Efficient electrocatalysis of L-cysteine oxidation at carbon ionic liquid electrode

被引:125
作者
Maleki, N. [1 ]
Safavi, A. [1 ]
Sedaghati, F. [1 ]
Tajabadi, F. [1 ]
机构
[1] Shiraz Univ, Coll Sci, Dept Chem, Shiraz 71454, Fars, Iran
关键词
L-cysteine; CILE; electrocatalysis; soya milk;
D O I
10.1016/j.ab.2007.04.024
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The electrochemistry Of L-cysteine (CySH) in neutral aqueous media was investigated using carbon ionic liquid electrode (CILE). Comparative experiments were carried out using glassy carbon electrodes. At CILE, highly reproducible and well-defined cyclic voltammograms were obtained for L-cysteine with a peak potential of 0.49 V vs Ag/AgCl, showing that CILE manifests a good electrocatalytic activity toward oxidation Of L-cysteine. A linear dynamic range of 2-210 mu M with an experimental detection limit of 2 mu M was obtained. The method was successfully applied to the determination of L-cysteine in a sample of soya milk. Cysteine oxidation at CILE does not result in deactivation of the electrode surface. Mechanistic studies showed that, at CILE, the overall CySH oxidation is controlled by the oxidation of the CyS- electroactive species. (c) 2007 Elsevier Inc. All rights reserved.
引用
收藏
页码:149 / 153
页数:5
相关论文
共 17 条
[1]   A primer on electro catalysis [J].
Bockris, JOM .
JOURNAL OF THE SERBIAN CHEMICAL SOCIETY, 2005, 70 (03) :475-487
[2]   AN ELECTROCHEMICAL STUDY OF OXIDATION OF L-CYSTEINE [J].
DAVIS, DG ;
BIANCO, E .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1966, 12 (03) :254-&
[3]   Electrochemical behavior Of L-cysteine and its detection at carbon nanotube electrode modified with platinum [J].
Fei, SD ;
Chen, JH ;
Yao, SZ ;
Deng, GH ;
He, DL ;
Kuang, YF .
ANALYTICAL BIOCHEMISTRY, 2005, 339 (01) :29-35
[4]   Effect of the counterion on thermodynamic properties of aqueous micellar solutions of 1-(3,3,4,4,5,5,6,6,6-nonafluorohexyl) pyridinium halides .1. Apparent and partial molar enthalpies and volumes at 298 K [J].
Fisicaro, E ;
Ghiozzi, A ;
Pelizzetti, E ;
Viscardi, G ;
Quagliotto, PL .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 1996, 182 (02) :549-557
[5]   ELECTROCATALYTIC AND ANALYTICAL RESPONSE OF COBALT PHTHALOCYANINE CONTAINING CARBON PASTE ELECTRODES TOWARD SULFHYDRYL COMPOUNDS [J].
HALBERT, MK ;
BALDWIN, RP .
ANALYTICAL CHEMISTRY, 1985, 57 (03) :591-595
[6]   Preparation of novel mercury-doped silver nanoparticles film glassy carbon electrode and its application for electrochemical biosensor [J].
Li, MG ;
Shang, YJ ;
Gao, YC ;
Wang, GF ;
Fang, B .
ANALYTICAL BIOCHEMISTRY, 2005, 341 (01) :52-57
[7]  
LIU TY, 1977, PROTEINS, V3, pCH3
[8]   High-performance carbon composite electrode based on an ionic liquid as a binder [J].
Maleki, Norouz ;
Safavi, Afsaneh ;
Tajabadi, Fariba .
ANALYTICAL CHEMISTRY, 2006, 78 (11) :3820-3826
[9]   THE ELECTROCHEMISTRY OF L-CYSTINE AND L-CYSTEINE .1. THERMODYNAMIC AND KINETIC-STUDIES [J].
RALPH, TR ;
HITCHMAN, ML ;
MILLINGTON, JP ;
WALSH, FC .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1994, 375 (1-2) :1-15
[10]   Ionic liquids modify the performance of carbon based potentiometric sensors [J].
Safavi, Afsaneh ;
Maleki, Norouz ;
Honarasa, Fatemeh ;
Tajabadi, Fariba ;
Sedaghatpour, Fatemeh .
ELECTROANALYSIS, 2007, 19 (05) :582-586