Spectrophotometric Determination of Bromate in Water Using Multisyringe Flow Injection Analysis

被引:16
作者
Oliveira, Sara M. [1 ,2 ]
Segundo, Marcela A. [1 ]
Rangel, Antonio O. S. S. [2 ]
Lima, Jose L. F. C. [1 ]
Cerda, Victor [3 ]
机构
[1] Univ Porto, Fac Farm, Dept Quim, REQUIMTE, P-4099030 Porto, Portugal
[2] Univ Catolica Portuguesa, CBQF Escola Super Biotecnol, Porto, Portugal
[3] Univ Balearic Isl, Dept Chem, Palma de Mallorca, Spain
关键词
Bromate; Multisyringe flow injection analysis; Phenothiazines; Spectrophotometry; Water; ION-CHROMATOGRAPHIC METHOD; DRINKING WATERS; TRACE BROMATE; PHENOTHIAZINES; SEPARATION; BUFFER;
D O I
10.1080/00032719.2010.500771
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A multisyringe flow injection system for the spectrophotometric determination of bromate in water is proposed, based on the oxidation of phenothiazine compounds by bromate in acidic medium. Several phenothiazines were tested, including chlorpromazine, trifluoperazine, and thioridazine. Higher sensitivity and lower LOD were attained for chlorpromazine. Interference from nitrite, hypochlorite, and chlorite was eliminated in-line, without any changes in the manifold. The automatic methodology using chlorpromazine allowed the determination of bromate between 25 and 750 mu gL-1, with LOD of 6 mu gL-1, good precision (RSD1.6%, n=10), and determination frequency of 35h-1.
引用
收藏
页码:284 / 297
页数:14
相关论文
共 27 条
  • [1] Development of new methodologies for on-line determination of the bromate ion in samples of water subjected to ozonation treatment
    Almendral, Maria-Jesus
    Alonso, Angel
    Fuentes, Maria-Socorro
    [J]. JOURNAL OF ENVIRONMENTAL MONITORING, 2009, 11 (07): : 1381 - 1388
  • [2] Online Monitoring of Bromate in Ozonized Water Without a Previous Separation Process
    Almendral-Parra, M. J.
    Alonso-Mateos, A.
    Fuentes-Prieto, M. S.
    [J]. JOURNAL OF FLUORESCENCE, 2008, 18 (06) : 1169 - 1179
  • [3] Sequential and simultaneous determination of bromate and chlorite (DBPs) by flow techniques - Kinetic differentiation
    Alonso-Mateos, A.
    Almendral-Parra, M. J.
    Fuentes-Prieto, M. S.
    [J]. TALANTA, 2008, 76 (04) : 892 - 898
  • [4] [Anonymous], 1998, Federal Register, V63, P69390
  • [5] Flow techniques in water analysis
    Cerdà, V
    Estela, JM
    Forteza, R
    Cladera, A
    Becerra, E
    Altimira, P
    Sitjar, P
    [J]. TALANTA, 1999, 50 (04) : 695 - 705
  • [6] CHEN XG, 1990, ANAL LETT, V23, P119
  • [7] da Silva JCGE, 2001, ANAL CHIM ACTA, V450, P175
  • [8] A critical examination of the components of the Schlieren effect in flow analysis
    Dias, ACB
    Borges, EP
    Zagatto, EAG
    Worsfold, PJ
    [J]. TALANTA, 2006, 68 (04) : 1076 - 1082
  • [9] *EC, 1998, OFFICIAL J EUROPEAN, V32
  • [10] On-line separation and determination of bromate in drinking waters using flow injection ICP mass spectrometry
    Elwaer, AR
    McLeod, CW
    Thompson, KC
    [J]. ANALYTICAL CHEMISTRY, 2000, 72 (22) : 5725 - 5730