A new protocol for wear testing of total knee prostheses from real joint kinematic data: Towards a scenario of realistic simulations of daily living activities

被引:17
作者
Abdel-Jaber, Sami [1 ]
Belvedere, Claudio [2 ]
De Mattia, Jonathan Salvatore [1 ]
Leardini, Alberto [2 ]
Affatato, Saverio [1 ]
机构
[1] Rizzoli Ortopaed Inst, Med Technol Lab, Via Barbiano 1-10, I-40136 Bologna, Italy
[2] Rizzoli Ortopaed Inst, Movement Anal Lab, Bologna, Italy
关键词
Total knee arthroplasty; Highly demanding daily activities; Video-fluoroscopy; Knee wear simulator; Stair climbing; Chair sitting; Chair rising; Squat; IN-VIVO KINEMATICS; CROSS-LINKED POLYETHYLENE; TIBIAL INSERT; STAIR ASCENT; VITRO WEAR; ARTHROPLASTY; REPLACEMENT; SURFACE; KINETICS; CONCAVE;
D O I
10.1016/j.jbiomech.2016.07.003
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A new tendency in the field of wear testing of total knee replacements is represented by realistic simulations of various motor tasks of daily living (chair sitting and rising, squat, stair ascent, etc.). Various studies have shown in fact the limits of the ISO 14243 standards, in particular the concern about the ability of the level walking simulations to recreate the main wear mechanisms which occur on the knee implant during its in vivo lifespan. The recently proposed protocols for the simulation of these motor tasks still lack accuracy and consistency between the various degrees of freedom, which are necessary for a good replication of the mechanical behavior in a replaced knee. In the present study a realistic scenario for simulation of various motor tasks using a displacement controlled wear testing machine is presented. Stair climbing, chair sit/stand cycle, and squat cycle were analyzed through video-fluoroscopy in a population of knee replacement patients to extract flexion/extension and intra/extra rotation angles, together with anterior/posterior translation. Corresponding axial load data were arranged by gait analysis from a control population. The proposed protocol was tested on a displacement controlled wear simulator. Kinematic and load data revealed good consistency across subjects. The knee simulator showed an accurate reproduction of the various motion and load patterns, with average error lower than 5%. The obtained dataset for wear simulator, containing all the displacement and loading parameters for stair climbing, chair sit/stand and squat activities, is fully reported. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2925 / 2931
页数:7
相关论文
共 52 条
[1]  
Abdel Jaber S., 2014, INT ORTHOP
[2]  
Abdel-Jaber S., 2015, J BIOMECH
[3]   Unicompartmental knee prostheses:: in vitro wear assessment of the menisci tibial insert after two different fixation methods [J].
Affatato, S. ;
Spinelli, M. ;
Zavalloni, M. ;
Carmignato, S. ;
Lopomo, N. ;
Marcacci, M. ;
Viceconti, M. .
PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (19) :5357-5369
[4]   Investigation on wear of knee prostheses under fixed kinematic conditions [J].
Affatato, Saverio ;
Leardini, Walther ;
Rocchi, Mirko ;
Toni, Aldo ;
Viceconti, Marco .
ARTIFICIAL ORGANS, 2008, 32 (01) :13-18
[5]  
[Anonymous], 2009, 142432 ISO DIS
[6]  
[Anonymous], 2004, 1424314243 ISO DIS
[7]   Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopy [J].
Banks, SA ;
Hodge, WA .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1996, 43 (06) :638-649
[8]   A new protocol from real joint motion data for wear simulation in total knee arthroplasty: Stair climbing [J].
Battaglia, Santina ;
Belvedere, Claudio ;
Jaber, Sami Abdel ;
Affatato, Saverio ;
D'Angeli, Valentina ;
Leardini, Alberto .
MEDICAL ENGINEERING & PHYSICS, 2014, 36 (12) :1605-1610
[9]   Three-dimensional motion analysis of the human knee joint: comparison between intra- and post-operative measurements [J].
Belvedere, C. ;
Tamarri, S. ;
Notarangelo, D. P. ;
Ensini, A. ;
Feliciangeli, A. ;
Leardini, A. .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2013, 21 (10) :2375-2383
[10]   Material and surface factors influencing backside fretting wear in total knee replacement tibial components [J].
Billi, Fabrizio ;
Sangiorgio, Sophia N. ;
Aust, Sarah ;
Ebramzadeh, Edward .
JOURNAL OF BIOMECHANICS, 2010, 43 (07) :1310-1315