Validation of In Vitro Cell-Based Human Blood Brain Barrier Model Using Clinical Positron Emission Tomography Radioligands To Predict In Vivo Human Brain Penetration

被引:22
|
作者
Mabondzo, Aloise [1 ]
Bottlaender, Michel [2 ]
Guyot, Anne-Cecile [1 ]
Tsaouin, Katya [3 ]
Deverre, Jean Robert [2 ]
Balimane, Praveen V. [4 ]
机构
[1] CEA, iBiTec S, Serv Pharmacol & Immunoanal, DSV, F-91191 Gif Sur Yvette, France
[2] CEA, Serv Hosp Frederic Joliot, DSV, I2BM, F-91406 Orsay, France
[3] APREDICA, Watertown, MA USA
[4] Bristol Myers Squibb Co, Princeton, NJ 08543 USA
关键词
Drug transport study; human blood brain barrier; in vivo in vitro correlation; positron emission tomography; NICOTINIC ACETYLCHOLINE-RECEPTORS; ENDOTHELIAL-CELLS; P-GLYCOPROTEIN; BENZODIAZEPINE-RECEPTORS; ABC TRANSPORTERS; C-11; FLUMAZENIL; PERMEABILITY; PET; QUANTIFICATION; LIGAND;
D O I
10.1021/mp1002366
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
We have evaluated a novel in vitro cell-based human blood brain barrier (BBB) model that could predict in vivo human brain penetration for compounds with different BBB permeabilities using the clinical positron emission tomography (PET) data. Comparison studies were also performed to demonstrate that the in vitro cell-based human BBB model resulted in better predictivity over the traditional permeability model in discovery organizations, Caco-2 cells. We evaluated the in vivo BBB permeability of [F-18] and [C-11]-compounds in humans by PET imaging. The in vivo plasma brain exchange parameters used for comparison were determined in humans by PET using a kinetic analysis of the radiotracer binding. For each radiotracer, the parameters were determined by fitting the brain kinetics of the radiotracer using a two-tissue compartment model of the ligand receptor interaction. Bidirectional transport studies with the same compounds as in in vivo studies were carried out using the in vitro cell-based human BBB model as well as Caco-2 cells. The in vitro cell-based human BBB model has important features of the BBB in vivo and is suitable for discriminating between CNS and non-CNS marketed drugs. A very good correlation (r(2) = 0.90; P < 0.001) was demonstrated between in vitro BBB permeability and in vivo permeability coefficient. In contrast, a poor correlation (r(2) = 0.17) was obtained between Caco-2 data and in vivo human brain penetration. This study highlights the potential of this in vitro cell-based human BBB model in drug discovery and shows that it can be an extremely effective screening tool for CNS programs.
引用
收藏
页码:1805 / 1815
页数:11
相关论文
共 50 条
  • [1] Evaluation of drug penetration into the brain:: A double study by in vivo Imaging with positron emission tomography and using an in vitro model of the human blood-brain barrier
    Josserand, V
    Pélerin, H
    de Bruin, B
    Jego, B
    Kuhnast, B
    Hinnen, F
    Ducongé, F
    Boisgard, R
    Beuvon, F
    Chassoux, F
    Daumas-Duport, C
    Ezan, E
    Dollé, F
    Mabondzo, A
    Tavitian, B
    JOURNAL OF PHARMACOLOGY AND EXPERIMENTAL THERAPEUTICS, 2006, 316 (01): : 79 - 86
  • [2] Brain penetration predictivity using in-vitro primary rat and human cell-based blood-brain barrier models for drug discovery and development
    Lacombe, O.
    Guyol, A. C.
    Videau, O.
    Pruvost, A.
    Bolze, S.
    Prevost, C.
    Mabondzo, A.
    FUNDAMENTAL & CLINICAL PHARMACOLOGY, 2010, 24 : 8 - 8
  • [3] Blood–Brain Barrier Penetration of Zolmitriptan—Modelling of Positron Emission Tomography Data
    Mats Bergström
    Roger Yates
    Anders Wall
    Matts Kågedal
    Stina Syvänen
    Bengt Långström
    Journal of Pharmacokinetics and Pharmacodynamics, 2006, 33 : 75 - 91
  • [4] Brain penetration of ebastine evaluated in human by positron emission tomography (PET)
    Tagawa, M
    Yanai, K
    Kano, M
    Okamura, N
    Higuchi, M
    Matsuda, M
    Mizuki, Y
    Iwata, R
    Arai, H
    Fujii, T
    Ido, T
    Itoh, M
    Sasaki, H
    Watanabe, T
    HISTAMINE RESEARCH IN THE NEW MILLENNIUM, 2001, 1224 : 137 - 146
  • [5] POSITRON EMISSION TOMOGRAPHY - EXAMINATION OF CHEMICAL TRANSMISSION IN THE LIVING HUMAN BRAIN - DEVELOPMENT OF RADIOLIGANDS
    FARDE, L
    HALL, H
    ARZNEIMITTEL-FORSCHUNG/DRUG RESEARCH, 1992, 42-1 (2A): : 260 - 264
  • [6] Cell-based models of blood-brain barrier penetration
    Vastag, Monika
    Hellinger, Eva
    Bakk, Monika L.
    Tihanyi, Karoly
    THERAPEUTIC DELIVERY, 2011, 2 (05) : 549 - 553
  • [7] Blood-brain barrier penetration of zolmitriptan -: Modelling of positron emission tomography data
    Bergström, M
    Yates, R
    Wall, A
    Kågedal, M
    Syvänen, S
    Långström, B
    JOURNAL OF PHARMACOKINETICS AND PHARMACODYNAMICS, 2006, 33 (01) : 75 - 91
  • [8] STUDIES ON BLOOD-BRAIN BARRIER TRANSPORT IN HUMAN-SUBJECTS USING POSITRON EMISSION TOMOGRAPHY (PET)
    BEANEY, RP
    BROOKS, DJ
    JONES, T
    LAMMERTSMA, AA
    MARSHALL, J
    THOMAS, DGT
    JOURNAL OF PHYSIOLOGY-LONDON, 1985, 360 (MAR): : P30 - P30
  • [9] Positron emission tomography of the human brain in an experimental itch model
    Darsow, U
    Drzezga, A
    Frisch, M
    Munz, F
    Weilke, F
    Bartenstein, P
    Schwaiger, M
    Ring, J
    INTERNATIONAL ARCHIVES OF ALLERGY AND IMMUNOLOGY, 2001, 124 (1-3) : 359 - 361
  • [10] Validation of an immortalized human (hBMEC) in vitro blood-brain barrier model
    Daniela Elisabeth Eigenmann
    Evelyn Andrea Jähne
    Martin Smieško
    Matthias Hamburger
    Mouhssin Oufir
    Analytical and Bioanalytical Chemistry, 2016, 408 : 2095 - 2107