results by comparing with quantitative experimental measurements of the flow field and none have validated in an anatomical model of the IVC that includes the primary morphological features that influence the hemodynamics (iliac veins, infrarenal curvature, and non-circular vessel cross-section). In this study, we perform verification and validation of CFD simulations in a patient-averaged anatomical model of the IVC. Methods-Because we are most interested in the fluid dynamics that influence embolus transport and IVC filter embolus trapping, we focus our analyses on the velocity distribution and the amount of swirl and mixing in the infrarenal IVC. A rigorous mesh refinement study is first conducted at the highest flow rate condition to verify the computed solutions. To validate the CFD predictions of the flow patterns, we then compare with particle image velocimetry (PIV) data acquired in the same model in two planes (coronal and sagittal) within the infrarenal IVC at two flow rates corresponding to rest and exercise conditions. Results-Using unstructured hexahedral meshes ranging in size from 800,000 to 102.5 million computational cells, we demonstrate that a coarse mesh may be used to resolve the gross flow patterns and velocity distribution in the IVC. A finer mesh is, however, required to obtain asymptotic mesh convergence of swirl and mixing in the IVC, as quantified by the local normalized helicity, LNH, and the volume-averaged helicity intensity, HI. Based on the results of the mesh refinement study, we use a moderately fine mesh containing approximately 26 million cells for comparison with experimental data. The validation study demonstrates excellent qualitative agreement between CFD predictions and PIV measurements of the velocity field at both conditions. Quantitatively, we show that the global relative comparison error, E, between CFD and PIV ranges from 3 to 11%. By performing sensitivity studies, we demonstrate that the quantitative discrepancy is attributable to a combination of uncertainty in the inlet flow rates and uncertainty associated with precisely aligning the PIV data with the CFD geometry. Conclusions-Overall, the study demonstrates mesh-convergent CFD simulations that predict IVC flow patterns that agree reasonably well with PIV data, even at exercise conditions where the flow in the IVC is extremely complex.
引用
收藏
页码:654 / 673
页数:20
相关论文
共 20 条
  • [1] Steady Flow in a Patient-Averaged Inferior Vena Cava—Part II: Computational Fluid Dynamics Verification and Validation
    Brent A. Craven
    Kenneth I. Aycock
    Keefe B. Manning
    Cardiovascular Engineering and Technology, 2018, 9 : 654 - 673
  • [2] Steady Flow in a Patient-Averaged Inferior Vena Cava-Part I: Particle Image Velocimetry Measurements at Rest and Exercise Conditions
    Gallagher, Maureen B.
    Aycock, Kenneth I.
    Craven, Brent A.
    Manning, Keefe B.
    CARDIOVASCULAR ENGINEERING AND TECHNOLOGY, 2018, 9 (04) : 641 - 653
  • [3] Steady Flow in a Patient-Averaged Inferior Vena Cava—Part I: Particle Image Velocimetry Measurements at Rest and Exercise Conditions
    Maureen B. Gallagher
    Kenneth I. Aycock
    Brent A. Craven
    Keefe B. Manning
    Cardiovascular Engineering and Technology, 2018, 9 : 641 - 653
  • [4] Computational evaluation of inferior vena cava filters through computational fluid dynamics methods
    Rajan, Anand
    Makary, Mina S.
    Martyn, Thomas D.
    Dowell, Joshua D.
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2021, 27 (01) : 116 - 121
  • [5] COMPUTATIONAL FLUID DYNAMICS MODELING OF HEPATIC-PULMONARY BLOOD FLOW FOR FONTAN PLANNING IN PATIENTS WITH INTERRUPTED INFERIOR VENA CAVA
    Hoganson, David Monroe
    Govindarajan, Vijay
    Schulz, Noah E.
    Eickhoff, Emily R.
    Breitbart, Roger
    Marx, Gerald
    del Nido, Pedro
    Hammer, Peter
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2021, 77 (18) : 450 - 450
  • [6] Evaluation of hemodynamic effects of different inferior vena cava filter heads using computational fluid dynamics
    Li, Mingrui
    Wang, Jingying
    Huang, Wen
    Zhou, Yue
    Song, Xue
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2022, 10
  • [7] Hemodynamic analysis of fusiform-shaped inferior vena cava filter with thrombus capture: A computational fluid dynamics study
    Wang, Jingying
    Li, Mingrui
    Chen, Shuai
    Lee, Chunhian
    PHYSICS OF FLUIDS, 2025, 37 (03)
  • [8] Simulation study of hemodynamic commonality of umbrella-shaped inferior vena cava filter using computational fluid dynamics
    Li, Mingrui
    Song, Xue
    Wang, Jingying
    Zhou, Yue
    Zhang, Shiyue
    Lee, Chunhian
    PHYSICS OF FLUIDS, 2024, 36 (08)
  • [9] Verification and validation in computational fluid dynamics:: application to both steady and unsteady rowing boats numerical simulations
    Berton, M.
    Alessandrini, B.
    Barrie, S.
    Kobus, J. M.
    PROCEEDINGS OF THE SEVENTEENTH (2007) INTERNATIONAL OFFSHORE AND POLAR ENGINEERING CONFERENCE, VOL 1- 4, PROCEEDINGS, 2007, : 2006 - 2011
  • [10] Optimizing inferior vena cava filter design: A computational fluid dynamics study on strut configuration for enhanced hemodynamic performance and thrombosis reduction
    Kim, Byeong-Jun
    Lee, Chiseung
    HELIYON, 2024, 10 (11)