Three-dimensional dose verification in complex particle radiation fields based on X-ray films

被引:12
作者
Spielberger, B [1 ]
Krämer, M [1 ]
Scholz, M [1 ]
Kraft, G [1 ]
机构
[1] GSI, D-64291 Darmstadt, Germany
关键词
heavy ions; radiation dosimetry; film dosimetry; X-ray film; photographic emulsions;
D O I
10.1016/S0168-583X(02)02012-8
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In the framework of the heavy ion therapy at GSI a three-dimensional dose verification with films is performed. Due to the complex composition of the irradiation field, the knowledge of the film response depending on particle energy and atomic number is essential. Basic experiments were performed to investigate the response of films to heavy ion irradiation. Moreover a model was developed to calculate the respective film response and a look-up table of film responses for the therapy relevant particle and energy spectrum was established. This look-up table allows to calculate the expected optical density distribution of an exposed film. A three-dimensional dose verification with an array of films was yielded by comparing the calculated with the measured optical density distribution of the exposed films. These experiments were performed at the GSI facility using a carbon ion beam. The irradiated field shape was mapped perfectly by the films due to their high spatial resolution. Moreover, the applied physical dose distribution was quantitatively verified with high precision in three dimensions. (C) 2002 Elsevier B.V. All rights reserved.
引用
收藏
页码:277 / 282
页数:6
相关论文
共 9 条
[1]  
BATHELT B, 2000, THESIS U GHK KASSEL
[2]   A dosimetry system for fast measurement of 3D depth-dose profiles in charged-particle tumor therapy with scanning techniques [J].
Brusasco, C ;
Voss, B ;
Schardt, D ;
Krämer, M ;
Kraft, G .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2000, 168 (04) :578-592
[3]   Verification of heavy ion dose distributions using thermoluminescent detectors [J].
Geiss, OB ;
Krämer, M ;
Kraft, G .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1998, 146 (1-4) :541-544
[4]   MAGNETIC SCANNING SYSTEM FOR HEAVY-ION THERAPY [J].
HABERER, T ;
BECHER, W ;
SCHARDT, D ;
KRAFT, G .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 330 (1-2) :296-305
[5]   Tumortherapy with ion beams [J].
Kraft, G .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 454 (01) :1-10
[6]   Treatment planning for heavy-ion radiotherapy:: physical beam model and dose optimization [J].
Krämer, M ;
Jäkel, O ;
Haberer, T ;
Kraft, G ;
Schardt, D ;
Weber, U .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (11) :3299-3317
[7]  
SCHOLZ M, 1994, RADIAT PROT DOSIM, V52, P29
[8]   Calculation of the x-ray film response to heavy charged particle irradiation [J].
Spielberger, B ;
Scholz, M ;
Krämer, M ;
Kraft, G .
PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (22) :4107-4120
[9]   Experimental investigations of the response of films to heavy-ion irradiation [J].
Spielberger, B ;
Scholz, M ;
Krämer, M ;
Kraft, G .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (11) :2889-2897