Application of Headspace Gas Chromatography with Flame Ionization Detector for Determination of Carboxyhemoglobin in Forensic Blood Samples

被引:0
作者
Le, Dinh-Vu [1 ]
Dang, Minh-Thu [2 ]
机构
[1] Ind Univ Ho Chi Minh City, Fac Chem Engn, Ho Chi Minh City 70000, Vietnam
[2] Forens Med Ctr Ho Chi Minh City, Ho Chi Minh City 70000, Vietnam
关键词
carbon monoxide; carboxyhemoglobin; headspace GC-FID; blood; forensic; CARBON-MONOXIDE;
D O I
10.1134/S1061934821120042
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The level of carboxyhemoglobin (CO-Hb) in the forensic blood sample is a critical evidence to the conclusion that the fatality was related to CO poisoning or other reason causing death. In this study, we validated the method for CO-Hb determination in blood using headspace gas chromatography-flame ionization detector (HS-GC/FID) for further application to the analysis of forensic samples. The liberated CO from CO-Hb was reduced to methane by a specific catalyst and then analyzed by GC-FID. The quantitative range for CO-Hb was from 2.5 to 100% with the limit of detection down to 0.5%. The average recovery at different levels of CO-Hb was from 96.8 to 98.5% with high repeatability and intermediate precision. The obtained parameters presented that the method was highly sensitive and accurate for CO-Hb determination in blood samples. The method was also applied to the analysis of 27 forensic samples that had the questionable cause of death. Eighteen samples were related to CO poisoning with the level of CO-Hb exceeding 15%. All the results demonstrated that this method could be applied for forensic diagnosis.
引用
收藏
页码:1430 / 1434
页数:5
相关论文
共 26 条
  • [21] Stability of blood carbon monoxide and hemoglobins during heating
    Seto, Y
    Kataoka, M
    Tsuge, K
    [J]. FORENSIC SCIENCE INTERNATIONAL, 2001, 121 (1-2) : 144 - 150
  • [22] Turn-on and Turn-off Fluorescent Probes for Carbon Monoxide Detection and Blood Carboxyhemoglobin Determination
    Shi, Genggongwo
    Yoon, Taeseung
    Cha, Seoncheol
    Kim, Seulgi
    Yousuf, Muhammad
    Ahmed, Nisar
    Kim, Doseok
    Kang, Hyun-Wook
    Kim, Kwang S.
    [J]. ACS SENSORS, 2018, 3 (06): : 1102 - 1108
  • [23] Carbon monoxide poisoning deaths in the United States, 1999 to 2012
    Sircar, Kanta
    Clower, Jacquelyn
    Shin, Mi Kyong
    Bailey, Cathy
    King, Michael
    Yip, Fuyuen
    [J]. AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2015, 33 (09) : 1140 - 1145
  • [24] Walch S.G., 2010, OPEN TOXICOLOGY J, V4, P21, DOI DOI 10.2174/1874340401004010021
  • [25] *WHO, 1999, INT PROGR CHEM SAF E
  • [26] The measurement of carboxyhemoglobin and methemoglobin using a non-invasive pulse CO-oximeter
    Zaouter, Cedrick
    Zavorsky, Gerald S.